Owner's Manual

DC Operation
The DC terminals may ONLY be used for charging 12 volt automotive-type
batteries.
Connecting the battery cables:
1. Before connecting charging cables to a battery that is installed in a vehicle,
disconnect the vehicle’s ground cable from the battery.
m The battery gives off explosive gases; keep sparks, flames
and cigarettes away. Provide adequate ventilation when charging or
using batteries.
2. Connect the positive (+) battery cable to the battery positive (+) terminal.
3. Connect the other end of the positive (+) battery cable to the generator
positive (+) terminal.
4. Connect the negative (-)-battery cable to the battery negative (-) terminal.
5. Connect the other end of the negative (-) battery cable to the generator
negative (-) terminal.
6. Start the generator.
pmicq
Do not start the vehicle white the battery charging cables
are connected and the generator is running. The vehicle or the generator
may be damaged.
An overloaded DC circuit, excessive current draw by the battery, or a wiring
problem will trip the DC circuit breaker (PUSH button extends out). If this
happens, wait a few minutes before pushing in the circuit breaker to resume
operation. If the circuit breaker continues to go OFF, discontinue charging
and see your authorized Honda generator dealer.
17