- Honda Car Owner's Manual
48
STARTING/RESTARTINGMODE
Energyflowfrombatterytogasengine(viaelectricmotor)
Undermostconditions,theInsightengineisstartedbytheIMAmotor,whichinstantlyspinstheengine
to1000rpm.
TheInsightalsohasaconventional12vauxiliarystartermotorthatisusedinthefollowingsituations:
• ThestateofchargeoftheBatteryModuleistoolow.
• Theambienttemperatureistoohighortoolow.
• ThereisafailureoftheIMAsystem.
BecausetheInsightwon'tenteridlestopmodeinanyoftheabovesituations,allenginestartsother
thantheinitialstartwillalwaysbedoneusingtheIMAmotor.
To testthe12v auxiliarystartingsystem,firstdisabletheIMAstartingsystembyremovingfuse#2
fromtheunder-dashfusebox.