DC application
The DC
terminals may be used for charging 12 volt automotive-type batteries
only.
m Batteries produce explosive gases.
Keep
sparks, flames, and
cigarettes away. To prevent the possibility of creating .a spark near the
battery, connect charging cables first to the battery,
then to the generator,
and disconnect cables first at the generator.
CAUTION:
l
Do not attempt to start an automobile engine with the generator still
connected to the battery. The generator may be damaged.
l
Connect the positive battery terminal to the positive generator terminal. Do
not reverse the charging cables, or serious damage to the generator and/or
battery may occur.
NOTE:
l
The DC terminals may be used while the AC power is in use.
l
An overloaded DC circuit will trip the DC circuit protector (push button
comes out). If this happens, wait a few minutes
before
pushing the circuit
protector to resume operation.