Operation Manual

33
11.2 Operating status display
As soon as a switching output is active, the corresponding channel LED
will light up continuously; if the switch-off timer is active, the LED will
ash.
Once the actuator has been congured using the central control unit or a
programming tool, the LED will indicate other device states in addition to
those already described.
More detailed information can be found in the conguration manual and
the system manual for the control unit.
11.3 Power supply status display
Various power supply states are indicated by the device’s green
“Power” LED:
Continuously lit Mains voltage present, battery OK
Flashing 1 x No mains voltage
Flashing 2 x Battery fault
Flashing 3 x Battery empty
OFF
Device faulty or mains voltage and battery
missing
If several errors are pending, the error with the least number of ashing
sequences will be displayed.
12 Notes about the battery
A functioning battery is absolutely essential to the operation of the
radio-controlled alarm siren and ash actuator.
To provide protection against deep discharge of the battery, the
device’s switching outputs are deactivated when the battery is emp-
ty.
It takes up to 30 hours to charge an empty battery.
Under certain circumstances, a very discharged battery can be