Outdoor IOT Gateway Installation Guide 1
WARNING: MUST not install or remove GPS, LoRa or LTE Antenna when DC power is applied to the Gateway. It may damage the device. For un-connected N Type Antenna Port, MUST install a " N Type Connector Cap" to prevent water getting into the device.
Our mounting bracket design will be able to fix in two different locations, which is antenna pole and wall. Mounting bracket is also be able to fix in two direction, Vertical and Horizontal as well. Bracket fix in the gateway for first step 1. On Wall locking the expansion nail for bracket. (Maximum 40Kg.cm torque for M5 nuts.
After locking the nuts, Reverse 3~4 turns nuts on wall. Hang on the IOT gateway then locking the nuts again.
2. On a Pole (Maximum 55Kg.
Due to IoT Gateway has been certified with IP67 that SI can install with no any waterproof protection. But We still recommend that insert 3M 2166 waterproofing tape on antenna port could enhance reliability and prevent intentionally destroy in field.
3. DHCP Setup WARNING: MUST not install or remove GPS, LoRa or LTE Antenna when DC power is applied to the Gateway. It may damage the device.
4.
Hardware Specification: Item Technical Information WiFi IEEE 802.11 b/g/n 2.4 GHz GPS 1575.42 MHz Ethernet 100/1000 Mbps DC PWR Max 60W, POE 802.3af compliant Power Consumption 40W max Antenna 2 N-type external LoRA antenna 1 N-type external LTE antenna 1 N-type external active GPS antenna IP Code IP67 UV Resistance 0.77 w/m2 @340nm Operation Temperature &Humidity -20~70 ℃, 20% ~90% Dimension 269 × 184 × 85 mm Weight 2.4 kg MAX Regulatory FCC LoRaWAN 1.0 (GW2.
Software Specification: Item Technical Information Backhaul Connection Ethernet / LTE / WiFi VPN OpenVPN / Strongswan LoRa GW Application LoRa packet forward, uplink/downlink FW upgrade Remote Server side FW upgrade / Local GUI upgrade Link Monitor Healthy status report Configuration Preserved in Flash Backup & restore / dynamic & permanent setting / Reset to default Web/GUI Setup / Status report ThingPark LRR integration LoRa packet forwarding LoRa location without GPS (MCG022E) Use Diff
Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.