Instruction Manual

12
ENGLISH
Battery Connections
Use the following materials to connect a 12-volt battery to the starter
on TYPE 7 units (electric start with engine-mounted starter switch/
manual choke control/preset throttle):
Battery – 12-volt lead acid battery with a recommended ampere-hr
rating of 3 Ah or a 14.4-volt NiCd battery with a recommended
ampere-hr rating of 1.7 Ah.
Wire – 12-gauge (minimum) wire with a maximum length of 10 ft
(3 meters).
Fuse – 40-ampere blade type fuse.
Terminal – Delphi 56 series male connector and terminal to
connect to the starter motor.
Coat the battery terminals and cable ends with dielectric grease. Be
careful not to connect the battery in reverse polarity.
WARNING: Battery posts, terminals and related accessories contain
lead and lead compounds. Wash hands after handling.
1. Connect the battery positive (+) cable using the appropriate
connector and insulator to the supplied starter connector.
2. Connect the battery negative (-) cable to an engine mounting bolt,
frame bolt, or the provided ground position on the starter motor
(requires 5 x 8 mm screw).
3. Connect the battery positive (+) cable to the battery positive (+)
terminal as shown.
4. Connect the battery negative (-) cable to the battery negative (-)
terminal as shown.
The following diagram only shows connections for TYPE 7 units
(electric start with engine-mounted starter switch/manual choke
control/preset throttle). Connections are different for the other
electric starter types (TYPES 4 and 6).
This engine is not equipped with a charging system to keep the
battery charged during engine operation. The battery will loose
charge during starter motor operation only. There is no drain on the
battery once the engine is running.
The battery must be charged by an external battery charging system.
Refer to the equipment manufacturer’s instructions or the battery
manufacturer for specific external battery charging recommendations.
Wiring Diagrams
WARNING
A battery can explode if you do not follow the correct
procedure, seriously injuring anyone nearby.
Keep all sparks, open flames, and smoking materials away
from the battery.
BATTERY
NEGATIVE (-)
CABLE
BATTERY
NEGATIVE (-)
TERMINAL
BATTERY
BATTERY POSITIVE
(+) TERMINAL
STARTER
MOTOR
40 AMP FUSE
STARTER MOTOR
POSITIVE (+) CONNECTOR
(from starter switch)
STARTER GROUND (-)
CONNECTION
BATTERY POSITIVE (+)
CABLE
IGNITION
COIL
SPARK
PLUG
ENGINE STOP
SWITCH
RECOIL STARTER
(All Types)
IGNITION
COIL
SPARK
PLUG
STARTER
MOTOR
STARTER
SWITCH
FUSE
(40A)
ELECTRIC STARTER
(TYPE 6 with Blade Brake Clutch)
Supplied by equipment
manufacturer.
BATTERY
ENGINE STOP
SWITCH
SPARK
PLUG
STARTER
SWITCH
BATTERY
IGNITION
COIL
ELECTRIC STARTER
(TYPE 4 with Flywheel Brake)
FUSE
(40A)
STARTER
MOTOR
Supplied by equipment
manufacturer.
SPARK
PLUG
STARTER
MOTOR
STARTER
SWITCH
FUSE
(40A)
BATTERY
ELECTRIC STARTER
(TYPE 7 with Starter Switch on the engine)
Supplied by equipment
manufacturer.
STARTER SWITCH
IGNITION
COIL