User's Manual

REV. 0.0
8
3. Software Requirements
Follow the requirements of [1].
4. Regulatory requirements
Suitable protection devices in compliance with IEC 61000-4-5 class 3 at
least or FCC part 68 shall be provided on the line interfaces, the POTS
splitter/ Low-pass filter, and AC power supply lines to safeguard the unit
against the damage due to transient and lightning surge voltage
presented on the telephone line and AC power supply line. The test
results of IEC 61000-4-5 can be temporary degradation or loss of function
or performance but must be self-recoverable and pass operationally within
10 minutes. To fulfill surge protection in easy-installation manner, the
ATU-R must incorporate with chassis grounding mechanism on the
exterior of device.
The electromagnetic compatibility requirements of the ATU-R shall comply
with class A of EN55022 of the CENELEC (the European Committee for
Electrotechnical Standardization), or class A of 22 of the CISPR
(International Special Committee on Radio Interference of the
International Electrotechnical Commission) or class A of Subpart B of Part
15 of the FCC (Federal Communications Commission) rules of U.S.A.