EU1000i_OMcover_31Z40603_F Owner’s Manual GENERATOR EU1000i Click to Save As See page 84 for Initial Use Instructions 31Z40603 00X31-Z40-6030 PANTONE 186C K 背幅3mm AH 英 FM Hi Printed in Thailand C 2017 Honda Motor Co., Ltd.
EU1000i_OMcover_31Z40603_F QUICK REFERENCE INFORMATION The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. California Proposition 65 This product contains or emits chemicals known to the state of California to cause cancer, birth defects or other reproductive harm Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in closed areas.
1Z406030.book 1 ページ 2017年3月14日 火曜日 午後2時49分 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased with your purchase of one of the finest generators on the market. We want to help you get the best results from your new generator and to operate it safely. This manual contains the information on how to do that; please read it carefully. As you read this manual, you will find information preceded by a symbol.
31Z406030.book 2 ページ 2017年3月14日 火曜日 午後2時49分 A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important. And using this generator safely is an important responsibility. To help you make informed decisions about safety, we have provided operating procedures and other information on labels and in this manual. This information alerts you to potential hazards that could hurt you or others.
31Z406030.book 3 ページ 2017年3月14日 火曜日 午後2時49分 CONTENTS GENERATOR SAFETY ..............................................................................6 IMPORTANT SAFETY INFORMATION ................................................6 Operator Responsibility.................................................................... 6 Carbon Monoxide Hazards............................................................... 6 Electric Shock Hazards .....................................................................
31Z406030.book 4 ページ 2017年3月14日 火曜日 午後2時49分 CONTENTS OPERATION ............................................................................................21 SAFE OPERATING PRECAUTIONS ....................................................21 STARTING THE ENGINE ....................................................................22 STOPPING THE ENGINE ....................................................................25 AC OPERATION ........................................................................
31Z406030.book 5 ページ 2017年3月14日 火曜日 午後2時49分 CONTENTS TRANSPORTING .....................................................................................61 TAKING CARE OF UNEXPECTED PROBLEMS .....................................62 ENGINE WILL NOT START .................................................................62 ENGINE LACKS POWER .....................................................................63 NO POWER AT THE AC RECEPTACLES ............................................
31Z406030.book 6 ページ 2017年3月14日 火曜日 午後2時49分 GENERATOR SAFETY IMPORTANT SAFETY INFORMATION Honda generators are designed for use with electrical equipment that has suitable power requirements. Other uses can result in injury to the operator or damage to the generator and other property. Most injuries or property damage can be prevented if you follow all the instructions in this manual and on the generator.
31Z406030.book 7 ページ 2017年3月14日 火曜日 午後2時49分 GENERATOR SAFETY Electric Shock Hazards • The generator produces enough electric power to cause a serious shock or electrocution if misused. • Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution. Keep the generator dry.
31Z406030.book 8 ページ 2017年3月14日 火曜日 午後2時49分 GENERATOR SAFETY Refuel With Care Gasoline is extremely flammable, and gasoline vapor can explode. Do not refuel during operation. Allow the engine to cool if it has been in operation. Refuel only outdoors in a well-ventilated area and on a level surface. Never smoke near gasoline, and keep other flames and sparks away. Do not overfill the fuel tank. Make sure that any spilled fuel has been wiped up and cleaned before starting the engine.
31Z406030.book 9 ページ 2017年3月14日 火曜日 午後2時49分 GENERATOR SAFETY SAFETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda servicing dealer for a replacement.
31Z406030.
31Z406030.book 11 ページ 2017年3月14日 火曜日 午後2時49分 CONTROLS & FEATURES COMPONENT & CONTROL LOCATIONS Use the illustrations on these pages to locate and identify the most frequently used controls.
31Z406030.
31Z406030.book 13 ページ 2017年3月14日 火曜日 午後2時49分 CONTROLS & FEATURES CONTROLS Engine Switch ENGINE SWITCH The engine switch controls the ignition system and the fuel valve. ON OFF – Stops the engine and closes the fuel valve. ON – Running position; opens the fuel valve and allows the engine to be started. Starter Grip OFF Pulling the starter grip operates the recoil starter to start the engine. STARTER GRIP Do not allow the starter grip to snap back against the generator.
31Z406030.book 14 ページ 2017年3月14日 火曜日 午後2時49分 CONTROLS & FEATURES Fuel Filler Cap Vent Lever The fuel filler cap is provided with a vent lever to seal the fuel tank. The fuel filler cap vent lever must be in the ON position for the engine to run. When the engine is not in use, leave the fuel filler cap vent lever in the OFF position to reduce the possibility of fuel leakage. Allow the engine to cool before turning the fuel filler cap vent lever to the OFF position.
31Z406030.book 15 ページ 2017年3月14日 火曜日 午後2時49分 CONTROLS & FEATURES Eco Throttle® Switch The Eco Throttle® system automatically reduces engine speed when loads are turned off or disconnected. When appliances are turned on or reconnected, the engine returns to the proper speed to power the electrical load. If high electrical loads are connected simultaneously, turn the Eco Throttle switch to the OFF position to reduce voltage changes.
31Z406030.book 16 ページ 2017年3月14日 火曜日 午後2時49分 CONTROLS & FEATURES DC Receptacle The DC receptacle should ONLY be used for charging 12 volt automotive type batteries. The DC charging output is not regulated. This means that the charging output does not decrease as the battery reaches full charge. Check the battery voltage frequently while charging to prevent overcharging the battery.
31Z406030.book 17 ページ 2017年3月14日 火曜日 午後2時49分 CONTROLS & FEATURES FEATURES Output Indicator The output indicator (green) is illuminated when the generator is operating normally. It indicates that the generator is producing electrical power at the receptacles. In addition, the output indicator has a simplified hour meter function.
31Z406030.book 18 ページ 2017年3月14日 火曜日 午後2時49分 CONTROLS & FEATURES Oil Alert® Indicator The Oil Alert® system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert indicator (red) comes ON and the Oil Alert system automatically will stop the engine (the engine switch will remain in the ON position).
31Z406030.book 19 ページ 2017年3月14日 火曜日 午後2時49分 BEFORE OPERATION ARE YOU READY TO GET STARTED? Your safety is your responsibility. A little time spent in preparation will significantly reduce your risk of injury. Knowledge Read and understand this manual. Know what the controls do and how to operate them. Familiarize yourself with the generator and its operation before you begin using it. Know how to quickly shut off the generator in case of an emergency.
31Z406030.book 20 ページ 2017年3月14日 火曜日 午後2時49分 BEFORE OPERATION To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from building walls and other equipment during operation. Do not place flammable objects close to the engine. Before beginning your pre-operation checks, be sure the generator is on a level and firm surface and the engine switch is in the OFF position. Check the Engine • Before each use, look around and underneath the engine for signs of oil or gasoline leaks.
31Z406030.book 21 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION SAFE OPERATING PRECAUTIONS Before operating the generator for the first time, review chapters GENERATOR SAFETY (see page 6) and BEFORE OPERATION (see page 19). For your safety, do not operate the generator in an enclosed area such as a garage. Your generator’s exhaust contains poisonous carbon monoxide gas that can collect rapidly in an enclosed area and cause illness or death.
31Z406030.book 22 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION STARTING THE ENGINE To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from building walls and other equipment during operation. Do not place flammable objects close to the engine. • Operating this generator less than 3 feet (1 meter) from a building or other obstruction can cause overheating and damage the generator. • For proper cooling, allow at least 3 feet (1 meter) of empty space above and around the generator.
31Z406030.book 23 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION 3. Make sure the Eco Throttle switch is in the OFF position, or more time will be required for warm-up. ECO THROTTLE SWITCH OFF 4. To start a cold engine, move the choke lever to the CLOSED position. To restart a warm engine, leave the choke lever in the OPEN position. CHOKE LEVER OPEN CLOSED 5. Turn the engine switch to the ON position.
31Z406030.book 24 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION 6. Pull the starter grip lightly until you feel resistance; then pull briskly in the direction of the arrow as shown. STARTER GRIP Direction to pull Do not allow the starter grip to snap back against the generator. Return it gently to prevent damage to the starter. 7. If the choke lever was moved to the CLOSED position to start the engine, gradually move it to the OPEN position as the engine warms up. CHOKE LEVER OPEN CLOSED 8.
31Z406030.book 25 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION STOPPING THE ENGINE To stop the engine in an emergency, simply turn the engine switch to the OFF position. Under normal conditions, use the following procedure. 1. Turn off or disconnect all appliances that are connected to the generator. 2. Turn the engine switch to the OFF position. ON ENGINE SWITCH OFF 3. Allow the engine to cool, and then turn the fuel filler cap vent lever to the OFF position.
31Z406030.book 26 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION 4. If two generators were connected for parallel operation, disconnect the parallel operation cable after stopping the engines if you do not wish to resume parallel operation.
31Z406030.book 27 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION AC OPERATION Before connecting an appliance to the generator, make sure that it is in good working order and that its electrical rating does not exceed that of the generator. Most motorized appliances require more than their electrical rating for startup. When an electric motor is started, the overload indicator (red) may come ON. This is normal if the overload indicator (red) goes OFF within 4 seconds.
31Z406030.book 28 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION 2. Plug the appliance into the receptacle. 3. Turn on the appliance. If the generator is overloaded (see page 29), or if there is a short circuit in a connected appliance, the overload indicator (red) will go ON. The overload indicator (red) will stay ON, and after about four seconds, current to the connected appliance(s) will shut off, and the output indicator (green) will go OFF. Stop the engine and investigate the problem.
Z406030.book 29 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION AC Applications Before connecting an appliance or power cord to the generator: • Make sure that it is in good working order. A faulty appliance or power cord can create a potential for electrical shock. • If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is the appliance or the rated load capacity of the generator has been exceeded.
31Z406030.book 30 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION AC PARALLEL OPERATION Before connecting an appliance to either generator, make sure that the appliance is in good working order and that its electrical rating does not exceed that of the receptacle. Most motorized appliances require more than their electrical rating for startup. When an electric motor is started, the overload indicator (red) may come ON. This is normal if the overload indicator (red) goes OFF within 4 seconds.
31Z406030.book 31 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION 3. Plug the appliance following the instruction provided with the parallel operation cable. 4. Turn on the appliance. If the generators are overloaded (see page 33), or if there is a short circuit in a connected appliance, the overload indicator (red) will go ON. The overload indicator (red) will stay ON, and after about four seconds, current to the connected appliance(s) will shut off, and the output indicator (green) will go OFF.
31Z406030.book 32 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION AC Parallel Operation Applications Follow the instructions included with the parallel operation cable. Before connecting an appliance or power cord to the generator: • Make sure that it is in good working order. A faulty appliance or power cord can create a potential for electrical shock. • If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately.
31Z406030.book 33 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION Most appliance motors require more than their rated wattage for startup. Make sure the electrical rating of the tool or appliance does not exceed the maximum power rating of the generator. Maximum power in parallel operation is: 2.0 kVA For continuous operation, do not exceed the rated power. Rated power in parallel operation is: 1.8 kVA In either case, the total power requirements (VA) of all appliances connected must be considered.
31Z406030.book 34 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION DC OPERATION The DC receptacle should ONLY be used for charging 12 volt automotive type batteries. The DC charging output is not regulated. This means that the charging output is constant; it does not decrease as the battery reaches full charge. Check the battery voltage frequently while charging to prevent overcharging the battery. When using the DC output, turn the Eco Throttle switch to the OFF position.
31Z406030.book 35 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION 3. Connect the red lead of the battery charging cable to the positive (+) battery terminal and the black lead to the negative (–) battery terminal. 4. Start the generator (see page 22). Do not start the vehicle while the battery charging cable is connected and the generator is running. The vehicle or the generator may be damaged.
31Z406030.book 36 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION Disconnecting the battery charging cable (optional equipment): 1. Stop the engine. 2. Disconnect the black lead of the battery charging cable from the negative (–) battery terminal. 3. Disconnect the red lead of the battery charging cable from the positive (+) battery terminal. 4. Disconnect the battery charging cable from the DC receptacle of the generator. 5. Connect the vehicle battery ground cable to the negative (–) battery terminal.
31Z406030.book 37 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION ECO THROTTLE® SYSTEM With the switch in the ON position, engine speed is automatically lowered when loads are reduced, turned off, or disconnected. When appliances are turned on or reconnected, the engine returns to the proper speed to power the electrical load. In the OFF position, the Eco Throttle® system does not operate.
31Z406030.book 38 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION STANDBY POWER Connections to a Building’s Electrical System Connections for standby power to a building’s electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes. Improper connections to a building’s electrical system can allow current from the generator to backfeed into the utility lines.
31Z406030.book 39 ページ 2017年3月14日 火曜日 午後2時49分 OPERATION Special Requirements Do not lay the generator on its side when moving, storing, or operating it. Oil may leak and damage the engine or your property. There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.
31Z406030.book 40 ページ 2017年3月14日 火曜日 午後2時49分 SERVICING YOUR GENERATOR THE IMPORTANCE OF MAINTENANCE Good maintenance is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. To help you properly care for your generator, the following pages include a maintenance schedule, routine inspection procedures, and simple maintenance procedures using basic hand tools.
31Z406030.book 41 ページ 2017年3月14日 火曜日 午後2時49分 SERVICING YOUR GENERATOR MAINTENANCE SAFETY Some of the most important safety precautions follow. However, we cannot warn you of every conceivable hazard that can arise in performing maintenance. Only you can decide whether or not you should perform a given task. Improper maintenance can cause an unsafe condition. Failure to properly follow maintenance instructions and precautions can cause you to be seriously hurt or killed.
31Z406030.book 42 ページ 2017年3月14日 火曜日 午後2時49分 SERVICING YOUR GENERATOR MAINTENANCE SCHEDULE REGULAR SERVICE PERIOD (3) Perform at every indicated month or operating hour interval, whichever comes first. ITEM Engine oil Check level Change Air cleaner Check Clean Spark plug Check-adjust Replace Spark arrester Clean Valve clearance Check-adjust Combustion chamber Clean Fuel tank and filter Clean Fuel tube Check Each use Every First Every Every 3 month 6 2 years months months or or or 10 hrs. or 300 hrs.
31Z406030.book 43 ページ 2017年3月14日 火曜日 午後2時49分 SERVICING YOUR GENERATOR REFUELING With the engine stopped, remove the fuel filler cap and check the fuel level. Refill the fuel tank if the fuel level is low. Gasoline is highly flammable and explosive, and you can be burned or seriously injured when handling fuel. • Stop the engine and let it cool before handling fuel. • Keep heat, sparks, and flame away. • Handle fuel only outdoors. • Wipe up spills immediately. Fuel can damage paint and plastic.
31Z406030.book 44 ページ 2017年3月14日 火曜日 午後2時49分 SERVICING YOUR GENERATOR FUEL FILLER CAP UPPER LEVEL MARK (RED) FUEL FILTER After refueling, reinstall the fuel filler cap securely. FUEL RECOMMENDATIONS This engine is certified to operate on regular unleaded gasoline with a pump octane rating of 86 or higher. Never use gasoline that is stale, contaminated, or mixed with oil. Avoid getting dirt or water in the fuel tank.
31Z406030.book 45 ページ 2017年3月14日 火曜日 午後2時49分 SERVICING YOUR GENERATOR ENGINE OIL LEVEL CHECK Check the engine oil level with the generator on a level surface and the engine stopped. 1. Loosen the maintenance cover screw and remove the maintenance cover.
31Z406030.book 46 ページ 2017年3月14日 火曜日 午後2時49分 SERVICING YOUR GENERATOR 2. Remove the oil filler cap. 3. Check the oil level. If it is below the upper limit, fill with the recommended oil (see page 48) to the upper limit of the oil filler neck. 4. Reinstall the oil filler cap securely. 5. Reinstall the maintenance cover and tighten the maintenance cover screw securely.
31Z406030.book 47 ページ 2017年3月14日 火曜日 午後2時49分 SERVICING YOUR GENERATOR ENGINE OIL CHANGE Drain the oil while the engine is warm to assure rapid and complete draining. 1. Turn the engine switch and fuel filler cap vent lever to the OFF position (see page 25) to reduce the possibility of fuel leakage. 2. Loosen the maintenance cover screw and remove the maintenance cover (see page 45). 3. Place a suitable container next to the engine to catch the used oil. 4.
31Z406030.book 48 ページ 2017年3月14日 火曜日 午後2時49分 SERVICING YOUR GENERATOR ENGINE OIL RECOMMENDATIONS Oil is a major factor affecting performance and service life. Use 4-stroke automotive detergent oil. SAE 10W–30 is recommended for general use. Other viscosities shown in the chart may be used when the average temperature in your area is within the recommended range. AMBIENT TEMPERATURE The SAE oil viscosity and service category are in the API label on the oil container.
31Z406030.book 49 ページ 2017年3月14日 火曜日 午後2時49分 SERVICING YOUR GENERATOR AIR CLEANER SERVICE MAINTENANCE COVER SCREW 1. Loosen the maintenance cover screw and remove the maintenance cover. 2. Press the latch tab on the top of the air cleaner case, and remove the air cleaner cover. 3. Check the foam air filter to be sure it is clean and in good condition. If the foam air filter is dirty, clean it as described on page 50. Replace the foam air filter if it is damaged. 4. Reinstall the air filter.
31Z406030.book 50 ページ 2017年3月14日 火曜日 午後2時49分 SERVICING YOUR GENERATOR FOAM AIR FILTER CLEANING A dirty foam air filter will restrict air flow to the carburetor, reducing engine performance. If you operate the generator in very dusty areas, clean the foam air filter more frequently than specified in the Maintenance Schedule (see page 42). 1. Clean the air filter in warm soapy water, rinse, and allow to dry thoroughly, or clean in nonflammable solvent and allow to dry. 2.
31Z406030.book 51 ページ 2017年3月14日 火曜日 午後2時49分 SERVICING YOUR GENERATOR SPARK PLUG SERVICE In order to service the spark plug, you will need a spark plug wrench (commercially available). Spark plug: LR4C-E (NGK) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. An incorrect spark plug can cause engine damage. If the engine is hot, allow it to cool before servicing the spark plug. 1. Remove the spark plug maintenance cover. 2. Remove the spark plug cap.
31Z406030.book 52 ページ 2017年3月14日 火曜日 午後2時49分 SERVICING YOUR GENERATOR 5. Inspect the spark plug. Replace it if the electrodes are worn or if the insulator is cracked, chipped, or fouled. SIDE ELECTRODE SEALING WASHER 0.024–0.028 in (0.6–0.7 mm) 6. Measure the spark plug electrode gap with a wire-type feeler gauge. Correct the gap, if necessary, by carefully bending the side electrode. INSULATOR The gap should be: 0.024–0.028 in (0.6–0.7 mm) 7.
31Z406030.book 53 ページ 2017年3月14日 火曜日 午後2時49分 SERVICING YOUR GENERATOR SPARK ARRESTER SERVICE The spark arrester must be serviced every 100 hours to keep it functioning as designed. If the engine has been running, the muffler will be very hot. Allow the muffler to cool before servicing the spark arrester. Clean the spark arrester as follows: 1. Remove the four 5 mm screws, and remove the muffler protector. MUFFLER PROTECTOR 5 mm SCREWS 2.
31Z406030.book 54 ページ 2017年3月14日 火曜日 午後2時49分 SERVICING YOUR GENERATOR 3. Use a brush to remove carbon deposits from the spark arrester screen. Be careful to avoid damaging the screen. The spark arrester must be free of breaks and tears. Replace the spark arrester if it is damaged. 4. Check the muffler gasket; replace if damaged. Reinstall the muffler gasket, the spark arrester, the muffler, and the muffler protector in the reverse order of removal.
31Z406030.book 55 ページ 2017年3月14日 火曜日 午後2時49分 STORAGE STORAGE PREPARATION Proper storage preparation is essential for keeping your generator trouble-free and looking good. The following steps will help to keep rust and corrosion from impairing your generator’s function and appearance, and will make the engine easier to start when you use the generator again. Cleaning Wipe the generator with a moist cloth.
31Z406030.book 56 ページ 2017年3月14日 火曜日 午後2時49分 STORAGE Service according to the table below: STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required. 1 to 2 months Fill with fresh gasoline and add gasoline stabilizer*. 2 months to 1 year Fill with fresh gasoline and add gasoline stabilizer*. Turn the engine switch to the OFF position and drain the carburetor float bowl (see page 57). 1 year or more Drain the fuel tank and carburetor (see page 58).
31Z406030.book 57 ページ 2017年3月14日 火曜日 午後2時49分 STORAGE Draining the Carburetor Gasoline is highly flammable and explosive, and you can be burned or seriously injured when handling fuel. • Stop the engine and let it cool before handling fuel. • Keep heat, sparks, and flame away. • Handle fuel only outdoors. • Wipe up spills immediately. 1. Loosen the maintenance cover screw and remove the maintenance cover (see page 45). 2.
31Z406030.book 58 ページ 2017年3月14日 火曜日 午後2時49分 STORAGE Draining the Fuel Tank and Carburetor Gasoline is highly flammable and explosive, and you can be burned or seriously injured when handling fuel. • Stop the engine and let it cool before handling fuel. • Keep heat, sparks, and flame away. • Handle fuel only outdoors. • Wipe up spills immediately. 1. Unscrew the fuel filler cap (see page 43), remove the fuel filter, and empty the fuel tank into an approved gasoline container.
31Z406030.book 59 ページ 2017年3月14日 火曜日 午後2時49分 STORAGE Engine Oil Change the engine oil (see page 47). Engine Cylinder 1. Remove the spark plug (see page 51), and pour approximately one teaspoon (5 cc) of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil, and then reinstall the spark plug. 2. Reinstall the spark plug cap on the spark plug securely. 3. Reinstall the spark plug maintenance cover. 4.
31Z406030.book 60 ページ 2017年3月14日 火曜日 午後2時49分 STORAGE STORAGE PRECAUTIONS If your generator will be stored with gasoline in the fuel tank and carburetor, it is important to reduce the hazard of gasoline vapor ignition. Select a well ventilated storage area away from any appliance that operates with a flame, such as a furnace, water heater, or clothes dryer. Also avoid any area with a spark-producing electric motor, or where power tools are operated.
31Z406030.book 61 ページ 2017年3月14日 火曜日 午後2時49分 TRANSPORTING Do not lay the generator on its side when moving, storing, or operating it. Oil may leak and damage the engine or your property. If the generator has been used, allow it cool for at least 15 minutes before loading the generator on the transport vehicle. A hot engine and exhaust system can burn you and can ignite some material.
31Z406030.book 62 ページ 2017年3月14日 火曜日 午後2時49分 TAKING CARE OF UNEXPECTED PROBLEMS ENGINE WILL NOT START Possible Cause Fuel filler cap vent lever is in the OFF position. Engine switch is in the OFF position. Out of fuel. Bad fuel, generator stored without treating or draining gasoline, or refueled with bad gasoline. Low engine oil level caused Oil Alert to stop engine. Spark plug faulty, fouled, or improperly gapped. Spark plug wet with fuel (flooded engine).
31Z406030.book 63 ページ 2017年3月14日 火曜日 午後2時49分 TAKING CARE OF UNEXPECTED PROBLEMS ENGINE LACKS POWER Possible Cause Air filter restricted. Bad fuel, generator stored without treating or draining gasoline, or refueled with bad gasoline. Fuel filter restricted, carburetor malfunction, ignition malfunction, valves stuck, etc. Correction Clean or replace air filter (see pages 49, 50). Drain fuel tank and carburetor (see page 58). Refuel with fresh gasoline (see page 43).
31Z406030.book 64 ページ 2017年3月14日 火曜日 午後2時49分 TAKING CARE OF UNEXPECTED PROBLEMS NO POWER AT THE AC RECEPTACLES Possible Cause Output indicator is OFF, and overload indicator is ON. Faulty power tool or appliance. Faulty generator. Correction Check AC load. Stop and restart the engine. Check the cooling air inlet. Stop and restart the engine. Replace or repair power tool or appliance. Stop and restart the engine. Take the generator to an authorized Honda servicing dealer, or refer to the shop manual.
31Z406030.book 65 ページ 2017年3月14日 火曜日 午後2時49分 TECHNICAL INFORMATION Serial Number Location FRAME SERIAL NUMBER Record the frame serial number and date purchased in the spaces below. You will need this information when ordering parts and when making technical or warranty inquiries.
31Z406030.book 66 ページ 2017年3月14日 火曜日 午後2時49分 TECHNICAL INFORMATION Carburetor Modification for High Altitude Operation At high altitude, the standard carburetor air-fuel mixture will be too rich. Performance will decrease, and fuel consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting. Operation at an altitude that differs from that at which this engine was certified, for extended periods of time, may increase emissions.
31Z406030.book 67 ページ 2017年3月14日 火曜日 午後2時49分 TECHNICAL INFORMATION Emission Control System Information Source of Emissions The combustion process produces carbon monoxide, oxides of nitrogen, and hydrocarbons. Control of hydrocarbons and oxides of nitrogen is very important because, under certain conditions, they react to form photochemical smog when subjected to sunlight. Carbon monoxide does not react in the same way, but it is toxic.
31Z406030.book 68 ページ 2017年3月14日 火曜日 午後2時49分 TECHNICAL INFORMATION Problems That May Affect Emissions If you are aware of any of the following symptoms, have your engine inspected and repaired by your authorized Honda servicing dealer. • Hard starting or stalling after starting. • Rough idle. • Misfiring or backfiring under load. • Afterburning (backfiring). • Black exhaust smoke or high fuel consumption.
31Z406030.book 69 ページ 2017年3月14日 火曜日 午後2時49分 TECHNICAL INFORMATION Air Index (Models certified for sale in California) An Air Index Information label is applied to engines certified to an emission durability time period in accordance with the requirements of the California Air Resources Board. The bar graph is intended to provide you, our customer, the ability to compare the emissions performance of available engines. The lower the Air Index, the less pollution.
31Z406030.book 70 ページ 2017年3月14日 火曜日 午後2時49分 TECHNICAL INFORMATION Specifications Dimensions Model Description code Length Width Height Dry mass [weight] EU1000iT1 EAAT 17.8 in (451 mm) 9.5 in (242 mm) 14.9 in (379 mm) 29 lbs (13 kg) Engine Model Engine type Displacement [Bore × Stroke] Compression ratio Engine speed Cooling system Ignition system Engine oil capacity Fuel tank capacity Spark plug GXH50T 4-stroke, overhead valve, single cylinder 3.01 cu-in (49.4 cm3) [1.65 × 1.42 in (41.8 × 36.
EXCITER WINDING SUB WINDING MAIN WINDING DC WINDING Y Y Bu Bl/Bu ENGINE BLOCK IGNITION SPARK OIL LEVEL PULSE PLUG SWITCH GENERATOR G W/R Gr P R W Bu RECTIFIER Bl/R IGNITION COIL ENGINE GROUND G INVERTER BLOCK Br Br Bl GENERATOR BLOCK G INVERTER UNIT THROTTLE CONTROL MOTOR G/R G/Bl R/W R/Y G R R Y Bl Bl/Bu Bu G Y Bl Bl/Bu Bu G ECO THROTTLE OFF ON ON OFF Switch position AC OUTPUT RECEPTACLE Bl G Bl Bl/Bu Bu G G/Bl Y G/R R/W G R R R/W R/Y W/R Bl/R Bl G IGNITI
31Z406030.book 72 ページ 2017年3月14日 火曜日 午後2時49分 CONSUMER INFORMATION Dealer Locator Information To find an authorized Honda Servicing Dealer anywhere in the United States: Visit our website: http://powerequipment.honda.com/dealer-locator Honda Publications Shop Manual This manual covers complete maintenance and overhaul procedures. It is intended to be used by a skilled technician. Available through your Honda dealer or visit http://powerequipment.honda.
31Z406030.book 73 ページ 2017年3月14日 火曜日 午後2時49分 CONSUMER INFORMATION Customer Service Information Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership’s management. The Service Manager or General Manager can help. Almost all problems are solved in this way.
31Z406030.book 74 ページ 2017年3月14日 火曜日 午後2時49分 CONSUMER INFORMATION Distributor’s Limited Warranty This warranty is limited to the following Honda Power Equipment products when distributed by American Honda Motor Co., Inc., Power Equipment Division, 4900 Marconi Drive, Alpharetta, Georgia 30005. The following warranty applies to products purchased at retail or placed in rental service on or after January 1, 2010.
31Z406030.book 75 ページ 2017年3月14日 火曜日 午後2時49分 CONSUMER INFORMATION To Obtain Warranty Service: You must, at your expense, take the Honda Power Equipment product, accessory, replacement part, apparel, or the power equipment on which the accessory or replacement part is installed, and proof of purchase to any Honda Power Equipment dealer in the United States, Puerto Rico, or the U.S. Virgin Islands who is authorized to sell and/or service that product, during the dealer’s normal business hours.
31Z406030.book 76 ページ 2017年3月14日 火曜日 午後2時49分 CONSUMER INFORMATION Exclusions: 1.
31Z406030.book 77 ページ 2017年3月14日 火曜日 午後2時49分 CONSUMER INFORMATION Honda Parts, Accessories, and Apparel This warranty is limited to Honda Power Equipment parts, accessories, and apparel when distributed by American Honda Motor Co., Inc., 4900 Marconi Drive, Alpharetta, Georgia 30005-8847.
31Z406030.book 78 ページ 2017年3月14日 火曜日 午後2時49分 CONSUMER INFORMATION To Obtain Warranty Service: You must, at your expense, take the Honda Power Equipment part, accessory, or apparel, or the Honda Power Equipment on which the accessory or part is installed, and proof of purchase to any Honda Power Equipment dealer in the United States, Puerto Rico, or the U.S. Virgin Islands who is authorized to sell that product, during the dealer’s normal business hours.
31Z406030.book 79 ページ 2017年3月14日 火曜日 午後2時49分 CONSUMER INFORMATION Emission Control System Warranty Your new Honda Power Equipment engine complies with the U.S. EPA, Environment Canada, and State of California (models certified for sale in California only) emission regulations. American Honda Motor Co., Inc. provides the emission warranty coverage for engines in the United States and its territories. Honda Canada Inc.
31Z406030.book 80 ページ 2017年3月14日 火曜日 午後2時49分 CONSUMER INFORMATION Owner’s Warranty Responsibility As the power equipment engine owner, you are responsible for completing all required maintenance listed in your owner’s manual. Honda recommends that you retain all receipts covering maintenance on your power equipment engine, but Honda cannot deny warranty coverage solely for the lack of receipts or for your failure to ensure that all scheduled maintenance has been completed.
31Z406030.book 81 ページ 2017年3月14日 火曜日 午後2時49分 CONSUMER INFORMATION Warranty Coverage Honda power equipment engines sold in the United States and Canada are covered by this warranty for a period of two years from the date of delivery to the original retail purchaser or the length of the Honda Distributor’s Limited Warranty, whichever is longer. This warranty is transferable to each subsequent purchaser for the duration of the warranty period.
31Z406030.book 82 ページ 2017年3月14日 火曜日 午後2時49分 CONSUMER INFORMATION To Obtain Warranty Service You must, at your own expense, take your Honda Power Equipment engine or the product on which it is installed, along with your sales registration card or other proof of original purchase date, to any Honda Power Equipment dealer who is authorized by Honda to sell and service that Honda product during their normal business hours.
31Z406030.book 83 ページ 2017年3月14日 火曜日 午後2時49分 CONSUMER INFORMATION Disclaimer of Consequential Damage and Limitation of Implied Warranties American Honda Motor Co., Inc. and Honda Canada Inc. disclaim any responsibility for incidental or consequential damages such as loss of time or the use of the power equipment, or any commercial loss due to the failure of the equipment; and any implied warranties are limited to the duration of this written warranty.
31Z406030.book 84 ページ 2017年3月14日 火曜日 午後2時49分 INITIAL USE INSTRUCTIONS ENGINE OIL The generator is shipped WITHOUT OIL in the engine. 1. Place the generator on a level surface. 2. Loosen the maintenance cover screw and remove the maintenance cover. MAINTENANCE COVER SCREW MAINTENANCE COVER 3. With the generator in a level position, remove the oil filler cap. 4. Add enough SAE 10W-30 API service category SJ or later (or equivalent) oil to bring the oil level to the upper limit of the oil filler neck.
31Z406030.book 85 ページ 2017年3月14日 火曜日 午後2時49分 INITIAL USE INSTRUCTIONS FUEL Add fuel to the generator in a well-ventilated area. Never refuel the engine inside a building where gasoline fumes may reach flames or sparks. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, etc. Spilled fuel is not only a fire hazard, it causes environmental damage. Wipe up spills immediately.
31Z406030.book 86 ページ 2017年3月14日 火曜日 午後2時49分 INITIAL USE INSTRUCTIONS 2. Fuel carefully to avoid spilling fuel. Do not fill the fuel tank above the upper limit mark (red) on the fuel filter. UPPER LIMIT MARK (RED) FUEL FILTER Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel tank. Damage caused by spilled fuel is not covered under the Distributor’s Limited Warranty. 3. After refueling, tighten the fuel filler cap securely.
31Z406030.
31Z406030.book 88 ページ 2017年3月14日 火曜日 午後2時49分 INDEX A AC Applications .................................................................................. 29 AC OPERATION................................................................................... 27 AC PARALLEL OPERATION................................................................ 30 AC Parallel Operation Applications................................................... 32 AIR CLEANER SERVICE .......................................................
31Z406030.book 89 ページ 2017年3月14日 火曜日 午後2時49分 INDEX E Eco Throttle® Switch .......................................................................... 15 ECO THROTTLE® SYSTEM ................................................................ 37 Electric Shock Hazards ......................................................................... 7 Emission Control System Information.............................................. 67 Emission Control System Warranty..................................................
31Z406030.book 90 ページ 2017年3月14日 火曜日 午後2時49分 INDEX M MAINTENANCE SAFETY.................................................................... 41 MAINTENANCE SCHEDULE .............................................................. 42 N NO POWER AT THE AC RECEPTACLES............................................ 64 NO POWER AT THE DC RECEPTACLE .............................................. 64 O Oil Alert® Indicator ............................................................................. 18 OPERATION....
31Z406030.book 91 ページ 2017年3月14日 火曜日 午後2時49分 INDEX S SAFE OPERATING PRECAUTIONS.................................................... 21 SAFETY LABEL LOCATIONS................................................................ 9 Safety Precautions.............................................................................. 41 Serial Number Location ..................................................................... 65 SERVICING YOUR GENERATOR .......................................................
31Z406030.
EU1000i_OMcover_31Z40603_F QUICK REFERENCE INFORMATION The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. California Proposition 65 This product contains or emits chemicals known to the state of California to cause cancer, birth defects or other reproductive harm Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in closed areas.
EU1000i_OMcover_31Z40603_F Owner’s Manual GENERATOR EU1000i See page 84 for Initial Use Instructions 31Z40603 00X31-Z40-6030 PANTONE 186C K 背幅3mm AH 英 FM Hi Printed in Thailand C 2017 Honda Motor Co., Ltd.