- Honda Generator Owner's Manual

14
Circuit Breaker
GFCI RESET BUTTON
CIRCUIT BREAKER
ON
OFF
Check the following if the circuit breaker switches OFF automatically:
The circuit breaker will automatically switch OFF if there is a short
circuit or a significant overload of the generator at the receptacle, or if
the ground fault circuit interrupter (GFCI) detects a ground fault
current.
When the GFCI RESET button is extended (page 18):
The circuit breaker may be used to switch the generator power on or
off.
Check that the appliance is working properly and does not exceed
the rated load capacity of the circuit before switching the circuit
breaker ON again.
When the GFCI RESET button is not extended:
Unplug all appliances from the receptacles and check the
appliance for any defects as described in TROUBLESHOOTING
(page 48).
After making repairs, push the GFCI RESET button then turn the
circuit breaker ON.