ADVANCED CONFIGURATION (accessible via the Root devicein a HomeSeer System. Before adjusng these sengs, tap the
network buon 4 mes to wake the unit.)
Parameter Sengs Parameter Sengs
14
Enable / Disable Basic Set Command
Available: 0=disable, 1=enable
Default: 0 | Size: 1 byte
20
Set High Temperature Trigger Value
Available: -670 to 2570 (-67 to 257 °F)
Default: 1040 (104 °F) | Size: 2 bytes
15
Set Value for Basic Set Command
Available: 0=Sends 255 value when leak sensed
Available: 1=Sends 0 value when leak sensed
Default: 0 | Size: 1 byte
22
Set Low Temperature Trigger Value
Available: -670 to 2570 (-67 to 257 °F)
Default: 320 (32 °F) | Size: 2 bytes
17
Leak Report Interval
Available: 0=disable, 1 to 255 (minutes)
Default: 5 | Size: 1 byte
24
Enable Blinking LED When Alarm Triggers
Available: 0=disable, 1=enable
Default: 1 | Size: 1 byte
18
Enable Shock Sensor
Available: 0=disable, 1=enable
Default: 0 | Size: 1 byte
32
Set Value for Low Baery
Available: 10-50 (%)
Default: 20 (%) | Size: 1 byte
19
Temperature Report Interval
Available: 0=disable, 1 to 255 (minutes)
Default: 0 | Size: 1 byte
Note: Parameter 18 (“Enable Shock Sensor”) and parameter 19
(“Temperature Report Interval) are disabled by default, to
conserve baery life.
LIMITED WARRANTY
HomeSeer Technologies, LLC will repair or replace, at its opon, any part of the device, which proves to be defecve in workmanship or
material under normal use, in the USA except in the states of Alaska or Hawaii, for a period of one year from the date the device is
purchased. During the warranty period, HomeSeer Technologies, LLC will repair and provide all parts necessary to correct such defects, free
of charge, provided the device has been operated in accordance with the manufacturer's guidelines. The Customer will return the device to
HomeSeer Technologies, LLC for tesng and repair or replacement. Should you need service, during warranty period or beyond, contact
HomeSeer to obtain return authorizaon before shipping your device to HomeSeer Technologies, LLC.
SPECIFICATIONS
Operang Temp Range 0ºC to 40ºC Power Requires (1) ER14250 Baery
Z-Wave Frequency | Range
Z-Wave Cercaon
908 MHz (US) | Up To 300 Ft line of sight
Z-Wave Plus
Dimensions Sensor (main unit): 2.75 x 2.75 x .75 (inches)
Baery Sensor Operaon
The baery sensor is designed to report baery level with a Z-Wave command every 43200 seconds (12 hours). If desired,
HomeSeer users can adjust this interval (0-2678400 seconds) by accessing the sengs on the Z-Wave tab of the root device.
Z-Wave Associaon Informaon
HS-LS100+ supports Group 1 associaon. Group 1 reports the sensors status and baery if running on baeries.
Notes
If your home controller supports S2security encrypon, the Leak Sensor may be added as a securedevice to your
network. If not, it will add as a non-secure device. This will not eect the funconality of the unit.
For more informaon, visit homeseer.com.