Operation Manual

22
Disconnecting the battery cables:
DC CIRCUIT
PROTECTOR
NEGATIVE TERMINAL
(BLACK)
POSITIVE TERMINAL
(RED)
Reconnect the vehicle grounded battery cable.
Connect the vehicle ground battery cable to the battery negative ( )
terminal.
Disconnect the positive ( ) battery cable from the generator
positive ( ) terminal.
Disconnect the other end of the positive ( ) battery cable from the
battery positive ( ) terminal.
Disconnect the negative ( ) battery cable from the generator
negative ( ) terminal.
Disconnect the other end of the negative ( ) battery cable from the
battery negative ( ) terminal.
Stop the engine.
An overloaded DC circuit, excessive current draw by the battery, or a
wiring problem will trip the DC circuit protector (PUSH button extends
out). If this happens, wait a few minutes before pushing in the circuit
protector to resume operation. If the circuit protector continues to go
OFF, discontinue charging and see your authorized Honda generator
dealer.
1.
2.
3.
4.
5.
6.
7.