04/06/28 11:18:49 31ZT7600_001 The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. The generator is a potential source of electrical shock if misused. Do not expose the generator to moisture, rain or snow. Do not let the generator get wet, and do not operate it with wet hands. Keep this owner’s manual handy, so you can refer to it at any time.
04/06/28 11:18:56 31ZT7600_002 Congratulations on your selection of a Honda generator. We are certain you will be pleased with your purchase of one of the finest generators on the market. We want to help you get the best results from your new generator and to operate it safely. This manual contains the information on how to do that; please read it carefully. As you read this manual, you will find information preceded by a symbol.
04/06/28 11:19:09 31ZT7600_003 A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important. And using this generator safely is an important responsibility. To help you make informed decisions about safety, we have provided operating procedures and other information on labels and in this manual. This information alerts you to potential hazards that could hurt you or others.
05/12/26 16:16:59 31ZT7600_004 CONTENTS SAFETY ....................................................................................................... 5 Safety Label Locations ........................................................................ 5 Safety Information ............................................................................... 7 COMPONENT IDENTIFICATION ............................................................... 9 CONTROLS ...........................................................
04/06/28 11:19:16 31ZT7600_005 MAINTENANCE ....................................................................................... 38 The Importance of Maintenance ....................................................... 38 Maintenance Safety ........................................................................... 39 Emission Control System Information ............................................. 40 Air Index ..............................................................................................
04/06/28 11:19:25 31ZT7600_006 SAFETY SAFETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda generator dealer for a replacement.
04/06/28 11:19:35 31ZT7600_007 6
04/06/28 11:19:44 31ZT7600_008 SAFETY INFORMATION Honda generators are designed to give safe and dependable service if operated according to instructions. Read and understand this owner’s manual before operating your generator. You can help prevent accidents by being familiar with your generator’s controls, and by observing safe operating procedures. Operator Responsibility Know how to stop the generator quickly in case of emergency.
04/06/28 11:19:54 31ZT7600_009 Electric Shock Hazards The generator produces enough electric power to cause a serious shock or electrocution if misused. Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution. Keep the generator dry. If the generator is stored outdoors, unprotected from the weather, check all of the electrical components on the control panel, before each use.
04/06/28 11:20:01 31ZT7600_010 COMPONENT IDENTIFICATION OUTPUT INDICATOR LIGHT PARALLEL OPERATION OUTLETS DC CIRCUIT PROTECTOR DC RECEPTACLE AC CIRCUIT PROTECTOR OVERLOAD INDICATOR LIGHT OIL ALERT INDICATOR LIGHT ENGINE SWITCH CHOKE KNOB FUEL VALVE LEVER AC RECEPTACLES ECOTHROTTLETM SWITCH <STAND TYPE> <WHEEL TYPE> 9
04/06/28 11:20:09 31ZT7600_011 SPARK PLUG CAP MUFFLER FRONT HANDLE OIL FILLER CAP/ DIPSTICK OIL DRAIN PLUG AIR CLEANER OIL MAINTENANCE COVER FRAME SERIAL NUMBER LEFT-SIDE MAINTENANCE COVER FUEL TANK CAP STARTER GRIP REAR HANDLE GROUND TERMINAL Record the frame serial number for your future reference. Refer to this serial number when ordering parts, and when making technical or warranty inquiries (see page 65 ).
04/06/28 11:20:16 31ZT7600_012 CONTROLS ENGINE SWITCH To start and stop the engine. Key position: To stop the engine. Key can be removed/inserted. OFF: To run the engine after starting. ON: To start the engine by operating the starter motor. START: OFF ON START ENGINE SWITCH Return the key to the ON position once the engine has started. Do not use the starter for more than 5 seconds at a time. If the engine fails to start, release the switch and wait 10 seconds before operating the starter again.
04/06/28 11:20:23 31ZT7600_013 RECOIL STARTER To start the engine, pull the starter grip lightly until resistance is felt, then pull briskly. Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter. STARTER GRIP FUEL VALVE LEVER The fuel valve is located on the control panel. When the fuel valve lever is in the ON position, fuel is allowed to flow from the fuel tank to the carburetor.
04/06/28 11:20:34 31ZT7600_014 CHOKE KNOB The choke knob opens and closes the choke valve in the carburetor. Pulling the choke knob to the CLOSED position enriches the fuel mixture for starting a cold engine. Pushing the choke knob to the OPEN position provides the correct fuel mixture for operation after starting, and for restarting a warm engine. CHOKE KNOB CLOSED OPEN ECOTHROTTLETM SWITCH The EcoThrottleTM system automatically reduces engine speed when all loads are turned off or disconnected.
04/06/28 11:20:40 31ZT7600_015 OUTPUT INDICATOR LIGHT The output indicator light (green) is illuminated when the generator is operating normally. It indicates that the generator is producing electrical power at the receptacles. OUTPUT INDICATOR LIGHT (GREEN) OVERLOAD INDICATOR LIGHT If the generator is overloaded (see page 64 ), or if there is a short circuit in a connected appliance, or if the inverter is overheated, the overload indicator light (red) will go ON.
05/12/26 16:17:07 31ZT7600_016 OIL ALERT SYSTEM The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert indicator light comes on and the Oil Alert system will automatically stop the engine (the engine switch will remain in the ON position).
04/06/28 11:20:56 31ZT7600_017 AC CIRCUIT PROTECTOR The AC circuit protectors will automatically switch OFF if there is a short circuit or a significant overload of the generator at the 120V 20A locking plug, or 120V 30A locking plug receptacle. If an AC circuit protector switches OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the AC circuit protector ON.
04/06/28 11:21:01 31ZT7600_018 GROUND TERMINAL The generator ground terminal is connected to the frame of the generator, the metal non-current-carrying parts of the generator, and the ground terminals of each receptacle. Before using the ground terminal, consult a qualified electrician, electrical inspector or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.
05/12/26 16:17:14 31ZT7600_019 GENERATOR USE CONNECTIONS TO A BUILDING ELECTRICAL SYSTEM Connections for standby power to a building electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes. A transfer switch, which isolates generator power from utility power, is available through authorized Honda generator dealers.
05/12/26 16:17:20 31ZT7600_020 SPECIAL REQUIREMENTS Keep all cooling holes open and not blocked by debris, mud, water, etc. Cooling holes are located on the side panel, the control panel, and the bottom of the generator. If the cooling holes are blocked, the generator may overheat and damage the engine, inverter, or windings. Do not lay the generator on its side when moving, storing, or operating it. Oil may leak and damage the engine or your property.
05/12/26 16:17:29 31ZT7600_021 AC APPLICATIONS Before connecting an appliance or power cord to the generator: Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock. If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is the appliance, or if the rated load capacity of the generator has been exceeded.
05/12/26 16:17:37 31ZT7600_022 AC OPERATION 1. Start the engine and make sure the output indicator light (green) comes on (see page 35 and 36 ). 2. Plug in the appliance. Most motorized appliances require more than their rated wattage for startup. PLUG OUTPUT INDICATOR LIGHT (GREEN) OVERLOAD INDICATOR LIGHT (RED) If the generator is overloaded (see page 19 ), or if there is a short circuit in a connected appliance, or if the inverter is overheated, the overload indicator light (red) will come ON.
05/12/26 16:17:40 31ZT7600_023 When an electric motor is started, the overload indicator light (red) may come on. This is normal if the overload indicator light (red) goes off after about four (4) seconds. If the overload indicator light (red) stays on, consult your Honda generator dealer.
05/12/26 16:17:49 31ZT7600_024 AC PARALLEL OPERATION APPLICATIONS Before connecting an appliance or power cord to the generator: Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock. If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is the appliance, or if the rated load capacity of the generator has been exceeded.
05/12/26 16:17:53 31ZT7600_025 For continuous operation, do not exceed the rated power. Rated power in parallel operation is: 5.6 kVA The total power requirements (VA) of all appliances connected must be considered. Appliance and power tool manufacturers usually list rating information near the model number or serial number.
05/12/26 16:18:00 31ZT7600_026 AC PARALLEL OPERATION 1. Connect the parallel operation kit between the two EU3000is generators following the instructions supplied with the kit. PARALLEL OPERATION KIT (optional equipment) 2. Start the generators and make sure the output indicator lights (green) come on (see pages 35 and 36 ). 3. Plug in the appliance following the instructions provided with the parallel operation kit. Most motorized appliances require more than their rated wattage for startup.
04/06/28 11:22:03 31ZT7600_027 DC OPERATION The DC receptacle should ONLY be used for charging 12-volt automotive type batteries. DC output will vary according to the position of the EcoThrottleTM switch. When the EcoThrottleTM switch is turned to the ON position and the AC output is not used, the DC current will be about one-third of the rated current.
04/06/28 11:22:09 31ZT7600_028 2. Plug the battery charging cable into the DC receptacle of the generator. 3. Connect the red lead of the battery charging cable to the positive (+) battery terminal and the black lead to the negative (−) battery terminal.
04/06/28 11:22:19 31ZT7600_029 4. Start the generator. Do not start the vehicle while the battery charging cable is connected and the generator is running. The vehicle or the generator may be damaged. An overloaded DC circuit, excessive current drawn by the battery, or a wiring problem will trip the DC circuit protector (the yellow indicator inside the clear circuit protector button will pop out). If this happens, wait a few minutes before pushing in the circuit protector button to resume operation.
04/06/28 11:22:26 31ZT7600_030 ECOTHROTTLETM SYSTEM With the switch in the ON position, engine speed is automatically lowered when loads are reduced, turned OFF or disconnected. When appliances are turned ON or reconnected, the engine returns to the proper speed to power the electrical load. In the OFF position, the EcoThrottleTM system does not operate. Appliances with large start-up power demands may not allow the engine to reach normal operating rpm when they are connected to the generator.
04/06/28 11:22:32 31ZT7600_031 HIGH ALTITUDE OPERATION At high altitude, the standard carburetor air/fuel mixture will be too rich. Performance will decrease, and fuel consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting. Operation at an altitude that differs from that at which this engine was certified, for extended periods of time, may increase emissions. High altitude performance can be improved by specific modifications to the carburetor.
04/06/28 11:22:45 31ZT7600_032 PRE-OPERATION CHECK ENGINE OIL Engine oil is a major factor affecting engine performance and service life. Non detergent and 2-stroke engine oils will damage the engine and are not recommended. SAE Viscosity Grades Check the oil level BEFORE EACH USE with the generator on a level surface and the engine stopped. Use 4-stroke motor oil that meets or exceeds the requirements for API service classification SJ.
04/06/28 11:22:53 31ZT7600_033 REFUELING Fuel tank capacity: 3.43 US gal (13.0 ) With the engine stopped, check the fuel level gauge. Refill the fuel tank if the fuel level is low. Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. Stop the engine and keep heat, sparks, and flame away. Handle fuel only outdoors. Wipe up spills immediately. Refuel in a well-ventillated area with the engine stopped. If the engine has been running, allow it to cool first.
04/06/28 11:23:00 31ZT7600_034 FUEL RECOMMENDATIONS Use unleaded gasoline with a pump octane rating of 86 or higher. This engine is certified to operate on unleaded gasoline. Unleaded gasoline produces fewer engine and spark plug deposits and extends exhaust system life. Never use stale or contaminated gasoline or an oil/gasoline mixture. Avoid getting dirt or water in the fuel tank. Occasionally you may hear a light ‘‘spark knock’’ or ‘‘pinging’’ (metallic rapping noise) while operating under heavy loads.
04/06/28 11:23:10 31ZT7600_035 Oxygenated Fuels Some conventional gasolines are being blended with alcohol or an ether compound. These gasolines are collectively referred to as oxygenated fuels. To meet clean air standards, some areas of the United States and Canada use oxygenated fuels to help reduce emissions. If you use an oxygenated fuel, be sure it is unleaded and meets the minimum octane rating requirement. Before using an oxygenated fuel, try to confirm the fuel’s contents.
04/06/28 11:23:19 31ZT7600_036 STARTING THE ENGINE Electric starting: 1. Make sure that all appliances are disconnected from the AC receptacles. 2. Turn the fuel valve lever to the ON position. 3. To start a cold engine, pull the choke knob out to the CLOSED position. To restart a warm engine, leave the choke knob in the OPEN position. 4. Turn the engine switch to the START position and hold it there for 5 seconds or until the engine starts.
04/06/28 11:23:28 31ZT7600_037 Manual starting: 1. Make sure that all appliances are disconnected from the AC receptacles. 2. Turn the fuel valve lever to the ON position. 3. To start a cold engine, pull the choke knob out to the CLOSED position. To restart a warm engine, leave the choke knob in the OPEN position. 4. Turn the engine switch to the ON position. 5. Pull the starter grip lightly until resistance is felt, then pull briskly. Do not allow the starter grip to snap back against the engine.
04/06/28 11:23:35 31ZT7600_038 STOPPING THE ENGINE In an emergency: 1. To stop the engine in an emergency, turn the engine switch to the OFF position. In normal use: 1. Unplug appliances from the generator receptacles. If applicable for parallel operation, unplug the appliance from the parallel operation kit. 2. Turn the engine switch to the OFF position. 3. Turn the fuel valve lever to the OFF position. 4.
04/06/28 11:23:42 31ZT7600_039 MAINTENANCE THE IMPORTANCE OF MAINTENANCE Good maintenance is essential for safe, economical, and troublefree operation. It will also help reduce air pollution. Improper maintenance, or failure to correct a problem before operation, can cause a malfunction in which you can be seriously hurt or killed. Always follow the inspection and maintenance recommendations and schedules in this owner’s manual.
04/06/28 11:23:52 31ZT7600_040 MAINTENANCE SAFETY Some of the most important safety precautions follow. However, we cannot warn you of every conceivable hazard that can arise in performing maintenance. Only you can decide whether or not you should perform a given task. Failure to properly follow maintenance instructions and precautions can cause you to be seriously hurt or killed. Always follow the procedures and precautions in the owner’s manual.
04/06/28 11:24:00 31ZT7600_041 EMISSION CONTROL SYSTEM INFORMATION Source of Emissions The combustion process produces carbon monoxide, oxides of nitrogen, and hydrocarbons. Control of hydrocarbons and oxides of nitrogen are very important because, under certain conditions, they react to form photochemical smog when subjected to sunlight. Carbon monoxide does not react in the same way, but it is toxic.
04/06/28 11:24:07 31ZT7600_042 Problems That May Affect Emissions If you are aware of any of the following symptoms, have your engine inspected and repaired by your servicing dealer. Hard starting or stalling after starting. Rough idle. Misfiring or backfiring under load. Afterburning (backfiring). Black exhaust smoke or high fuel consumption. Replacement Parts The emission control systems on your Honda engine were designed, built, and certified to conform with EPA and California emission regulations.
04/06/28 11:24:14 31ZT7600_043 AIR INDEX An Air Index Information hang tag/label is applied to engines certified to an emission durability time period in accordance with the requirements of the California Air Resources Board. The bar graph is intended to provide you, our customer, the ability to compare the emissions performance of available engines. The lower the Air Index, the less pollution.
04/06/28 11:24:28 31ZT7600_044 MAINTENANCE SCHEDULE REGULAR SERVICE PERIOD (3) ITEM Perform at every indicated month or o per ati ng h our int erv al, whichever comes first. Engine oil Check level Change Air filter Check Clean Replace Sediment cup Clean Spark plug Check-adjust Replace Spark arrester Clean Valve clearance Check-adjust Combustion Clean chamber Fuel tank and filter Clean Fuel line Check Each use First month or 20 Hrs. Every Every Every 3 months 6 months year or or or 50 Hrs. 100 Hrs.
04/06/28 11:24:39 31ZT7600_045 ENGINE OIL CHANGE Drain the oil while the engine is warm to assure rapid and complete draining. 1. Open and remove the oil maintenance cover. 2. Remove the drain plug and sealing washer, remove the oil filler cap, and drain the oil. 3. Reinstall the drain plug and sealing washer. Tighten the plug securely. 4. Refill with the recommended oil (see page 31 ) and check the oil level. 5. Reinstall, close and latch the oil maintenance cover. Oil capacity: 0.58 US qt (0.
04/06/28 11:24:49 31ZT7600_046 AIR CLEANER SERVICE A dirty air filter will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas. Using gasoline or flammable solvent to clean the air filter can cause a fire or explosion. Use only soapy water or nonflammable solvent. Never run the generator without the air filter. Rapid engine wear will result. 1.
04/06/28 11:24:57 31ZT7600_047 c. Soak the foam air filter in clean engine oil and squeeze out the excess oil. The engine will smoke during initial startup if too much oil is left in the foam air filter. d. Reinstall the foam air filter to the air cleaner cover. PAPER AIR FILTER 4. Paper air filter: If the paper air filter is dirty, replace it with a new one. Do not clean the paper air filter. AIR CLEANER COVER 5. Reinstall the air cleaner cover. 6. Close and latch the left-side maintenance cover.
04/06/28 11:25:09 31ZT7600_048 SPARK PLUG SERVICE In order to service the spark plug, you will need a spark plug wrench (commercially available). Recommended spark plugs: BPR5ES (NGK) W16EPR-U (DENSO) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. An incorrect spark plug can cause engine damage. If the engine has been running, the muffler will be very hot. Be careful not to touch the muffler. 1. Open the left-side maintenance cover. 2.
05/12/26 16:18:10 31ZT7600_049 6. Visually inspect the spark plug. Discard it if the insulator is cracked, chipped or fouled. 7. Measure the spark plug electrode gap with a wire-type feeler gauge. Correct the gap, if necessary, by carefully bending the side electrode. The gap should be: 0.028−0.031 in (0.70−0.80 mm) 0.028−0.031 in (0.70−0.80 mm) SEALING WASHER 8. Check that the spark plug sealing washer is in good condition, and thread the spark plug in by hand to prevent cross-threading. 9.
04/06/28 11:25:24 31ZT7600_050 FUEL SEDIMENT CUP CLEANING The sediment cup prevents dirt or water which may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned. 1. Turn the engine switch to the OFF position. 2. Turn the fuel valve lever to the OFF position. 3. Open the left-side maintenance cover. 4. Remove the air cleaner cover and paper air filter (see page 45 ). 5. Disconnect the breather hose from the air cleaner base. 6.
04/06/28 11:25:29 31ZT7600_051 7. Remove the sediment cup by turning it counterclockwise. 8. Clean the sediment cup, O-ring, and filter in nonflammable or high flash point solvent. 9. Reinstall the filter, O-ring, and sediment cup. 10.Reinstall the air cleaner base, and connect the breather hose with the air cleaner base. 11.Reinstall the paper air filter and air cleaner cover. 12.Close and latch the left-side maintenance cover.
04/06/28 11:25:38 31ZT7600_052 SPARK ARRESTER MAINTENANCE If the generator has been running, the muffler will be very hot. Allow it to cool before proceeding. The spark arrester must be serviced every 100 hours to maintain its efficiency. 1. Remove the four 6 mm cap nuts, and remove the rear cover. 2. Remove the four 6 mm bolts, and remove the upper muffler protector. 6 mm BOLTS UPPER MUFFLER PROTECTOR REAR COVER 6 mm CAP NUTS 3. Remove the four 8 mm bolts, and remove the rear handle. 4.
04/06/28 11:25:45 31ZT7600_053 6. Remove the three 5 mm bolts, and remove the exhaust tail pipe and the spark arrester. EXHAUST TAIL PIPE SPARK ARRESTER 5 mm BOLTS 7. Use a brush to remove carbon deposits from the spark arrester screen. 8. Inspect the screen for breaks or tears and replace it if necessary. 9. Install the spark arrester and the exhaust tail pipe in the reverse order of removal.
04/06/28 11:25:54 31ZT7600_054 10.Install the lower muffler protector, the rear under plate and the rear handle in the reverse order of removal. LOWER MUFFLER PROTECTOR HOOK LOWER MUFFLER PROTECTOR REAR HANDLE HOOK REAR UNDER PLATE LOWER MUFFLER PROTECTOR HOOK Install the lower muffler protector inside the hook securely. 11.Install the upper muffler protector and the rear cover in the reverse order of removal.
05/12/26 16:18:19 31ZT7600_055 BATTERY The generator’s engine has a 0.5 amp charging system to charge the battery while the engine is running. If the generator is only used periodically, the battery must be charged monthly to maintain the battery service life. A lead acid battery self discharges at a rate of 0.5−1.0% per day. This means that the battery, if the generator is not operated in a month, can discharge as much as 30% in the same period.
04/06/28 11:26:15 31ZT7600_056 Charging: The battery is rated at 8Ah (ampere-hours). Charging current should equal 10% of the battery’s ampere-hour rating. A battery charger should be used that can be adjusted to deliver 0.8 amps. The battery gives off explosive gasses; keep sparks, flames and cigarettes away from the battery while charging. Provide adequate ventilation when charging. The battery contains sulfuric acid (electrolyte). Contact with skin or eyes may cause severe burns.
04/06/28 11:26:18 31ZT7600_057 Installation: 1. Install the battery in the generator. 2. Install the positive (+) cable to the battery positive (+) terminal; then install the negative (−) cable to the battery negative (−) terminal. 3. Install the battery holder band. 4. Install the front cover, and install the four 6 mm cap nuts.
04/06/28 11:26:26 31ZT7600_058 FUSE REPLACEMENT If the fuse is blown, the starter motor won’t operate. 1. Turn the engine switch to the OFF position. 2. Remove the four 6 mm cap nuts and the front cover. FRONT COVER 6 mm CAP NUTS 3. Remove the fuse holder cover and replace the fuse. The specified fuse is 5A. FUSE HOLDER If frequent fuse failure occurs, determine the cause and correct the problem before attempting to operate the generator further.
05/12/26 16:18:24 31ZT7600_059 TRANSPORTING/STORAGE TRANSPORTING Do not lay the generator on its side when moving, storing, or operating it. Oil may leak and damage the engine or your property. If the generator has been used, allow it cool for at least 15 minutes before loading the generator on the transport vehicle. A hot engine and exhaust system can burn you and can ignite some material.
04/06/28 11:26:38 31ZT7600_060 STORAGE Before storing the unit for an extended period: 1. Be sure the storage area is free of excessive humidity and dust. 2. Service according to the table below: STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required Fill with fresh gasoline and add gasoline 1 to 2 months conditioner *. Fill with fresh gasoline and add gasoline 2 months to 1 year conditioner *. Drain the carburetor float bowl. (page 60).
04/06/28 11:26:46 31ZT7600_061 Storage Procedure 1. Drain the carburetor and the fuel sediment cup. a. Open the left-side maintenance cover. b.Loosen the carburetor drain screw. c. Drain the gasoline from the carburetor into a suitable container. d.Tighten the carburetor drain screw. e. Drain the fuel sediment cup (see page 49). f. Close the left-side maintennance cover. Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel.
04/06/28 11:26:56 31ZT7600_062 TROUBLESHOOTING When the engine will not start: NO Is there fuel in the tank? Refill the fuel tank. YES Is there enough oil NO in the engine? Add the recommended oil. YES Is the spark plug in NO good condition? YES Is the fuel reaching NO the carburetor? Readjust gap and dry the spark plug. Replace it if necessary. Clean the fuel sediment cup. YES If the engine still does not start, take the generator to an authorized Honda generator dealer.
04/06/28 11:27:05 31ZT7600_063 Appliance does not operate: Is the output indicator light ON? YES NO Is the overload indicator light ON? NO Take the generator to an authorized Honda generator dealer. YES NO DEFECTS Check the electrical appliance or equipment for any defects. DEFECTS Take the generator to an authorized Honda generator dealer. Replace the electrical appliance or equipment. Take the electrical appliance or equipment to an electrical shop for repair. Stop and restart the engine.
04/06/28 11:27:21 31ZT7600_064 WIRING DIAGRAM 63
05/12/26 16:32:44 31ZT7600_065 SPECIFICATIONS Dimensions Model (Type) Power product description code Length Width Height Dry weight EU3000is (Stand type) EU3000is (Wheel type) EZGF 25.8 in (655 mm) 17.5 in (445 mm) 18.9 in (480 mm) 21.9 in (555 mm) 22.4 in (570 mm) 130.1 lbs (59.0 kg) 134.5 lbs (61.
04/06/28 11:27:46 31ZT7600_066 CUSTOMER SERVICE INFORMATION Servicing dealership personnel are trained professionals. They should be able to answer any questions you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership’s management. The Service Manager or General Manager can help. Almost all problems are solved in this way.
05/12/26 16:32:49 31ZT7600_067 INDEX COMPONENT IDENTIFICATION ............................................................... 9 CONTENTS ................................................................................................. 3 CONTROLS ............................................................................................... 11 AC Circuit Protector ........................................................................... 16 Choke knob .......................................................
04/06/28 11:27:53 31ZT7600_068 PRE-OPERATION CHECK ........................................................................ 31 Engine Oil ........................................................................................... 31 Fuel Recommendations ..................................................................... 33 Refueling ............................................................................................. 32 SAFETY ......................................................................
04/06/28 11:27:55 31ZT7600_069 MEMO 68