User's Manual

TRANSPORTING/STORAGE
When transporting the generator, turn the engine switch and the fuel
valve OFF. Keep the generator level to preventfuel spillage. Fuel
vapor or spilled fuel may ignite.
If the engine has been running, allow it to cool for at least 15 minutes
before loading the generator on the transport vehicle or placing it in
storage. A hot engine and exhaust system can bum you and can ignite
some materials.
Take care not to drop or strike the generator when transporting. Do
not place heavy objects on the generator.
Before storing the unit for an extended period:
1. Be sure the storage area is free of excessive humidity and dust.
2. Service according to the table below:
STORAGE TIME
Less than 1 month
1 to 2 months
2 months to 1 year
1 year or more
RECOMMENDED SERVICE PROCEDURE TO
PREVENT HARD STARTING
No preparation required
Fill with fresh gasoline and add gasoline
conditioner*.
Fill with fresh gasoline and add’ gasoline
conditioner*.
Drain the carburetor float bowl (page 52).
Drain the fuel sediment cup (page 45).
Fill with fresh gasoline and add gasoline
conditioner*.
Drain the carburetor float bowl (page 52).
Drain the fuel sediment cup (page 45).
Remove the spark plugs. Pour
a
tablespoon (5 - 10
cc) of clean engine oil into each cylinder. Using the
electric starter, crank the engine a few revolutions to
distribute the oil in the cylinders. Reinstall the spark
plugs.
Change the engine oil (page 37).
After removal from storage, drain the stored gaso-
line into a suitable container, and fill with fresh
1 gasoline before starting.
* Use gasoline conditioners that are formulated to extend storage life.
Contact your authorized Honda generator dealer for conditioner recommendations.
51