Operation Manual

66
STORAGE
Service according to the table below:
STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO
PREVENT HARD STARTING
Less than 1 month No p
reparation required
1 to 2 months
Fill with fresh gasoline and add gasoline
sta
bilizer*.
2 months to 1 year
Fill with fresh gasoline and add gasoline
sta
bilizer*.
Drain the carburetor float bowl
(see page 67).
Drain the fuel sediment cup (see page 54).
1 year or more
Fill with fresh gasoline and add gasoline
s
ta
bilizer*.
Drain the carburetor float bowl
(see page 67).
Drain the fuel sediment cup (see page 54).
Remove the spark plug. Put a teaspoon of
engine oil into each cylinder. Turn the
engine
for a few seconds by turning the
engine switch to the START position to
distribute the oil in the cylinders. Reinstall
the spark plug.
Change the engine oil (see page 49).
After removal from storage, drain the stored
gasoline into a sui
table container, and fill
with fresh gasoline before starting.
*Use gasoline stabilizers that are formulated to extend storage life.
Follow the manufacture
r’s instructions for use.
Contact your authorized Honda generator dealer for stabilizer
recommendations.
31Z266100.book 66 ページ 2014年12月5日 金曜日 午後5時7分