31Z037210.book 0 ページ 2014年1月27日 月曜日 午後12時2分 The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. California Proposition 65 This product contains or emits chemicals known to the state of California to cause cancer, birth defects or other reproductive harm Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in closed areas.
1Z037210.book 1 ページ 2014年1月27日 月曜日 午後12時2分 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased with your purchase of one of the finest generators on the market. We want to help you get the best results from your new generator and to operate it safely. This manual contains all the information on how to do that; please read it carefully. As you read this manual, you will find information preceded by a symbol.
31Z037210.book 2 ページ 2014年1月27日 月曜日 午後12時2分 A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important. And using this generator safely is an important responsibility. To help you make informed decisions about safety, we have provided operating procedures and other information on labels and in this manual. This information alerts you to potential hazards that could hurt you or others.
31Z037210.book 3 ページ 2014年1月27日 月曜日 午後12時2分 CONTENTS GENERATOR SAFETY .................................................................. 6 IMPORTANT SAFETY INFORMATION ......................................... 6 Operator Responsibility .......................................................... 6 Carbon Monoxide Hazards ...................................................... 6 Electric Shock Hazards........................................................... 7 Fire and Burn Hazards .........................
31Z037210.book 4 ページ 2014年1月27日 月曜日 午後12時2分 CONTENTS OPERATION.............................................................................. 22 SAFE OPERATING PRECAUTIONS ............................................ 22 STARTING THE ENGINE .......................................................... 23 STOPPING THE ENGINE .......................................................... 25 GFCI OPERATION CHECK........................................................ 26 AC OPERATION .................................
31Z037210.book 5 ページ 2014年1月27日 月曜日 午後12時2分 CONTENTS TRANSPORTING ....................................................................... 52 TAKING CARE OF UNEXPECTED PROBLEMS ................................ 53 ENGINE WILL NOT START....................................................... 53 ENGINE LACKS POWER .......................................................... 54 NO POWER AT THE AC RECEPTACLES .................................... 55 TECHNICAL INFORMATION ...........................................
31Z037210.book 6 ページ 2014年1月27日 月曜日 午後12時2分 GENERATOR SAFETY IMPORTANT SAFETY INFORMATION Honda generators are designed for use with electrical equipment that has suitable power requirements. Other uses can result in injury to the operator or damage to the generator and other property. Most injuries or property damage can be prevented if you follow all instructions in this manual and on the generator. The most common hazards are discussed below, along with the best way to protect yourself and others.
31Z037210.book 7 ページ 2014年1月27日 月曜日 午後12時2分 GENERATOR SAFETY Electric Shock Hazards • The generator produces enough electric power to cause a serious shock or electrocution if misused. • Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution. Keep the generator dry.
31Z037210.book 8 ページ 2014年1月27日 月曜日 午後12時2分 GENERATOR SAFETY Refuel With Care Gasoline is extremely flammable, and gasoline vapor can explode. Allow the engine to cool if the generator has been in operation. Refuel only outdoors in a well-ventilated area with the engine off. Do not refuel during operation. Do not overfill the fuel tank. Never smoke near gasoline, and keep other flames and sparks away. Always store gasoline in an approved container.
31Z037210.book 9 ページ 2014年1月27日 月曜日 午後12時2分 GENERATOR SAFETY SAFETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda servicing dealer for a replacement.
31Z037210.book 10 ページ 2014年1月27日 月曜日 午後12時2分 CONTROLS & FEATURES COMPONENT & CONTROL LOCATIONS Use the two illustrations on these pages to locate and identify the most frequently used controls.
31Z037210.
31Z037210.book 12 ページ 2014年1月27日 月曜日 午後12時2分 CONTROL & FEATURES CONTROLS Fuel Valve Lever ON The fuel valve lever is located between the fuel tank and carburetor. OFF The fuel valve lever must be in the ON position for the engine to run. After stopping the engine, turn the fuel valve lever to the OFF position. Engine Switch FUEL VALVE LEVER OFF ON The engine switch controls the ignition system. OFF – Stops the engine. ON – Running position, and for starting with the recoil starter.
31Z037210.book 13 ページ 2014年1月27日 月曜日 午後12時2分 CONTROL & FEATURES Recoil Starter Pulling the starter grip operates the recoil starter to crank the engine for starting. STARTER GRIP • Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter. • Do not let the starter rope rub against the generator body, or the rope will wear out prematurely.
31Z037210.book 14 ページ 2014年1月27日 月曜日 午後12時2分 CONTROL & FEATURES AC Circuit Breaker The AC circuit breaker will automatically switch OFF if there is a short circuit or a significant overload at the receptacles, or if the ground fault circuit interrupter (GFCI) detects a ground fault current. The AC circuit breaker may be used to switch the generator power ON or OFF.
31Z037210.book 15 ページ 2014年1月27日 月曜日 午後12時2分 CONTROL & FEATURES Ground Fault Circuit Interrupter (GFCI) All receptacles on the generator are protected by a Ground Fault Circuit Interrupter (GFCI) for protection against the shock hazard of ground fault current. The GFCI has a TEST button and is connected to the AC circuit breaker.
31Z037210.book 16 ページ 2014年1月27日 月曜日 午後12時2分 CONTROL & FEATURES FEATURES Ground Terminal The ground terminal is connected to the frame of the generator, the metal non-current-carrying parts of the generator, and the ground terminals of each receptacle. Before using the ground terminal, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.
31Z037210.book 17 ページ 2014年1月27日 月曜日 午後12時2分 CONTROL & FEATURES Output Indicator The output indicator (green) will remain ON during normal operating conditions. If there is a short circuit in a connected appliance or if the CycloConverterTM unit overheats, the output indicator (green) blinks and current to the connected appliance(s) will shut off. When this happens, disconnect the appliance(s) and stop the engine to investigate the problem.
31Z037210.book 18 ページ 2014年1月27日 月曜日 午後12時2分 CONTROL & FEATURES Oil Alert Indicator The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert indicator comes on, and the Oil Alert system automatically will stop the engine (the engine switch will remain in the ON position).
31Z037210.book 19 ページ 2014年1月27日 月曜日 午後12時2分 CONTROL & FEATURES Fuel Gauge The fuel gauge is a mechanical device that measures the fuel level in the tank. The red indicator in the window will reference the level in relation to full or empty. To provide increased operating time, start with a full tank before beginning operation. Check the fuel level with the generator on a level surface. Always refuel with the engine OFF and cool.
31Z037210.book 20 ページ 2014年1月27日 月曜日 午後12時2分 BEFORE OPERATION ARE YOU READY TO GET STARTED? Your safety is your responsibility. A little time spent in preparation will significantly reduce your risk of injury. Knowledge Read and understand this manual. Know what the controls do and how to operate them. Familiarize yourself with the generator and its operation before you begin using it. Know how to quickly shut off the generator in case of an emergency.
31Z037210.book 21 ページ 2014年1月27日 月曜日 午後12時2分 BEFORE OPERATION Check the Engine • Before each use, look around and underneath the engine for signs of oil or gasoline leaks. • Check the oil level (see page 37). A low oil level will cause the Oil Alert system to shut down the engine. • Check the air filter (see page 40). A dirty air filter will restrict air flow to the carburetor, reducing engine and generator performance. • Check the fuel level (see page 35).
31Z037210.book 22 ページ 2014年1月27日 月曜日 午後12時2分 OPERATION SAFE OPERATING PRECAUTIONS Before operating the generator for the first time, review chapters GENERATOR SAFETY (see page 6) and BEFORE OPERATION (see page 20). For your safety, do not operate the generator in an enclosed area such as a garage. Your generator’s exhaust contains poisonous carbon monoxide gas that can collect rapidly in an enclosed area and cause illness or death.
31Z037210.book 23 ページ 2014年1月27日 月曜日 午後12時2分 OPERATION STARTING THE ENGINE Refer to SAFE OPERATING PRECAUTIONS on page 22. 1.Make sure that the AC circuit breaker is in the OFF position. The generator may be hard to start if a load is connected. OFF AC CIRCUIT BREAKER 2.Turn the fuel valve lever to the ON position. ON OFF 3.Pull the choke rod to the CLOSED position to start a cold engine. Leave the choke rod in the OPEN position to start a warm engine.
31Z037210.book 24 ページ 2014年1月27日 月曜日 午後12時2分 OPERATION 4.Turn the engine switch to the ON position. ON OFF ENGINE SWITCH 5.Pull the starter grip lightly until resistance is felt, then pull briskly. • Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter. • Do not let the starter rope rub against the generator body, or the rope will wear out prematurely. 6.
31Z037210.book 25 ページ 2014年1月27日 月曜日 午後12時2分 OPERATION STOPPING THE ENGINE To stop the engine in an emergency, simply turn the engine switch to the OFF position. Under normal conditions, use the following procedure. 1.Turn off or disconnect all appliances that are connected to the generator. 2.Switch the AC circuit breaker to the OFF position. OFF AC CIRCUIT BREAKER 3.Turn the engine switch to the OFF position. OFF ON ENGINE SWITCH 4.Turn the fuel valve lever to the OFF position.
31Z037210.book 26 ページ 2014年1月27日 月曜日 午後12時2分 OPERATION GFCI OPERATION CHECK Always check GFCI operation before using the generator. A faulty GFCI can cause electric shock which can seriously injury or kill you. Always perform the GFCI inspection before using the generator. If the GFCI fails the test, the generator must be repaired by an authorized Honda servicing dealer before use. 1.Unplug all tools and appliances from the generator. 2.Start the engine (see page 23). 3.
31Z037210.book 27 ページ 2014年1月27日 月曜日 午後12時2分 OPERATION 5.When you switch the AC circuit breaker to the ON position, LED will turn off. If the GFCI and AC circuit breaker do not function as described, take the generator to an authorized Honda generator dealer for repair. LED ON AC CIRCUIT BREAKER During generator use, if the AC circuit breaker trips, this usually indicates a faulty power tool, appliance, or cord.
31Z037210.book 28 ページ 2014年1月27日 月曜日 午後12時2分 OPERATION AC OPERATION If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is in the appliance or the rated load capacity of the generator has been exceeded. Substantial overloading may damage the generator. Marginal overloading may shorten the service life of the generator. 1.
Z037210.book 29 ページ 2014年1月27日 月曜日 午後12時2分 OPERATION If there is a short circuit in a connected appliance, or if the inverter is overheated, the output indicator (green) will blink and current to the connected appliance(s) will shut off. Stop the engine and investigate the problem. Determine if the cause is a short circuit in a connected appliance, or an overheated inverter. Correct the problem and restart the generator.
31Z037210.book 30 ページ 2014年1月27日 月曜日 午後12時2分 OPERATION AC Applications Before connecting an appliance or power cord to the generator: • Make sure that it is in good working order. A faulty appliance or power cord can create a potential for electrical shock. • If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is the appliance or the rated load capacity of the generator has been exceeded.
31Z037210.book 31 ページ 2014年1月27日 月曜日 午後12時2分 OPERATION STANDBY POWER Connections to a Building’s Electrical System Do not connect an EB3000c generator to a home or building’s electrical system. The Honda EB3000c generator is designed for construction job site use and cannot be connected to a building’s electrical system. This generator has the neutral bonded to ground to comply with OSHA job site temporary power regulation.
31Z037210.book 32 ページ 2014年1月27日 月曜日 午後12時2分 SERVICING YOUR GENERATOR THE IMPORTANCE OF MAINTENANCE Good maintenance is essential for safe, economical, and trouble free operation. It will also help reduce air pollution. To help you properly care for your generator, the following pages include a maintenance schedule, routine inspection procedures, and simple maintenance procedures using basic hand tools.
31Z037210.book 33 ページ 2014年1月27日 月曜日 午後12時2分 SERVICING YOUR GENERATOR MAINTENANCE SAFETY Some of the most important safety precautions follow. However, we cannot warn you of every conceivable hazard that can arise in performing maintenance. Only you can decide whether or not you should perform a given task. Failure to properly follow maintenance instructions and precautions can cause you to be seriously hurt or killed. Always follow the procedures and precautions in the owner’s manual.
31Z037210.book 34 ページ 2014年1月27日 月曜日 午後12時2分 SERVICING YOUR GENERATOR MAINTENANCE SCHEDULE REGULAR SERVICE PERIOD (3) ITEM Perform at every indicated month or operating hour interval, whichever comes first.
31Z037210.book 35 ページ 2014年1月27日 月曜日 午後12時2分 SERVICING YOUR GENERATOR REFUELING With the engine stopped, check the fuel level gauge. Refill the fuel tank if the fuel level is low. Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. • Stop the engine and keep heat, sparks, and flame away. • Handle fuel only outdoors. • Wipe up spills immediately. Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel tank.
31Z037210.book 36 ページ 2014年1月27日 月曜日 午後12時2分 SERVICING YOUR GENERATOR FUEL TANK CAP UPPER LEVEL MARK (RED) TETHER FUEL GAUGE FULL EMPTY After refueling, reinstall the fuel tank cap securely. FUEL RECOMMENDATIONS This engine is certified to operate on regular unleaded gasoline with a pump octane rating of 86 or higher. Never use stale or contaminated gasoline or an oil/gasoline mixture. Avoid getting dirt or water in the fuel tank.
31Z037210.book 37 ページ 2014年1月27日 月曜日 午後12時2分 SERVICING YOUR GENERATOR ENGINE OIL LEVEL CHECK Check the engine oil level with the generator on a level surface and the engine stopped. 1.Remove the oil filler cap. 2.Check the oil level. If it is below the upper limit, fill with the recommended oil to the upper limit of the oil filler neck (see page 39). 3.Reinstall the oil filler cap securely.
31Z037210.book 38 ページ 2014年1月27日 月曜日 午後12時2分 SERVICING YOUR GENERATOR ENGINE OIL CHANGE Drain the oil while the engine is warm to assure rapid and complete draining. 1.Place a suitable container below the engine to catch the used oil, and then remove the oil filler cap, drain plug, and sealing washer. 2.Allow the used oil to drain completely, and then reinstall the drain plug and a new sealing washer. Tighten the plug securely. Improper disposal of engine oil can be harmful to the environment.
31Z037210.book 39 ページ 2014年1月27日 月曜日 午後12時2分 SERVICING YOUR GENERATOR ENGINE OIL RECOMMENDATIONS Oil is a major factor affecting performance and service life. Use 4-stroke automotive detergent oil. SAE 10W–30 is recommended for general use. Other viscosities shown in the chart may be used when the average temperature in your area is within the recommended range. AMBIENT TEMPERATURE The SAE oil viscosity and service classification are in the API label on the oil container.
31Z037210.book 40 ページ 2014年1月27日 月曜日 午後12時2分 SERVICING YOUR GENERATOR AIR CLEANER SERVICE 1.Unsnap the air cleaner cover clips, and remove the air cleaner cover. AIR CLEANER COVER CLIPS 2.Check the foam air filter and paper air filter to be sure they are clean and in good condition. If the foam air filter is dirty, clean it as described on page 41. If the paper air filter is dirty, replace it with new one. Do not clean the paper air filter. FOAM AIR FILTER 3.Reinstall the air cleaner cover.
31Z037210.book 41 ページ 2014年1月27日 月曜日 午後12時2分 SERVICING YOUR GENERATOR FOAM AIR FILTER CLEANING A dirty foam air filter will restrict air flow to the carburetor, reducing engine performance. If you operate the generator in very dusty areas, clean the foam air filter more frequently than specified in the Maintenance Schedule. 1.Wash the foam air filter in a solution of household detergent and warm water, then rinse thoroughly, or wash in non-flammable or high flash point solvent.
31Z037210.book 42 ページ 2014年1月27日 月曜日 午後12時2分 SERVICING YOUR GENERATOR SEDIMENT CUP CLEANING The sediment cup prevents water that may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned. 1.Turn the engine switch to the OFF position. 2.Turn the fuel valve lever to the OFF position. 3.Unscrew the sediment cup. Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel.
31Z037210.book 43 ページ 2014年1月27日 月曜日 午後12時2分 SERVICING YOUR GENERATOR 4.Clean the sediment cup in non-flammable or high flash point solvent. 5.Install the sediment cup and a new O-ring. 6.Turn the fuel valve to the ON position and check for leaks.
31Z037210.book 44 ページ 2014年1月27日 月曜日 午後12時2分 SERVICING YOUR GENERATOR SPARK PLUG SERVICE In order to service the spark plug, you will need a spark plug wrench (commercially available). Recommended spark plugs: BPR6ES (NGK) W20EPR-U (DENSO) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. An incorrect spark plug can cause engine damage. If the engine is hot, allow it to cool before servicing the spark plug. 1.Remove the spark plug cap. 2.
31Z037210.book 45 ページ 2014年1月27日 月曜日 午後12時2分 SERVICING YOUR GENERATOR 4.Visually inspect the spark plug. Replace it if the electrodes are worn or if the insulator is cracked, chipped, or fouled. 5.Measure the spark plug electrode gap with a wire-type feeler gauge. Correct the gap, if necessary, by carefully bending the side electrode. The gap should be: 0.028–0.031 in (0.7–0.8 mm) SIDE ELECTRODE 0.028–0.031 in (0.7–0.8 mm) SEALING WASHER INSULATOR 6.
31Z037210.book 46 ページ 2014年1月27日 月曜日 午後12時2分 SERVICING YOUR GENERATOR SPARK ARRESTER SERVICE If the generator has been running, the muffler will be very hot. Allow it to cool before proceeding. The spark arrester must be serviced every 100 hours to maintain its efficiency. 1.Remove the 4 mm self-tapping screw, and remove the spark arrester from the muffler. SPARK ARRESTER 4 mm SELF-TAPPING SCREW 2.Use a brush to remove carbon deposits from the spark arrester screen. 3.
31Z037210.book 47 ページ 2014年1月27日 月曜日 午後12時2分 STORAGE STORAGE PREPARATION Proper storage preparation is essential for keeping your generator trouble-free and looking good. The following steps will help to keep rust and corrosion from impairing your generator’s function and appearance, and will make the engine easier to start when you use the generator again. Cleaning Wipe the generator with a moist cloth.
31Z037210.book 48 ページ 2014年1月27日 月曜日 午後12時2分 STORAGE Service according to the table below: RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required Fill with fresh gasoline and add gasoline 1 to 2 months stabilizer*. Fill with fresh gasoline and add gasoline 2 months to 1 year stabilizer*. Drain the carburetor float bowl (see page 49). Drain the fuel sediment cup (see page 42). Fill with fresh gasoline and add gasoline stabilizer*.
31Z037210.book 49 ページ 2014年1月27日 月曜日 午後12時2分 STORAGE Draining the Fuel Tank and Carburetor Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. • Stop the engine and keep heat, sparks, and flame away. • Handle fuel only outdoors. • Wipe up spills immediately. 1.Place a suitable gasoline container below the carburetor. 2.
31Z037210.book 50 ページ 2014年1月27日 月曜日 午後12時2分 STORAGE Engine Oil 1.Change the engine oil (see page 38). 2.Remove the spark plug (see page 44). 3.Pour a teaspoon (5 cc) of clean engine oil into the cylinder. 4.Pull the starter rope several times to distribute the oil in the cylinder. 5.Reinstall the spark plug (see page 45). 6.Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up on its compression stroke and both the intake and exhaust valves are closed.
31Z037210.book 51 ページ 2014年1月27日 月曜日 午後12時2分 STORAGE STORAGE PRECAUTIONS If your generator will be stored with gasoline in the fuel tank and carburetor, it is important to reduce the hazard of gasoline vapor ignition. Select a well ventilated storage area away from any appliance that operates with a flame, such as a furnace, water heater, or clothes dryer. Also avoid any area with a spark-producing electric motor, or where power tools are operated.
31Z037210.book 52 ページ 2014年1月27日 月曜日 午後12時2分 TRANSPORTING Do not lay the generator on its side when moving, storing, or operating it. Oil or fuel may leak and damage the engine or your property. If the generator has been used, allow it cool for at least 15 minutes before loading the generator on the transport vehicle. A hot engine and exhaust system can burn you and can ignite some material.
31Z037210.book 53 ページ 2014年1月27日 月曜日 午後12時2分 TAKING CARE OF UNEXPECTED PROBLEMS ENGINE WILL NOT START Possible Cause Fuel valve lever OFF. Engine switch OFF. Correction Turn lever ON (see page 23). Turn engine switch to ON (see page 24). Out of fuel. Refuel (see page 35). Bad fuel; generator stored without Drain fuel tank and carburetor (see page 49). treating or draining gasoline, or refueled with bad gasoline. Refuel with fresh gasoline (see page 35). Add oil (see page 37).
31Z037210.book 54 ページ 2014年1月27日 月曜日 午後12時2分 TAKING CARE OF UNEXPECTED PROBLEMS ENGINE LACKS POWER Possible Cause Air filter restricted. Correction Clean or replace air filter (see pages 40, 41). Bad fuel; generator stored without Drain fuel tank and carburetor (see page 49). treating or draining gasoline, or refueled with bad gasoline. Refuel with fresh gasoline (see page 35).
31Z037210.book 55 ページ 2014年1月27日 月曜日 午後12時2分 TAKING CARE OF UNEXPECTED PROBLEMS NO POWER AT THE AC RECEPTACLES Possible Cause Output indicator blinks. AC circuit breaker left in the OFF position after starting. GFCI activated. AC circuit protector tripped. Faulty power tool or appliance. Faulty generator. Correction Check AC load. Stop and restart the engine. Check the cooling air inlet. Stop and restart the engine. Check AC load and reset AC circuit breaker (see page 28).
31Z037210.book 56 ページ 2014年1月27日 月曜日 午後12時2分 TECHNICAL INFORMATION Serial Number Location FRAME SERIAL NUMBER Record the frame serial number in the space below. You will need this serial number when ordering parts, and when making technical or warranty inquiries.
31Z037210.book 57 ページ 2014年1月27日 月曜日 午後12時2分 TECHNICAL INFORMATION Carburetor Modification for High Altitude Operation At high altitude, the standard carburetor air-fuel mixture will be too rich. Performance will decrease, and fuel consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting. Operation at an altitude that differs from that at which this engine was certified, for extended periods of time, may increase emissions.
31Z037210.book 58 ページ 2014年1月27日 月曜日 午後12時2分 TECHNICAL INFORMATION Emission Control System Information Source of Emissions The combustion process produces carbon monoxide, oxides of nitrogen, and hydrocarbons. Control of hydrocarbons and oxides of nitrogen are very important because, under certain conditions, they react to form photochemical smog when subjected to sunlight. Carbon monoxide does not react in the same way, but it is toxic.
31Z037210.book 59 ページ 2014年1月27日 月曜日 午後12時2分 TECHNICAL INFORMATION Problems That May Affect Emissions If you are aware of any of the following symptoms, have your engine inspected and repaired by your authorized Honda servicing dealer. • Hard starting or stalling after starting. • Rough idle. • Misfiring or backfiring under load. • Afterburning (backfiring). • Black exhaust smoke or high fuel consumption.
31Z037210.book 60 ページ 2014年1月27日 月曜日 午後12時2分 TECHNICAL INFORMATION Air Index (Models sold in California) An Air Index Information label is applied to engines certified to an emission durability time period in accordance with the requirements of the California Air Resources Board. The bar graph is intended to provide you, our customer, the ability to compare the emissions performance of available engines. The lower the Air Index, the less pollution.
31Z037210.book 61 ページ 2014年1月27日 月曜日 午後12時2分 TECHNICAL INFORMATION Specifications Dimensions Model (Type) Description code Length Width Height Dry mass [weight] EB3000c EZGP 17.5 in (445 mm) 15.8 in (402 mm) 18.9 in (480 mm) 71.0 lbs (32.2 kg) Engine Model Engine type Displacement Bore×Stroke Compression ratio Engine speed Cooling system Ignition system Oil capacity Fuel tank capacity Spark plug GX200T 4-stroke, overhead valve, single cylinder 12.0 cu-in (196 cm3) 2.68×2.13 in (68.0×54.0 mm) 8.
31Z037210.
31Z037210.book 63 ページ 2014年1月27日 月曜日 午後12時2分 CONSUMER INFORMATION Dealer Locator Information To find an authorized Honda Servicing Dealer anywhere in the United States: Visit our website: http://powerequipment.honda.com/dealer-locator Honda Publications Shop Manual This manual covers complete maintenance and overhaul procedures. It is intended to be used by a skilled technician. Available through your Honda dealer or visit http://powerequipment.honda.
31Z037210.book 64 ページ 2014年1月27日 月曜日 午後12時2分 CONSUMER INFORMATION Customer Service Information Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership’s management. The Service Manager or General Manager can help. Almost all problems are solved in this way.
31Z037210.book 65 ページ 2014年1月27日 月曜日 午後12時2分 INITIAL USE INSTRUCTIONS ENGINE OIL The generator is shipped WITHOUT OIL in the engine. 1.Place the generator on a level surface. 2.Remove the oil filler cap. 3.Add enough oil to bring the oil level to the upper limit of the oil filler neck. SAE 10W-30 API service category SJ or later (or equivalent) is recommended for general use; for additional recommendations (see page 37). Maximum oil capacity: 18 oz (0.55 L) Do not overfill the engine with oil.
31Z037210.book 66 ページ 2014年1月27日 月曜日 午後12時2分 INITIAL USE INSTRUCTIONS FUEL Add fuel to the generator in a well-ventilated area. Never refuel the engine inside a building where gasoline fumes may reach flames or sparks. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, etc. Spilled fuel is not only a fire hazard, it causes environmental damage. Wipe up spills immediately.
31Z037210.book 67 ページ 2014年1月27日 月曜日 午後12時2分 INITIAL USE INSTRUCTIONS Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel tank. Damage caused by spilled fuel is not covered under warranty. Move the generator at least 10 feet (3 meters) away from the fueling source and site before starting the engine.
31Z037210.book 68 ページ 2014年1月27日 月曜日 午後12時2分 INDEX A AC Applications .................................................................... AC Circuit Breaker................................................................. AC Circuit Protector .............................................................. AC OPERATION .................................................................... AIR CLEANER SERVICE.......................................................... Air Index .................................
31Z037210.book 69 ページ 2014年1月27日 月曜日 午後12時2分 INDEX F FEATURES ........................................................................... 16 Fire and Burn Hazards .............................................................. 7 FOAM AIR FILTER CLEANING ................................................. 41 Fuel ............................................................................... 47, 66 Fuel Gauge ........................................................................... 19 FUEL RECOMMENDATIONS.
31Z037210.book 70 ページ 2014年1月27日 月曜日 午後12時2分 INDEX M MAINTENANCE SAFETY ........................................................ 33 MAINTENANCE SCHEDULE .................................................... 34 N NO POWER AT THE AC RECEPTACLES ................................... 55 O Oil Alert Indicator .................................................................. 18 OPERATION.......................................................................... 22 Operator Responsibility .........................
31Z037210.book 71 ページ 2014年1月27日 月曜日 午後12時2分 INDEX S SAFE OPERATING PRECAUTIONS ........................................... 22 SAFETY LABEL LOCATIONS..................................................... 9 Safety Precautions ................................................................ 33 SEDIMENT CUP CLEANING .................................................... 42 Serial Number Location .......................................................... 56 SERVICING YOUR GENERATOR .............................
31Z037210.
31Z037210.book 73 ページ 2014年1月27日 月曜日 午後12時2分 QUICK REFERENCE INFORMATION Fuel Engine Oil Spark Plug Maintenance Type Unleaded gasoline with an ethanol content of no more than 10% and a pump octane rating of 86 or higher Type SAE 10W-30, API SJ or later (or equivalent), for general use (see page 39) Type BPR6ES (NGK) W20EPR-U (DENSO) Electrode Gap 0.028–0.031 in (0.7–0.8 mm) Before each use Check engine oil level. Check air filter. Check GFCI operation. First 20 hours Change engine oil.