12. INSTALLATION OF OPTIONAL PARTS
Remote control kit
The generator may be adapted for remote control operation by use of an
optional kit.
1. Unscrew the two 6 x 10 mm flange bolts and 6 x 8 mm screws attaching
the control panel. Remove the control panel.
6 x 10 mm FLANGE BOLTS
2. Position the relay box on the back of the control panel with the studs
inserted through the holes in the relay box flange. Install a 4 mm nut and
lock washer on each stud and tighten securely.
3. Remove the 6-P coupler with a jumper wire from the wire harness female
coupler. Connect the relay box 6-P male coupler to the wire harness female
coupler.
4. Insert the relay box 6-P female coupler in the hole in the sub panel below
the control panel and install with the two self-tapping screws and coupler
holder.
4 x 10 mm SELF-
TAPPING SCREWS
CONTROL
COUPLER HOLDER
HOLE IN SUB PANEL
31
4 mm’NUT