3.  BATTERY  CONNECTIONS  (for  electric  starter) 
Use a 12 volt  battery  with  an  ampere-hour  rating  of at  least  18 AH. 
Connect  the  battery  positive  (+)  cable  to  the  starter  solenoid  terminal  as 
shown. 
Connect  the  battery  negative  (-1  cable  to  an engine  mounting  bolt,  frame 
bolt,  or  other  good  engine  ground  connection. 
Check  the  battery  cable  connections  to  be sure the  cables  are  secured  and 
free  of  corrosion.  Remove  any  corrosion  and  coat  the  terminals  and  cable 
ends  with  grease. 
m 
l 
The  battery  gives  off  explosive  gases;  keep  sparks,  flames  and  cigaret- 
tes  away.  Provide  adequate  ventilation  when  charging  or  using  batteries 
in  an  enclosed  space. 
l 
The  battery  contains  sulfuric  -a&d  (electrolyte).  Contact  with  skin  or 
eyes  may  cause  severe  burns.  Wear  protective  clothing  and  a  face 
shield. 
-  If  electrolyte  gets  on  your  skin,  flush  with  water. 
-  If  electrolyte  gets  in  your’  eyes,  flush  with  water  for  at  least  15 
minutes  and  call  a  physician  immediately. 
l 
Electrolyte  is  poisonous. 
-  If  swallowed,  drink  large  quantities  of  water  or  milk  and  follow  with 
milk  of  magnesia  or  vegetable  oil  and  call  a physician. 
.  KEEP  OUT  OF  REACH  OF  CHILDREN. 
CAUTION: 
l 
Use  only  distilled  water  in  the  battery.  Tap  water  will  shorten  the  service 
life  of  the  battery. 
l 
Filling  the  battery  above  the  UPPER  LEVEL  line  may  cause  the  electrolyte 
to  overflow,  resulting  in  corrosion  to  engine  or  nearby  parts.  Immediate- 
ly  wash  off  any  spilled  electrolyte. 
l 
Do  not  connect  the  battery  in  reverse  polarity  as  this  will  short  circuit 
the  battery  charging  system  and  trip  the  circuit  breaker. 
NEGATIVE  (-1  .’ 
BATTERY  CABLE 
STARTER 
SOLENOID 
SITIVE  (+)  BATTERY  CABLE 