- Honda Generator Owner's Manual

45
STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO
PREVENT HARD STARTING
Before storing the unit for an extended period:
1. Be sure the storage area is free of excessive humidity and dust.
2. Service according to the table below:
Less than 1 month
1 to 2 months
2 months to 1 year
1 year or more
Use gasoline conditioners that are formulated to extend storage
life.
Contact your authorized Honda generator dealer for conditioner
recommendations.
No preparation required
Fill with fresh gasoline and add gasoline
conditioner *.
Fill with fresh gasoline and add gasoline
conditioner *.
Drain the carburetor float bowl. (page 46 ).
Drain the fuel sediment cup. (page 40 ).
Fill with fresh gasoline and add gasoline
conditioner *.
Drain the carburetor float bowl. (page 46 ).
Drain the fuel sediment cup. (page 40 ).
Remove the spark plug. Put a tablespoon of
engine oil into the cylinder. Turn the engine
slowly with the recoil starter to distribute the
oil. Reinstall the spark plug.
Change the engine oil. (page 38 ).
After removal from storage, drain the stored
gasoline into a suitable container, and fill
with fresh gasoline before starting.
*
03/11/17 18:45:08 31Z21600_046