- Honda Portable Generator Owner's Manual

8. TRANSPORTING/STORAGE
m When transporting the generator, turn the engine switch
dFF
and keep the generator level to prevent fuel spillage. Fuel vapor or spilled
fuel may ignite.
Before storing the unit for an extended period:
1. Be sure the storage area is’ free of excessive humidity and dust.
2. Drain the fuel-
a. Open the rear maintenance cov-
er.
b. Turn the engine switch to ON
and then loosen the carburetor
drain screw. Drain the gasoline
DRAIN SCREW
from the carburetor and fuel
tank into a suitable container.
wtm
Gasoline is extreme-
ly flammable and is explosive
under certain conditions. Per-
form this task in a well ven-
tilated area with the engine
stopped. Do not smoke or allow
flames or s,parks in the area dur-
ing this procedure.
c. Tighten the carburetor drain
screw, turn the engine switch to
OFF and close the rear mainte-
nance cover.
d. Drain the fuel sediment cup (see
page 26).
3. Change the engine oil.
4. Remove the spark plug, and pour about a tablespoon of clean engine oil
into the cylinder. Crank the engine several revolutions to distribute the
oil, then reinstall the spark plug.
5. Cover the generator to keep out dust.
6. Once a month, recharge the battery.
NOTE: When starting ttie generator after adding fuel for the first time, after
long-term storage, or after running
out
of fuel turn the engine switch to the
“ON” position, then wait for 10 to 20 seconds before starting the engine.
30