- Honda Portable Generator Owner's Manual

Generator Indicator Light
The generator indicator light comes on and the engine Will stop
automatically when there is a problem with the generator or the rated load
capacity of the generator has been exceeded.
If this occurs:
l
,Turn the engine switch to the “OFF” position.
l
Disconnect the appliance from the generator.
l
Reset the AC circuit breaker or circuit protector.
l
Start the engine (see page 21) and observe the generator warning light:
-
If the light does not come on, plug the apppliance in and check to see
if the light comes on. If the light comes on and the engine stops
automatically, check the appliance for proper operation or exceeding
the rated load capacity of the circuit.
-
If the light comes on after the engine has been restarted and the
engine stops automatically, discontinue operation of the generator
and contact an authorized Honda generator dealer.
GENERATOR INDICATOR LIGHT
CHARGE INDICATOR LIGHT
Charge Indicator Light
The charge indicator light comes on and the engine is stopped
automatically when there is a problem in the battery charging system.
If this occurs:
l
Turn the engine switch to the OFF position.
l
Start the engine (see page 21).
l
If the engine stops again automatically, determine when the charge in-
dicator light comes on:
-
If the light comes on immediately when the engine stops, the pro-
blem is the charging system. Stop using the generator and contact
an authorized Honda generator dealer.
-
If the engine stops automatically and the charge indicator light
comes on approximately 15 seconds after the engine stops, the pro-
blem is either in the fuel system (see page 15) or a problem with the
engine. See your authorized Honda generator dealer if the charge in-
12
dicator light comes on even though there is sufficient fuel.