User Guide

AC APPLICATIONS
Before connecting an appliance or power cord to the generator:
Make sure that it
is
in good working order. Faulty appliances or
power cords can create
a
potential for electrical shock.
If an appliance begins to operate abnormally, becomes sluggish or
stops suddenly, turn
it
off
immediately. Disconnect the appliance,
and determine whether the problem is the appliance, or if the rated
load capacity of the generator has been exceeded.
Make sure that the electrical rating of the tool or appliance does not
exceed that of the generator. Never exceed the maximum power
rating of the generator. Power levels between rated and maximum
may be used for no more than
30
minutes.
WI
Substantial overloading may switch
off
the AC circuit breaker.
Exceeding the time limit for maximum power operation or slightly
overloading the generator may not switch the AC circuit breaker
OFF,
but
will
shorten the service life of the generator.
Limit operation requiring maximum power to
30
minutes.
Maximum output
is:
10.5
kVA
For continuous operation, do not exceed the rated power.
Rated output
is:
9.5
kVA
The total power requirements (VA) of
all
appliances connected must
be considered. Appliance and power tool manufacturers usually
list
rating information near the model number or serial number.
23