Operation Manual

14
OIL ALERT SYSTEM
Auto-throttle System
AUTO:
OFF:
AUTO
OFF
OIL FILLER HOLE
AUTO-THROTTLE
SWITCH
UPPER
LEVEL
OIL FILLER CAP
The auto-throttle system automatically reduces engine speed when all
loads are turned off or disconnected. When appliances are turned on
or reconnected, the engine returns to the rated speed.
Recommended to minimize fuel consumption and further
reduce noise levels when no load is applied to the generator.
The auto-throttle system does not operate.
Recommended to minimize warm-up time when the
generator is started.
The Oil Alert
system is designed to prevent engine damage caused
by an insufficient amount of oil in the crankcase. Before the oil level in
the crankcase can fall below a safe limit, the Oil Alert
system will
automatically stop the engine (the engine switch will remain in the ON
position).
If the engine stops and will not restart, check the engine oil level (see
page ) before troubleshooting in other areas.
25
01/07/23 12:08:33 31ZB4800_015