Owner’s Manual GENERATOR EB2000i Click to Save As 31Z39801 00X31-Z39-8010 AH Hi FM Printed in Thailand C 2013 Honda Motor Co., Ltd.
< HO ࡍࠫ 㧞㧜㧝㧠ᐕ㧝㧝㧢ᣣᦐᧁޓᣣޓඦ೨㧝㧜ᤨ㧠㧢ಽ < HO ࡍࠫ 㧞㧜㧝㧠ᐕ㧝㧝㧢ᣣᦐᧁޓᣣޓඦ೨㧝㧜ᤨ㧠㧥ಽ QUICK REFERENCE INFORMATION Fuel The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
1Z398000.book 1 ページ 2013年8月1日 木曜日 午後4時36分 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased with your purchase of one of the finest generators on the market. We want to help you get the best results from your new generator and to operate it safely. This manual contains all the information on how to do that; please read it carefully. As you read this manual, you will find information preceded by a symbol.
31Z398000.book 2 ページ 2013年8月1日 木曜日 午後4時36分 A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important. And using this generator safely is an important responsibility. To help you make informed decisions about safety, we have provided operating procedures and other information on labels and in this manual. This information alerts you to potential hazards that could hurt you or others.
31Z398000.book 3 ページ 2013年8月1日 木曜日 午後4時36分 CONTENTS GENERATOR SAFETY ................................................................. 6 IMPORTANT SAFETY INFORMATION ........................................ 6 Operator Responsibility ......................................................... 6 Carbon Monoxide Hazards ..................................................... 6 Electric Shock Hazards.......................................................... 7 Fire and Burn Hazards ...............................
31Z398000.book 4 ページ 2013年8月1日 木曜日 午後4時36分 CONTENTS OPERATION ............................................................................. 21 SAFE OPERATING PRECAUTIONS ........................................... 21 STARTING THE ENGINE ......................................................... 22 STOPPING THE ENGINE ......................................................... 25 GFCI OPERATION CHECK ....................................................... 26 AC OPERATION .....................................
31Z398000.book 5 ページ 2013年8月1日 木曜日 午後4時36分 CONTENTS TRANSPORTING ...................................................................... 56 TAKING CARE OF UNEXPECTED PROBLEMS ............................... 57 ENGINE WILL NOT START ...................................................... 57 ENGINE LACKS POWER ......................................................... 58 NO POWER AT THE AC RECEPTACLES ................................... 58 TECHNICAL INFORMATION ................................................
31Z398000.book 6 ページ 2013年8月1日 木曜日 午後4時36分 GENERATOR SAFETY IMPORTANT SAFETY INFORMATION Honda generators are designed for use with electrical equipment that has suitable power requirements. Other uses can result in injury to the operator or damage to the generator and other property. Most injuries or property damage can be prevented if you follow all instructions in this manual and on the generator. The most common hazards are discussed below, along with the best way to protect yourself and others.
31Z398010-01.fm 7 ページ 2014年6月2日 月曜日 午後1時11分 GENERATOR SAFETY To alert you to potentially dangerous levels of carbon monoxide coming from a generator operating outside or from other sources, install battery operated carbon monoxide alarms or plug-in carbon monoxide alarms with battery back-up on every level of the home and outside sleeping areas, according to the manufacturer’s instructions.
31Z398000.book 8 ページ 2013年8月1日 木曜日 午後4時36分 GENERATOR SAFETY SAFETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda servicing dealer for a replacement.
31Z398000.
31Z398000.book 10 ページ 2013年8月1日 木曜日 午後4時36分 CONTROLS & FEATURES COMPONENT & CONTROL LOCATIONS Use the illustrations on these pages to locate and identify the most frequently used controls.
31Z398000.
31Z398000.book 12 ページ 2013年8月1日 木曜日 午後4時36分 CONTROLS & FEATURES CONTROLS Engine Switch The engine switch controls the ignition system and the fuel valve. ENGINE SWITCH ON OFF – Stops the engine and closes the fuel valve. ON – Running position; opens the fuel valve and allows the engine to be started. OFF Starter Grip Pulling the starter grip operates the recoil starter to start the engine. Do not allow the starter grip to snap back against the generator.
31Z398000.book 13 ページ 2013年8月1日 木曜日 午後4時36分 CONTROLS & FEATURES Fuel Filler Cap Vent Lever The fuel filler cap is provided with a fuel filler cap vent lever to seal the fuel tank. The fuel filler cap vent lever must be in the ON position for the engine to run. When the engine is not in use, leave the fuel filler cap vent lever in the OFF position to reduce the possibility of fuel leakage. Allow the engine to cool before turning the fuel filler cap vent lever to the OFF position.
31Z398010-01.fm 14 ページ 2014年6月2日 月曜日 午後1時11分 CONTROLS & FEATURES Eco-Throttle™ Switch The Eco-Throttle™ system automatically reduces engine speed when loads are turned off or disconnected. When appliances are turned on or reconnected, the engine returns to the proper speed to power the electrical load. If high electrical loads are connected simultaneously, turn the Eco-Throttle switch to the OFF position to reduce voltage changes.
31Z398010-01.fm 15 ページ 2014年5月15日 木曜日 午後8時24分 CONTROLS & FEATURES Ground Fault Circuit Interrupter (GFCI) Receptacle The 120 V 20 A duplex receptacle is protected by a Ground Fault Circuit Interrupter (GFCI) for protection against the shock hazard of ground fault currents. The GFCI Receptacle has a TEST and RESET button.
31Z398000.book 16 ページ 2013年8月1日 木曜日 午後4時36分 CONTROLS & FEATURES FEATURES Ground Terminal The generator ground terminal is connected to the frame of the generator, the metal non-current-carrying parts of the generator, and the ground terminals of each receptacle. Before using the ground terminal, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.
31Z398000.book 17 ページ 2013年8月1日 木曜日 午後4時36分 CONTROLS & FEATURES Output Indicator The output indicator (green) is illuminated when the generator is operating normally. It indicates that the generator is producing electrical power at the receptacles. In addition, the output indicator has a simplified hour meter function.
31Z398000.book 18 ページ 2013年8月1日 木曜日 午後4時36分 CONTROLS & FEATURES Overload Indicator If the generator is overloaded (in excess of 2.0 kVA), or if there is a short circuit in a connected appliance, the overload indicator (red) will come ON. The overload indicator (red) will stay ON, and after about four seconds, current to the connected appliance(s) will shut off, and the output indicator (green) will go OFF. However, the engine will continue to run.
31Z398000.book 19 ページ 2013年8月1日 木曜日 午後4時36分 BEFORE OPERATION ARE YOU READY TO GET STARTED? Your safety is your responsibility. A little time spent in preparation will significantly reduce your risk of injury. Knowledge Read and understand this manual. Know what the controls do and how to operate them. Familiarize yourself with the generator and its operation before you begin using it. Know how to quickly shut off the generator in case of an emergency.
31Z398000.book 20 ページ 2013年8月1日 木曜日 午後4時36分 BEFORE OPERATION To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from building walls and other equipment during operation. Do not place flammable objects close to the engine. Before beginning your pre-operation checks, be sure the generator is on a level and firm surface and the engine switch is in the OFF position. Check the Engine • Before each use, look around and underneath the engine for signs of oil or gasoline leaks.
31Z398000.book 21 ページ 2013年8月1日 木曜日 午後4時36分 OPERATION SAFE OPERATING PRECAUTIONS Before operating the generator for the first time, review chapters GENERATOR SAFETY (see page 6) and BEFORE OPERATION (see page 19). For your safety, do not operate the generator in an enclosed area such as a garage. Your generator’s exhaust contains poisonous carbon monoxide gas that can collect rapidly in an enclosed area and cause illness or death.
31Z398000.book 22 ページ 2013年8月1日 木曜日 午後4時36分 OPERATION STARTING THE ENGINE To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from building walls and other equipment during operation. Do not place flammable objects close to the engine. • Operating this generator less than 3 feet (1 meter) from a building or other obstruction can cause overheating and damage the generator. • For proper cooling, allow at least 3 feet (1 meter) of empty space above and around the generator.
31Z398000.book 23 ページ 2013年8月1日 木曜日 午後4時36分 OPERATION 3.Make sure the Eco-Throttle switch is in the OFF position, or more time will be required for warm-up. ECO-THROTTLE SWITCH 4.To start a cold engine, move the choke lever to the CLOSED position. To restart a warm engine, leave the choke lever in the OPEN position. OFF CHOKE LEVER OPEN CLOSED 5.Turn the engine switch to the ON position.
31Z398000.book 24 ページ 2013年8月1日 木曜日 午後4時36分 OPERATION 6.Pull the starter grip lightly until you feel resistance; then pull briskly in the direction of the arrow as shown. Direction to pull Do not allow the starter grip to snap back against the generator. Return it gently to prevent damage to the starter. STARTER GRIP 7.If the choke lever was moved to the CLOSED position to start the engine, gradually move it to the OPEN position as the engine warms up. CHOKE LEVER OPEN CLOSED 8.
31Z398000.book 25 ページ 2013年8月1日 木曜日 午後4時36分 OPERATION STOPPING THE ENGINE To stop the engine in an emergency, simply turn the engine switch to the OFF position. Under normal conditions, use the following procedure. 1.Turn off or disconnect all appliances that are connected to the generator. 2.Turn the engine switch to the OFF position. ENGINE SWITCH OFF 3.Allow the engine to cool, and then turn the fuel filler cap vent lever to the OFF position.
31Z398000.book 26 ページ 2013年8月1日 木曜日 午後4時36分 OPERATION GFCI OPERATION CHECK Always check GFCI operation before using the generator. A faulty GFCI can cause electric shock which can seriously injury or kill you. Always perform the GFCI inspection before using the generator. If the GFCI fails the test, the generator must be repaired by an authorized Honda servicing dealer before use. 1.Unplug all tools and appliances from the generator. 2.Start the engine (see page 22). 3.
31Z398000.book 27 ページ 2013年8月1日 木曜日 午後4時36分 OPERATION 4.Press the RESET button: • The RESET button should be flush with the base. • If the RESET button is not flush with the TEST button, contact an authorized Honda generator dealer. • The LED is lit during normal operation. • The LED is not lit if there is a fault current or during a GFCI test. • The LED is not lit if the GFCI is faulty. Contact an authorized Honda generator dealer. When the RESET button extends during operation.
31Z398000.book 28 ページ 2013年8月1日 木曜日 午後4時36分 OPERATION AC OPERATION Before connecting an appliance to the generator, make sure that it is in good working order and that its electrical rating does not exceed that of the generator. Most motorized appliances require more than their electrical rating for startup. When an electric motor is started, the overload alarm indicator (red) may come ON. This is normal if the overload alarm indicator (red) goes OFF within 4 seconds.
Z398000.book 29 ページ 2013年8月1日 木曜日 午後4時36分 OPERATION 2.Plug the appliance into the receptacle. 3.Turn on the appliance. If the generator is overloaded (see page 30), or if there is a short circuit in a connected appliance, the overload alarm indicator (red) will go ON. The overload alarm indicator (red) will stay ON, and after about four seconds, current to the connected appliance(s) will shut off, and the output indicator (green) will go OFF. Stop the engine and investigate the problem.
31Z398010-01.fm 30 ページ 2014年6月2日 月曜日 午後3時18分 OPERATION AC Applications Before connecting an appliance or power cord to the generator: • Make sure that it is in good working order. A faulty appliance or power cord can create a potential for electrical shock. • If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is the appliance or the rated load capacity of the generator has been exceeded.
31Z398010-01.fm 31 ページ 2014年6月2日 月曜日 午後1時11分 OPERATION ECO-THROTTLE™ SYSTEM With the switch in the ON position, engine speed is automatically lowered when loads are reduced, turned off, or disconnected. When appliances are turned ON or reconnected, the engine returns to the proper speed to power the electrical load. In the OFF position, the Eco-Throttle™ system does not operate.
31Z398010-01.fm 32 ページ 2014年6月2日 月曜日 午後1時11分 OPERATION STANDBY POWER Connections to a Building’s Electrical System Do not connect an EB2000i generator to a home or building's electrical system. The Honda EB2000i generator is designed for construction job site use and cannot be connected to a building's electrical system. This generator has the neutral bonded to ground to comply with OSHA job site temporary power regulation.
31Z398000.book 33 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR THE IMPORTANCE OF MAINTENANCE Good maintenance is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. To help you properly care for your generator, the following pages include a maintenance schedule, routine inspection procedures, and simple maintenance procedures using basic hand tools.
31Z398000.book 34 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR MAINTENANCE SAFETY Some of the most important safety precautions follow. However, we cannot warn you of every conceivable hazard that can arise in performing maintenance. Only you can decide whether or not you should perform a given task. Failure to properly follow maintenance instructions and precautions can cause you to be seriously hurt or killed. Always follow the procedures and precautions in the owner’s manual.
31Z398000.book 35 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR MAINTENANCE SCHEDULE REGULAR SERVICE PERIOD (3) Perform at every indicated month or operating hour interval, whichever comes first.
31Z398000.book 36 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR REFUELING With the engine stopped, remove the fuel filler cap and check the fuel level. Refill the fuel tank if the fuel level is low. Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. • Stop the engine and keep heat, sparks, and flame away. • Handle fuel only outdoors. • Wipe up spills immediately. Fuel can damage paint and plastic.
31Z398000.book 37 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR FUEL FILLER CAP UPPER LEVEL MARK (RED) TETHER FUEL FILTER After refueling, tighten the fuel filler cap until it clicks.
31Z398000.book 38 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR FUEL RECOMMENDATIONS This engine is certified to operate on regular unleaded gasoline with a pump octane rating of 86 or higher. Never use stale or contaminated gasoline or an oil/gasoline mixture. Avoid getting dirt or water in the fuel tank. You may use regular unleaded gasoline containing no more than 10% ethanol (E10) or 5% methanol by volume. In addition, methanol must contain cosolvents and corrosion inhibitors.
31Z398000.book 39 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR ENGINE OIL LEVEL CHECK Check the engine oil level with the generator on a level surface and the engine stopped. 1.Loosen the maintenance cover screw and remove the maintenance cover.
31Z398000.book 40 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR 2.Remove the oil filler cap. 3.Check the oil level. If it is below the upper limit, fill with the recommended oil to the upper limit of the oil filler neck (see page 42). 4.Reinstall the oil filler cap securely. 5.Reinstall the maintenance cover and tighten the maintenance cover screw securely.
31Z398000.book 41 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR ENGINE OIL CHANGE Drain the oil while the engine is warm to assure rapid and complete draining. 1.Turn the engine switch and fuel filler cap vent lever to the OFF position (see page 25) to reduce the possibility of fuel leakage. 2.Loosen the maintenance cover screw and remove the maintenance cover (see page 39). 3.Place a suitable container next to the engine to catch the used oil. 4.
31Z398000.book 42 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR ENGINE OIL RECOMMENDATIONS Oil is a major factor affecting performance and service life. Use 4-stroke automotive detergent oil. SAE 10W–30 is recommended for general use. Other viscosities shown in the chart may be used when the average temperature in your area is within the recommended range. AMBIENT TEMPERATURE The SAE oil viscosity and service category are in the API label on the oil container.
31Z398000.book 43 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR AIR CLEANER SERVICE 1.Loosen the maintenance cover screw and remove the maintenance cover. 2.Loosen the air cleaner cover screw, and remove the air cleaner cover. 3.Remove the main and outer filters from the air cleaner case. MAINTENANCE COVER SCREW MAINTENANCE COVER AIR CLEANER CASE MAIN FILTER AIR CLEANER COVER SCREW OUTER FILTER AIR CLEANER COVER 4.
31Z398000.book 44 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR 5.Reinstall the air filters. AIR CLEANER COVER 6.Make sure that the rubber seal is set in the groove of the air cleaner cover. 7.Reinstall the air cleaner cover, and tighten the air cleaner cover screw. 8.Reinstall the maintenance cover, and tighten the maintenance cover screw securely.
31Z398010-01.fm 45 ページ 2014年5月15日 木曜日 午後8時24分 SERVICING YOUR GENERATOR MAIN AND OUTER FILTERS CLEANING Dirty main and outer filters will restrict air flow to the carburetor, reducing engine performance. If you operate the generator in very dusty areas, clean the main and outer filters more frequently than specified in the MAINTENANCE SCHEDULE (see page 35). 1. Clean the air filters in warm soapy water, rinse, and allow to dry thoroughly, or clean in nonflammable solvent and allow to dry. 2.
31Z398000.book 46 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR SPARK PLUG SERVICE In order to service the spark plug, you will need a spark plug wrench (commercially available). Recommended spark plug: CR5HSB (NGK) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. An incorrect spark plug can cause engine damage. If the engine is hot, allow it to cool before servicing the spark plug. 1.Remove the spark plug maintenance cover. 2.
31Z398000.book 47 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR 5.Inspect the spark plug. Replace it if the electrodes are worn or if the insulator is cracked, chipped, or fouled. 6.Measure the spark plug electrode gap with a wire-type feeler gauge. Correct the gap, if necessary, by carefully bending the side electrode. SIDE ELECTRODE SEALING WASHER 0.024–0.028 in (0.6–0.7 mm) INSULATOR The gap should be: 0.024–0.028 in (0.6–0.7 mm) 7.
31Z398000.book 48 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR SPARK ARRESTER SERVICE The spark arrester must be serviced every 100 hours to keep it functioning as designed. If the engine has been running, the muffler will be very hot. Allow the muffler to cool before servicing the spark arrester. Clean the spark arrester as follows: 1.Remove the four 6 mm screws, and remove the muffler protector. MUFFLER PROTECTOR 6 mm SCREWS 2.
31Z398000.book 49 ページ 2013年8月1日 木曜日 午後4時36分 SERVICING YOUR GENERATOR 3.Use a brush to remove carbon deposits from the spark arrester screen. Be careful to avoid damaging the screen. The spark arrester must be free of breaks and tears. Replace the spark arrester if it is damaged. 4.Check the muffler gasket; replace if damaged. Reinstall the muffler gasket, the spark arrester, the muffler, and the muffler protector in the reverse order of removal.
31Z398000.book 50 ページ 2013年8月1日 木曜日 午後4時36分 STORAGE STORAGE PREPARATION Proper storage preparation is essential for keeping your generator trouble-free and looking good. The following steps will help to keep rust and corrosion from impairing your generator’s function and appearance, and will make the engine easier to start when you use the generator again. Cleaning Wipe the generator with a moist cloth.
31Z398000.book 51 ページ 2013年8月1日 木曜日 午後4時36分 STORAGE Service according to the table below: STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required. 1 to 2 months Fill with fresh gasoline and add gasoline stabilizer*. 2 months to 1 year Fill with fresh gasoline and add gasoline stabilizer*. Turn the engine switch to the OFF position and drain the carburetor float bowl (see page 52).
31Z398000.book 52 ページ 2013年8月1日 木曜日 午後4時36分 STORAGE Draining the Carburetor Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. • Stop the engine and keep heat, sparks, and flame away. • Handle fuel only outdoors. • Wipe up spills immediately. 1.Loosen the maintenance cover screw and remove the maintenance cover (see page 39). 2.Loosen the carburetor drain screw, and drain the gasoline from the carburetor into a suitable container. 3.
31Z398000.book 53 ページ 2013年8月1日 木曜日 午後4時36分 STORAGE Draining the Fuel Tank and Carburetor Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. • Stop the engine and keep heat, sparks, and flame away. • Handle fuel only outdoors. • Wipe up spills immediately. 1.Unscrew the fuel filler cap (see page 37), remove the fuel filter, and empty the fuel tank into an approved gasoline container.
31Z398000.book 54 ページ 2013年8月1日 木曜日 午後4時36分 STORAGE Engine Oil 1.Change the engine oil (see page 41). 2.Remove the spark plug (see page 46), and pour approximately one teaspoon (5 cc) of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil, and then reinstall the spark plug. 3.Reinstall the spark plug cap on the spark plug securely. 4.Reinstall the spark plug maintenance cover. 5.Reinstall the maintenance cover and tighten the maintenance cover screw securely. 6.
31Z398000.book 55 ページ 2013年8月1日 木曜日 午後4時36分 STORAGE STORAGE PRECAUTIONS If your generator will be stored with gasoline in the fuel tank and carburetor, it is important to reduce the hazard of gasoline vapor ignition. Select a well ventilated storage area away from any appliance that operates with a flame, such as a furnace, water heater, or clothes dryer. Also avoid any area with a spark-producing electric motor, or where power tools are operated.
31Z398000.book 56 ページ 2013年8月1日 木曜日 午後4時36分 TRANSPORTING Do not lay the generator on its side when moving, storing, or operating it. Oil may leak and damage the engine or your property. If the generator has been used, allow it cool for at least 15 minutes before loading the generator on the transport vehicle. A hot engine and exhaust system can burn you and can ignite some material.
31Z398000.book 57 ページ 2013年8月1日 木曜日 午後4時36分 TAKING CARE OF UNEXPECTED PROBLEMS ENGINE WILL NOT START Possible Cause Fuel filler cap vent lever is in the OFF position. Engine switch is in the OFF position. Out of fuel. Bad fuel, generator stored without treating or draining gasoline, or refueled with bad gasoline. Low engine oil level caused Oil Alert to stop engine. Correction Turn the fuel filler cap vent lever to the ON position (see page 22). Turn engine switch to the ON position (see page 23).
31Z398000.book 58 ページ 2013年8月1日 木曜日 午後4時36分 TAKING CARE OF UNEXPECTED PROBLEMS ENGINE LACKS POWER Possible Cause Air filters restricted. Correction Clean or replace air filters (see page 43). Bad fuel, generator stored without Drain fuel tank and carburetor (see page 53). treating or draining gasoline, or refueled with bad gasoline. Refuel with fresh gasoline (see page 36).
31Z398000.book 59 ページ 2013年8月1日 木曜日 午後4時36分 TECHNICAL INFORMATION Serial Number Location FRAME SERIAL NUMBER Record the frame serial number and date purchased in the spaces below. You will need this information when ordering parts and when making technical or warranty inquiries.
31Z398000.book 60 ページ 2013年8月1日 木曜日 午後4時36分 TECHNICAL INFORMATION Carburetor Modification for High Altitude Operation At high altitude, the standard carburetor air-fuel mixture will be too rich. Performance will decrease, and fuel consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting. Operation at an altitude that differs from that at which this engine was certified, for extended periods of time, may increase emissions.
31Z398000.book 61 ページ 2013年8月1日 木曜日 午後4時36分 TECHNICAL INFORMATION Emission Control System Information Source of Emissions The combustion process produces carbon monoxide, oxides of nitrogen, and hydrocarbons. Control of hydrocarbons and oxides of nitrogen is very important because, under certain conditions, they react to form photochemical smog when subjected to sunlight. Carbon monoxide does not react in the same way, but it is toxic.
31Z398000.book 62 ページ 2013年8月1日 木曜日 午後4時36分 TECHNICAL INFORMATION Problems That May Affect Emissions If you are aware of any of the following symptoms, have your engine inspected and repaired by your authorized Honda servicing dealer. • Hard starting or stalling after starting. • Rough idle. • Misfiring or backfiring under load. • Afterburning (backfiring). • Black exhaust smoke or high fuel consumption.
31Z398000.book 63 ページ 2013年8月1日 木曜日 午後4時36分 TECHNICAL INFORMATION Air Index (Models certified for sale in California) An Air Index Information label is applied to engines certified to an emission durability time period in accordance with the requirements of the California Air Resources Board. The bar graph is intended to provide you, our customer, the ability to compare the emissions performance of available engines. The lower the Air Index, the less pollution.
31Z398000.book 64 ページ 2013年8月1日 木曜日 午後4時36分 TECHNICAL INFORMATION Specifications Dimensions Model Description code Length Width Height Dry mass [weight] EB2000i EAET 20.2 in (512 mm) 11.4 in (290 mm) 16.7 in (425 mm) 45.6 lbs (20.7 kg) Engine Model Engine type Displacement [Bore×Stroke] Compression ratio Engine speed Cooling system Ignition system Engine oil capacity Fuel tank capacity Spark plug GX100 4-stroke, overhead camshaft, single cylinder 6.01 cu-in (98.5 cm3) [2.20×1.57 in (56.0×40.0 mm)] 8.
SPARK PLUG Bu ENGINE GROUND Bl/Bu P Gr W IGNITION ENGINE PULSER GROUND COIL COIL EXCITER WINDING SUB WINDING MAIN WINDING Bl G R W Bu Gr P INVERTER BLOCK OIL LEVEL SWITCH Y R Bu G INVERTER UNIT W R Y Bu THROTTLE CONTROL MOTOR W R Y Bu GENERATOR BLOCK G ENGINE BLOCK GROUND Bl/Bu Bu G Y R/W R/Y G/R G/Bl R W GFCI ECOTHROTTLE Bl/Bu Bu G Y W R OFF ON ON OFF Switch position Bl G Bl Bl/Bu Bu R/W G/R G/Bl Y G AC RECEPTACLES G BLACK YELLOW BLUE GREEN RED WHITE Br O Lb Lg
31Z398000.book 66 ページ 2013年8月1日 木曜日 午後4時36分 CONSUMER INFORMATION Dealer Locator Information To find an authorized Honda Servicing Dealer anywhere in the United States: Visit our website: http://powerequipment.honda.com/dealer-locator Honda Publications Shop Manual This manual covers complete maintenance and overhaul procedures. It is intended to be used by a skilled technician. Available through your Honda dealer or visit http://powerequipment.honda.
31Z398000.book 67 ページ 2013年8月1日 木曜日 午後4時36分 CONSUMER INFORMATION Customer Service Information Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership’s management. The Service Manager or General Manager can help. Almost all problems are solved in this way.
31Z398000.book 68 ページ 2013年8月1日 木曜日 午後4時36分 CONSUMER INFORMATION Distributor’s Limited Warranty This warranty is limited to the following Honda Power Equipment products when distributed by American Honda Motor Co., Inc., Power Equipment Division, 4900 Marconi Drive, Alpharetta, Georgia 30005-8847. The following warranty applies to products purchased at retail or placed in rental service on or after January 1, 2010.
31Z398000.book 69 ページ 2013年8月1日 木曜日 午後4時36分 CONSUMER INFORMATION To Obtain Warranty Service: You must, at your expense, take the Honda Power Equipment product, accessory, replacement part, apparel, or the power equipment on which the accessory or replacement part is installed, and proof of purchase to any Honda Power Equipment dealer in the United States, Puerto Rico, or the U.S. Virgin Islands who is authorized to sell that product, during the dealer’s normal business hours.
31Z398000.book 70 ページ 2013年8月1日 木曜日 午後4時36分 CONSUMER INFORMATION Exclusions: 1.
31Z398000.book 71 ページ 2013年8月1日 木曜日 午後4時36分 CONSUMER INFORMATION Honda Accessories, Replacement Parts, And Apparel This warranty is limited to Honda Power Equipment parts, accessories, and apparel when distributed by American Honda Motor Co., Inc., 4900 Marconi Drive, Alpharetta, Georgia 30005-8847.
31Z398000.book 72 ページ 2013年8月1日 木曜日 午後4時36分 CONSUMER INFORMATION To Obtain Warranty Service: You must, at your expense, take the Honda Power Equipment accessory, replacement part, apparel, or the Honda Power Equipment on which the accessory or replacement part is installed, and proof of purchase to any Honda Power Equipment dealer, distributor, or distributor’s dealer in the United States, Puerto Rico, or the U.S.
31Z398000.book 73 ページ 2013年8月1日 木曜日 午後4時36分 CONSUMER INFORMATION Emission Control System Warranty Your new Honda Power Equipment engine complies with the U.S. EPA, Environment Canada, and State of California emission regulations (models certified for sale in California only). American Honda Motor Co., Inc. provides the emission warranty coverage for engines in the United States, and its territories. Honda Canada Inc.
31Z398000.book 74 ページ 2013年8月1日 木曜日 午後4時36分 CONSUMER INFORMATION Owner’s Warranty Responsibility: As the power equipment engine owner, you are responsible for the performance of the required maintenance listed in your owner’s manual. Honda recommends that you retain all receipts covering maintenance on your power equipment engine, but Honda cannot deny warranty coverage solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance.
31Z398000.book 75 ページ 2013年8月1日 木曜日 午後4時36分 CONSUMER INFORMATION Warranty Coverage: Honda power equipment engines sold in the United States and Canada are covered by this warranty for a period of two years from the date of delivery to the original retail purchaser or the length of the Honda Distributor’s Limited Warranty, whichever is longer. This warranty is transferable to each subsequent purchaser for the duration of the warranty period.
31Z398000.book 76 ページ 2013年8月1日 木曜日 午後4時36分 CONSUMER INFORMATION To Obtain Warranty Service: You must, at your own expense, take your Honda Power Equipment engine or the product on which it is installed, along with your sales registration card or other proof of original purchase date, to any Honda Power Equipment dealer who is authorized by Honda to sell and service that Honda product during his normal business hours.
31Z398000.book 77 ページ 2013年8月1日 木曜日 午後4時36分 CONSUMER INFORMATION Disclaimer of Consequential Damage and Limitation of Implied Warranties: American Honda Motor Co., Inc. and Honda Canada Inc. disclaim any responsibility for incidental or consequential damages such as loss of time or the use of the power equipment, or any commercial loss due to the failure of the equipment; and any implied warranties are limited to the duration of this written warranty.
31Z398000.book 78 ページ 2013年8月1日 木曜日 午後4時36分 INITIAL USE INSTRUCTIONS ENGINE OIL The generator is shipped WITHOUT OIL in the engine. 1.Place the generator on a level surface. 2.Loosen the maintenance cover screw and remove the maintenance cover. MAINTENANCE COVER SCREW MAINTENANCE COVER 3.With the generator in a level position, remove the oil filler cap. 4.Add enough SAE 10W-30 API service category SJ or later (or equivalent) oil to bring the oil level to the upper limit of the oil filler neck.
31Z398000.book 79 ページ 2013年8月1日 木曜日 午後4時36分 INITIAL USE INSTRUCTIONS FUEL Add fuel to the generator in a well-ventilated area. Never refuel the engine inside a building where gasoline fumes may reach flames or sparks. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, etc. Spilled fuel is not only a fire hazard, it causes environmental damage. Wipe up spills immediately.
31Z398000.book 80 ページ 2013年8月1日 木曜日 午後4時36分 INITIAL USE INSTRUCTIONS 2.Add fuel carefully to avoid spilling fuel. Do not fill the fuel tank above the upper level mark (red) on the fuel filter. UPPER LEVEL MARK (RED) FUEL FILTER TETHER Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel tank. Damage caused by spilled fuel is not covered under warranty.
31Z398000.book 81 ページ 2013年8月1日 木曜日 午後4時36分 INITIAL USE INSTRUCTIONS 3.After refueling, tighten the fuel filler cap until it clicks. Keep the fuel filler cap vent lever OFF for storage or transport, and ON to run the generator. OFF ON FUEL FILLER CAP FUEL FILLER CAP VENT LEVER Move the generator at least 10 feet (3 meters) away from the fueling source and site before starting the engine.
31Z398000.
31Z398000.book 83 ページ 2013年8月1日 木曜日 午後4時36分 INDEX A AC Applications .................................................................... 30 AC OPERATION .................................................................... 28 AIR CLEANER SERVICE .......................................................... 43 Air Index .............................................................................. 63 ARE YOU READY TO GET STARTED? ...................................... 19 B BEFORE OPERATION ...................
31Z398000.book 84 ページ 2013年8月1日 木曜日 午後4時36分 INDEX E Eco-Throttle Switch ............................................................... 14 ECO-THROTTLE SYSTEM ....................................................... 31 Electric Shock Hazards ............................................................. 7 Emission Control System Information ....................................... 61 Emission Control System Warranty .......................................... 73 ENGINE LACKS POWER ...........................
31Z398000.book 85 ページ 2013年8月1日 木曜日 午後4時36分 INDEX K Knowledge ........................................................................... 19 M MAIN AND OUTER FILTERS CLEANING ................................... 45 MAINTENANCE SAFETY ........................................................ 34 MAINTENANCE SCHEDULE .................................................... 35 N NO POWER AT THE AC RECEPTACLES ................................... 58 O Oil Alert Indicator .............................................
31Z398000.book 86 ページ 2013年8月1日 木曜日 午後4時36分 INDEX S SAFE OPERATING PRECAUTIONS ........................................... 21 SAFETY LABEL LOCATIONS ..................................................... 8 Safety Precautions ................................................................ 34 Serial Number Location .......................................................... 59 SERVICING YOUR GENERATOR .............................................. 33 SPARK ARRESTER SERVICE ..................................
31Z398000.
31Z398000.
QUICK REFERENCE INFORMATION The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in closed areas. Breathing carbon monoxide can cause unconsciousness or death. Never run the generator in a closed, or even partly closed area where people may be present. Keep this owner’s manual handy so that you can refer to it at any time.
Owner’s Manual GENERATOR EB2000i 31Z39801 00X31-Z39-8010 AH Hi FM Printed in Thailand C 2013 Honda Motor Co., Ltd.