- Honda Portable Generator Owner's Manual

SPARK ARRESTER MAINTENANCE
If the generator has been running, the muffler
will
be very hot. Allow
it
to cool before proceeding.
The spark arrester must be serviced every
100
hours to maintain its
efficiency.
1.
Remove the two
8
mm nuts
0,
and remove the muffler
@
from
the
cylinder.
2.
Remove the six
5
mm
screws
@
from the muffler protector
@
,
and
remove the muffler protector.
3.
Remove the
4
mm screw
@
from the spark arrester
0
,
and remove
the spark arrester from the muffler.
4.
Use
a
brush to remove carbon deposits from the spark arrester
screen.
5.
Inspect the spark arrester for breaks or holes, and replace
it
if
necessary.
6.
Install the spark arrester and the muffler in the reverse order of
disassembly.
SPARKARRESTER
SCREEN
37