In this case, coding is activated using a system security key that differs
from the one supplied with the product.
To reset the actuator, you will have to use the conguration software for
resetting the central control unit. The procedure to follow is
described in the manual for the central control unit software.
10 Response to power recovery
The instructions below describe how the device responds to a power
failure (or disconnection from the mains) and the failure of the battery.
When the operating voltage is switched on (recovery of mains voltage),
the actuator checks its components. If an error is detected, all channel
LEDs will ash. This is repeated continuously and the device does not
perform its function. If the test is completed without errors, the actuator
transmits a wireless telegram containing its status information. To pre-
vent all actuators transmitting at the same time when power is recove-
red, there is a random delay before the actuator transmits. During this
time, the channel LEDs ash (as in teach-in mode). If the delay is very
short, this ashing may be almost
imperceptible.
11 Channel LED feedback
11.1 Channel LED ashing codes
Various actuator states are indicated by the channel LEDs ashing:
Slow ashing Teach-in mode
Fast ashing Reset
One long ash, n brief ashes (depending
on the type of error)
Error
Long on, short off Corresponding output
activated with