4. Wipe dirt from the inside of the air cleaner case (5) and cover, using a moist
rag. Be careful to prevent dirt from entering the clean chamber that leads to
the carburetor.
5. Reinstall the air cleaner elements and the cover.
:
Tighten the two air cleaner cover bolts securely.
:
Hook the latch tabs (1b) securely.
Do not allow dust, dirt, and debris to enter the clean chamber
(air cleaner case) when servicing the air cleaner.
6.4.4 F
UEL FILTER MAINTENANCE
Gasoline is extremely flammable and is esplosive under
certain conditions. Do not smoke or allow flames or sparks in the area.
Check the fuel filter for water accu-
mulation or sediment.
If the fuel filter contains water accu-
mulation or sediment, take the
engine to your authorized Honda
engine dealer.
6.4.5 S
PARK PLUG SERVICE
Recommended spark plugs:
: BPR5ES (NGK) - W16EPR-U (DENSO).
: ZGR5A (NGK) - J16CR-U (DENSO)
Never use a spark plugs of incorrect heat range.