Owner's Manual

3. BATTERY CONNECTIONS (For electric starter)
Use a 12 volt battery with an ampere-hour rating of at least 28 AH.
Connect the battery posive (+) cable to the starter solenoid terminal, as
shown.
Connect the battery negative (-1 cable to an engine mounting bolt, frame
bolt, or other good engine ground connection.
Check the battery cable connections to be sure the cables are tightened
and free of corrosion. Remove any corrosion with a wire brush and coat
the terminals and cable ends with grease.
NEGATIVE i-1
BATTERY CABLE
STARTER SOLENOID
POSITIVE ( + )
BATTERY CABLE
m
Batteries produce explosive gases. Keep sparks, flames, and
cigarettes away. Always shield the eyes when working near batteries.