Inspection :
1. Remove the battery cell caps.
2. Inspect the electrolyte level of
each cell. The electrolyte level
must be maintained between the
UPPER and LOWER limit marks.
3. If the electrolyte level is near the
LOWER mark, add distilled
water as necessary.
UPPER LIMIT
LOWER LIMIT
The battery contains sulfuric acid (electrolyte) which is highly
corrosive and poisonous.
Getting electrolyte in your eyes or on your skin can cause serious
bums.
Wear protective clothing and eye protection when working near
the battery.
EMERGENCY PROCEDURES:
Eyes- Flush with water from a cup or other container for at least 15
minutes (water under pressure can damage the eye), Immediately call
a physician, local poison control, or 91 1.
Skin- Remove contaminated clothing. Flush the skin with large
quantities of water. Call a physician immediately.
Swallowing - Drink water or milk. Call your local poison control center
or a physician immediately.