TAKING CARE OF UNEXPECTED PROBLEMS
NO POWER AT THE AC RECEPTACLES
Possible Cause Correction
Output indicator blinks. Check AC load. Stop and restart
the eng
ine.
Check the cooling air inlet. Stop
and re
start the engine.
AC circuit breaker left in the OFF
position after starting
.
Check AC load and reset AC
circuit breaker (see page 28).
GFCI activated. Test GFCI (see page 26) and reset
AC circuit breaker.
Replace faulty power tool or
appliance.
A
C circuit protector tripped. Check AC load and reset circuit
protect
or (see page 13).
Faulty power tool or appliance. Replace or repair power tool or
appliance.
St
op and restart the engine.
Faulty generator. Take the generator to an
authorized Ho
nda servicing dealer,
or refer to the shop manual.