HS-LS100+ Z-Wave Leak Sensor
Applicaons
• Use to acvate Z-Wave devices such as sirens or water valve controllers when a leak is sensed.
• Use to trigger home automaon events (aka “scenes”, “automaons” or “robots”) when a leak is sensed.
Conguraon
HS-LS100+ is baery powered and includes a Z-Wave network buon, LED indicator and a magnec wall mount/wired probe
assembly. The unit may be deployed as a free-standing sensor (using built-in probes) or as a wired remote sensor (via the wall
mount/wired probe assembly).
Z-Wave Network Installaon
Remove the back cover by rotang counter-clockwise and install 1 ER14250 baery (included) inside HS-LS100+. Include the
sensor into your Z-Wave network using the instrucons below. Then, replace the back cover.
Note: HS-LS100+ may be included into your Z-Wave network as a “secure” device or as a “non-secure” device. Use the
instrucons below to include or exclude HS-LS100+ to/from your Z-Wave network.
Secure Inclusion (recommended if your home controller supports “S0” or “S2” Z-Wave encrypon)
1. Put your home controller into Z-Wave ‘inclusion’ mode.
2. Press and hold the Z-Wave network buon for 5 seconds, then release it. Wait for the inclusion process to nish.
Non-Secure Inclusion
1. Put your home controller into Z-Wave ‘inclusion’ mode.
2. Quickly press and release the Z-Wave network buon once. Wait for the inclusion process to nish.
Exclusion
1. Put your home automaon controller into Z-Wave ‘exclusion’ mode.
2. Quickly triple-press the Z-Wave network buon. Wait for the exclusion process to nish.
Reset (Use this procedure to reset HS-LS100+ to factory sengs when the Z-Wave controller is missing or inoperable).
1. Press and hold the Z-Wave buon for 20 seconds. Release the buon once the LED stops blinking and glows solidly.
Physical Installaon
Free-standing installaon: Simply place the leak sensor on a at horizontal surface in the area where a leak might occur.
Remote installaon: Install the included magnec wall mount/wired probe assembly in the locaon of your choice (using the
supplied mounng hardware) and aach the HS-LS100+ to it by aligning the 3 probes with the 3 holes in the mounng bracket.
Posion and install the wired probe in the area where a leak might occur or where you wish to detect liquid.
Leak Sensor Operaon
HS-LS100+ is designed to transmit a Z-Wave command when liquid is sensed. It will also transmit another command when
liquid is no longer sensed.
Shock Sensor Operaon
The shock sensor is designed to transmit a Z-Wave command when HS-LS100+ has been physically moved. This sensor is
especially helpful in determining whether the unit has been removed from its mount or tampered with.
OVERVIEW
HS-LS100+ is a compact, easy to install leak sensor. It is designed to control other Z-Wave devices directly or it may be used
with a variety of Z-Wave cered home controllers to launch automaon events or scenes.