AC OPERATION
If an appliance begins to operate abnormally, becomes sluggish, or
stops suddenly, turn it off immediately
. Disconnect the appliance, and
determine whether the problem is in the appliance or the rated load
capacity of the generator has been exceeded.
Substantial overloading may damage the generator. Marginal
overloading may shorten the service life of the generator.
1. Start the engine (see page 29).
2. Switch ON the AC circuit breaker.
3. Plug in the appliance.
Most motorized appliances require more than their rated wattage for
star
tup.
Do not ex
ceed the current limit specified for any of the receptacles.
If an overloaded circuit causes the AC circuit breaker or AC circuit
protector to
switch OFF
, reduce the electrical load on the circuit, wait a
few minutes and then reset the AC circuit breaker or AC circuit protector.
Before connecting an appliance to the generator, make sure that it is
in good order and that its ele
ctrical rating does not exceed that of the
generator. Then start the generator and connect the appliance power
cord.
AC CIRCUIT BREAKER
ON