Owner’s Manual GENERATOR EM5000SX/EM6500SX See page 12 for instructions on assembling your generator. See page 17 for Initial Use Instructions. 31Z23620 00X31-Z23-6200 PANTONE 186C K 背幅3mm AH 英 N Hi FM Printed in China C 2020 Honda Motor Co., Ltd.
31Z236200.book 0 ページ 2020年2月20日 木曜日 午後1時8分 The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in enclosed or partly enclosed areas. Breathing carbon monoxide can cause unconsciousness or death. Never run this product's engine in an enclosed, or even partly enclosed area.
1Z236200.book 1 ページ 2020年2月20日 木曜日 午後1時8分 INTRODUCTION Thank you for purchasing a Honda generator. We would like to help you get the best results from your new generator and to operate it safely. This manual contains the information on how to do that; please read it carefully. We suggest you read the "Distributor’s Limited Warranty" (see page 98) to fully understand its coverage and your responsibilities of ownership.
31Z236200.book 2 ページ 2020年2月20日 木曜日 午後1時8分 INTRODUCTION A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important. We have provided important safety messages in this manual and on the generator. This information alerts you to potential hazards that could hurt you or others. Please read these messages carefully. Of course, it is not practical or possible to warn you about all the hazards associated with operating or maintaining a generator. You must use your own good judgment.
31Z236200.book 3 ページ 2020年2月20日 木曜日 午後1時8分 CONTENTS INTRODUCTION ................................................................................................ 1 GENERATOR SAFETY ........................................................................................ 7 IMPORTANT SAFETY INFORMATION................................................................................ 7 Operator Responsibility...................................................................................................
31Z236200.book 4 ページ 2020年2月20日 木曜日 午後1時8分 CONTENTS FEATURES ................................................................................................................................34 Oil Alert® System ..............................................................................................................34 Automatic Engine Stop Function...............................................................................34 Auto Choke and Throttle Control System..................................
31Z236200.book 5 ページ 2020年2月20日 木曜日 午後1時8分 CONTENTS SERVICING YOUR GENERATOR ...................................................................... 63 THE IMPORTANCE OF MAINTENANCE...........................................................................63 MAINTENANCE SAFETY ......................................................................................................64 Safety Precautions...........................................................................................................
31Z236200.book 6 ページ 2020年2月20日 木曜日 午後1時8分 CONTENTS TECHNICAL INFORMATION ............................................................................ 87 SERIAL NUMBER LOCATION ..............................................................................................87 CARBURETOR MODIFICATION FOR HIGH ALTITUDE OPERATION.......................88 EMISSION CONTROL SYSTEM INFORMATION.............................................................89 AIR INDEX................................................
31Z236200.book 7 ページ 2020年2月20日 木曜日 午後1時8分 GENERATOR SAFETY IMPORTANT SAFETY INFORMATION Honda generators are designed for use with electrical equipment that has suitable power requirements. Other uses can result in injury to the operator or damage to the generator and other property. Most injuries or property damage can be prevented if you follow all instructions in this manual and on the generator. The most common hazards are discussed below, along with the best way to protect yourself and others.
31Z236200.book 8 ページ 2020年2月20日 木曜日 午後1時8分 GENERATOR SAFETY Carbon Monoxide Hazards A generator's exhaust contains toxic carbon monoxide, which you cannot see or smell. Breathing carbon monoxide can KILL YOU IN MINUTES. To avoid carbon monoxide poisoning, follow these instructions when operating a generator: • Only run a generator OUTSIDE, far away from windows, doors, and vents with engine exhaust directed away from occupied structures.
31Z236200.book 9 ページ 2020年2月20日 木曜日 午後1時8分 GENERATOR SAFETY Electric Shock Hazards The generator produces enough electric power to cause a serious shock or electrocution if misused. • Do not use in wet conditions. Keep the generator dry. – Do not use in the rain or snow. – Do not use near pool or a sprinkler system. – Do not use when your hands are wet. • If the generator is stored outdoors, unprotected from the weather, check all of the electrical components on the control panel before each use.
31Z236200.book 10 ページ 2020年2月20日 木曜日 午後1時8分 GENERATOR SAFETY Refuel With Care Gasoline is highly flammable, and gasoline vapor can explode. • Do not refuel during operation. • Allow the engine to cool if it has been in operation. • Refuel only outdoors in a well-ventilated area and on a level surface. • Never smoke near gasoline, and keep other flames and sparks away. • Do not overfill the fuel tank. • Make sure that any spilled fuel has been wiped up and cleaned before starting the engine.
31Z236200.book 11 ページ 2020年2月20日 木曜日 午後1時8分 GENERATOR SAFETY SAFETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda generator dealer for a replacement.
31Z236200.book 12 ページ 2020年2月20日 木曜日 午後1時8分 ASSEMBLY SAFETY The Importance of Proper Assembly Proper assembly is essential to operator safety and the reliability of the machine. Improper assembly can cause an unsafe condition. Failure to properly follow assembly procedures can lead to serious injury or death. Follow the procedures and precautions in this owner’s manual carefully. We cannot warn you of every conceivable hazard that can arise in performing this assembly.
31Z236200.book 13 ページ 2020年2月20日 木曜日 午後1時8分 ASSEMBLY ASSEMBLY Unpacking 1. Remove the generator and loose parts box from the carton. 2. Compare the loose parts with the inventory list below. Tools Required: 12 mm wrench (2), pliers Loose Parts (Wheel kit and handle) Do not add fuel or oil before tipping the generator. Oil or fuel may damage the engine or your property. Check all loose parts against the following list.
31Z236200.book 14 ページ 2020年2月20日 木曜日 午後1時8分 ASSEMBLY Handle Installation 1. Install the handle holder assembly on the generator upper frame using the 8×18 mm flange bolts. 2. Install the handle assembly on the generator upper frame pipe using the 8×16 mm flange bolts, handle bush A, handle bush B, and handle lower bracket. Torque: 19.5 lbf·ft (26.5 N·m, 2.
31Z236200.book 15 ページ 2020年2月20日 木曜日 午後1時8分 ASSEMBLY Wheel Kit Installation 1. Install the two stands on the under frame using four 8×16 mm flange bolts. 2. Install the two wheels on the axle shaft using the plain washers and split pins. After installing the split pins, bend the pins to ensure that the wheels are secured to the axle. 3. Install the axle assembly on the generator using four 8×16 mm flange bolts and 8 mm flange nuts. Torque: 19.5 lbf·ft (26.5 N·m, 2.
31Z236200.book 16 ページ 2020年2月20日 木曜日 午後1時8分 ASSEMBLY Battery WARNING: Battery posts, terminals, and related accessories contain lead and lead compounds. Wash your hands after handling. The battery is disconnected for shipment. 1. Remove the cover (see page 73). 2. Connect the battery positive (+) cable to the battery positive (+) terminal first, and tighten the bolt securely. 3. Slide the battery boot over the positive (+) cable and terminal. 4.
31Z236200.book 17 ページ 2020年2月20日 木曜日 午後1時8分 INITIAL USE INSTRUCTIONS ENGINE OIL The generator is shipped WITHOUT OIL in the engine. 1. Place the generator on a level surface. 2. Remove the oil filler cap/dipstick by turning it counterclockwise. 3. Add enough oil to bring the oil level to the upper limit mark on the oil dipstick. SAE 10W-30 API service category SJ or later (or equivalent) is recommended for general use; for additional recommendations (see page 18). Maximum oil capacity: 1.2 US qt (1.
31Z236200.book 18 ページ 2020年2月20日 木曜日 午後1時8分 INITIAL USE INSTRUCTIONS ENGINE OIL RECOMMENDATIONS Oil is a major factor affecting performance and service life. Use 4-stroke automotive detergent oil. SAE 10W–30 is recommended for general use. Other viscosities shown in the chart may be used when the average temperature in your area is within the recommended range. AMBIENT TEMPERATURE Read the instructions on the oil container before use.
31Z236200.book 19 ページ 2020年2月20日 木曜日 午後1時8分 INITIAL USE INSTRUCTIONS FUEL Add fuel to the generator in a well-ventilated area. Fuel only outdoors. Keep gasoline away from appliance, such as pilot lights, barbecues, electric appliances, power tools, etc. Spilled fuel is not only a fire hazard, it causes environmental damage. Fuel carefully to avoid spilling fuel. Wipe up spills immediately. Do not fill the fuel tank above the upper level mark (red) on the fuel strainer.
31Z236200.book 20 ページ 2020年2月20日 木曜日 午後1時8分 INITIAL USE INSTRUCTIONS 1. Remove the fuel tank cap. 2. Fuel carefully to avoid spilling fuel. Do not fill the fuel tank above the upper level mark (red) on the fuel strainer. 3. After refueling, reinstall the fuel tank cap securely. UPPER LEVEL MARK (RED) FUEL TANK CAP FUEL GAUGE FUEL STRAINER EMPTY FULL UPPER LEVEL MARK (RED) Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel tank.
31Z236200.book 21 ページ 2020年2月20日 木曜日 午後1時8分 INITIAL USE INSTRUCTIONS FUEL RECOMMENDATIONS This engine is certified to operate on regular unleaded gasoline with a pump octane rating of 86 or higher. Never use gasoline that is stale, contaminated, or mixed with oil. Avoid getting dirt or water in the fuel tank. You may use regular unleaded gasoline containing no more than 10% ethanol (E10) or 5% methanol by volume. In addition, methanol must contain cosolvents and corrosion inhibitors.
31Z236200.book 22 ページ 2020年2月20日 木曜日 午後1時8分 CONTROLS & FEATURES COMPONENT & CONTROL LOCATIONS Use the illustrations on these pages to locate and identify the most frequently used controls.
31Z236200.
31Z236200.book 24 ページ 2020年2月20日 木曜日 午後1時8分 CONTROLS & FEATURES CONTROLS Engine Switch The engine switch controls the ignition system, and it operates the electric starter. ON START OFF OFF – Stops the engine. The engine switch key can be removed/inserted. ON – Running position, and for starting with the recoil starter. START – Operates the electric starter. Starter Grip Used when the battery voltage is too low to turn the starter motor.
31Z236200.book 25 ページ 2020年2月20日 木曜日 午後1時8分 CONTROLS & FEATURES Fuel Valve Lever The fuel valve lever is located between the fuel tank and carburetor. ON The fuel valve must be in the ON position for the engine to run. OFF After stopping the engine, turn the fuel valve to the OFF position.
31Z236200.book 26 ページ 2020年2月20日 木曜日 午後1時8分 CONTROLS & FEATURES CO-MINDER (CO Shut-off System) CO-MINDER is a system that automatically stops the engine before the surrounding carbon monoxide concentration exceeds a certain level. If the CO-MINDER detects a high carbon monoxide concentration, the engine will stop and the CO ALARM indicator will flash for about five minutes.
31Z236200.book 27 ページ 2020年2月20日 木曜日 午後1時8分 CONTROLS & FEATURES RESTARTING THE ENGINE When the engine is stopped automatically by CO-MINDER, press the COMINDER reset button to restart the engine. If the engine is restarted without pressing the CO-MINDER reset button, the engine will automatically stop immediately after restarting and the CO ALARM indicator will flash for approximately five minutes. Resetting the CO-MINDER is possible only after the CO ALARM indicator is turned off.
31Z236200.book 28 ページ 2020年2月20日 木曜日 午後1時8分 CONTROLS & FEATURES Voltage Selector Switch The voltage selector switch switches generator output to produce “120V ONLY” or “120V/240V.” If a 240V appliance is connected to the 4-prong receptacle, the switch must be in the “120V/240V” position. If only a 120V appliance is being connected to any of the 120V 3-prong receptacles, select the “120V ONLY” position. Select the voltage before starting the engine.
Z236200.book 29 ページ 2020年2月20日 木曜日 午後1時8分 CONTROLS & FEATURES Auto Throttle® System The Auto Throttle® system automatically reduces engine speed when all loads are turned off or disconnected. When appliances are turned on or reconnected, the engine returns to the rated speed. SWITCH POSITION ON - Recommended to minimize fuel consumption and further reduce noise levels when no load is applied to the generator. OFF - The Auto Throttle system does not operate.
31Z236200.book 30 ページ 2020年2月20日 木曜日 午後1時8分 CONTROLS & FEATURES AC Circuit Protectors The AC circuit protectors will automatically switch OFF if there is a short circuit or a significant overload of the generator at each receptacle. If an AC circuit protector switches OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the AC circuit protector ON.
31Z236200.book 31 ページ 2020年2月20日 木曜日 午後1時8分 CONTROLS & FEATURES Ground Fault Circuit Interrupter (GFCI) Receptacle Each 120 V 20 A duplex receptacle is protected by a Ground Fault Circuit Interrupter (GFCI) for protection against the shock hazard of ground-fault currents.
31Z236200.book 32 ページ 2020年2月20日 木曜日 午後1時8分 CONTROLS & FEATURES DC Terminals The DC terminals may ONLY be used for charging 12-volt automotive type batteries. The terminals are colored red to identify the positive (+) terminal and black to identify the negative (–) terminal. The battery must be connected to the generator DC terminals with the proper polarity (battery positive to generator red terminal and battery negative to the generator black terminal).
31Z236200.book 33 ページ 2020年2月20日 木曜日 午後1時8分 CONTROLS & FEATURES Folding Handle The foldable handle is intended for ease of transportation and should be folded when the generator is stationary. Do not rest objects on the extended handle. To extend the handle, lift handle upward. Lock lever will lock and secure the handle into place. To fold the handle, 1. Press handle lock lever downward. 2. Lower the handle.
31Z236200.book 34 ページ 2020年2月20日 木曜日 午後1時8分 CONTROLS & FEATURES FEATURES Oil Alert® System The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert system will automatically stop the engine (the engine switch will remain in the ON position). If the engine stops and will not restart, check the engine oil level (see page 40) before troubleshooting in other areas.
31Z236200.book 35 ページ 2020年2月20日 木曜日 午後1時8分 CONTROLS & FEATURES Auto Choke and Throttle Control System The ECM (Engine Control Module) controls the choke valve and throttle automatically. When starting and warming up the engine, you do not need to operate the choke lever unless the engine is hard to start using the normal starting procedure. ECM MANUAL CHOKE LEVER iAVR (Intelligent Auto Voltage Regulator) This generator is equipped with an intelligent, automatic voltage regulator.
31Z236200.book 36 ページ 2020年2月20日 木曜日 午後1時8分 CONTROLS & FEATURES Fuel Gauge The fuel gauge is a mechanical device that measures the fuel level in the tank. The red indicator in the window will reference the level in relation to full or empty. To provide increased operating time, start with a full tank before beginning operation. Check the fuel level with the generator on a level surface. Always refuel with the engine OFF and cool.
31Z236200.book 37 ページ 2020年2月20日 木曜日 午後1時8分 CONTROLS & FEATURES Bluetooth® Function The generator is connected to a smartphone via a Bluetooth® connection. • The range between your Bluetooth® enabled smartphone and the generator can be maximized when there is a clear, obstruction free, line-of-sight between devices. The connection distance is also affected by the type of smartphone used and the surrounding environment, structures, and electronic interference.
31Z236200.book 38 ページ 2020年2月20日 木曜日 午後1時8分 BEFORE OPERATION ARE YOU READY TO GET STARTED? Your safety is your responsibility. A little time spent in preparation will significantly reduce your risk of injury. Knowledge Read and understand this manual. Know what the controls do and how to operate them. Familiarize yourself with the generator and its operation before you begin using it. Know how to quickly shut off the generator in case of an emergency.
31Z236200.book 39 ページ 2020年2月20日 木曜日 午後1時8分 BEFORE OPERATION Before beginning your pre-operation checks, be sure the generator is on a level surface and the engine switch is in the OFF position. Generators with standard equipment transport wheels must not be operated with the wheels and/or stands removed or else the generator may not operate correctly and can become damaged. Check the Engine • Before each use, look around and underneath the engine for signs of oil or gasoline leaks.
31Z236200.book 40 ページ 2020年2月20日 木曜日 午後1時8分 BEFORE OPERATION ENGINE OIL LEVEL CHECK Check the engine oil level with the engine stopped and in a level position. 1. Remove the oil filler cap/dipstick and wipe it clean. 2. Insert and remove the dipstick without screwing it into the oil filler neck. Check the oil level shown on the dipstick. 3. If the oil level is low, fill with the recommended oil (see page 18) to the upper limit on the oil filler cap/dipstick. 4.
31Z236200.book 41 ページ 2020年2月20日 木曜日 午後1時8分 BEFORE OPERATION AIR FILTER CHECK 1. Unsnap the air cleaner cover clips and open the air cleaner cover. 2. Free the hooks from the setting pins on the air cleaner case and remove the air cleaner cover to the right side of the frame pipe, taking care not to damage the air cleaner cover. 3. Remove the air cleaner element from the air cleaner case. 4. Check the air cleaner element to be sure it is clean and in good condition.
31Z236200.book 42 ページ 2020年2月20日 木曜日 午後1時8分 BEFORE OPERATION 6. Set the hooks of the air cleaner cover to the setting pins securely, and then push the air cleaner cover to lock the clips. Be sure that the cover is set securely. There must be no clearance between the air cleaner cover and air cleaner case. Operating the engine without the air filters, or with a damaged air filters, will allow dirt to enter the engine, causing rapid engine wear.
31Z236200.book 43 ページ 2020年2月20日 木曜日 午後1時8分 BEFORE OPERATION SAFE OPERATING PRECAUTIONS Before operating the generator, review chapters "GENERATOR SAFETY" (see page 7). For your safety, do not operate the generator in an enclosed, or partly enclosed area such as a garage (even if the door is open) or near structures or vehicles. Your generator's exhaust contains poisonous carbon monoxide gas that can collect rapidly in such areas, structures, vehicles, trailers, or boats.
31Z236200.book 44 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION STARTING THE ENGINE To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from building or trailer walls, vehicles, trailers, boats, and other equipment during operation. Do not place flammable objects close to the engine. • Operating this generator less than 3 feet (1 meter) from a building, obstruction, or when it is in an enclosure, a storage or security compartment/bay, can cause overheating and damage the generator.
31Z236200.book 45 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION 1. Make sure that all appliances are disconnected from the AC receptacle. AC CIRCUIT BREAKER 2. Make sure that the AC circuit breaker is in the OFF position. ON OFF 3. Turn the fuel valve lever to the ON position.
31Z236200.book 46 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION 4. Make sure the Auto Throttle switch is in the OFF position, or more time will be required for warm up. AUTO THROTTLE SWITCH OFF 5. Start the engine. • Using the electric starter: Turn the engine switch to the START position, and hold it there until the engine starts. When the engine starts, release the key, allowing the switch to return to the ON position.
31Z236200.book 47 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION • Using the recoil starter: ON a. Turn the engine switch to the ON position. ENGINE SWITCH b. Pull the starter grip lightly until you feel resistance; then pull briskly in the direction of the arrow as shown. • Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter. • Do not let the starter rope rub against the generator body, or the rope will wear out prematurely.
31Z236200.book 48 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION STOPPING THE ENGINE To stop the engine in an emergency, simply turn the engine switch to the OFF position. Under normal conditions, use the following procedure. 1. Turn off or disconnect all appliances that are connected to the generator. 2. Move the AC circuit breaker to the OFF position. AC CIRCUIT BREAKER OFF 3. Turn the engine switch to the OFF position. OFF ENGINE SWITCH 4. Turn the fuel valve lever to the OFF position.
31Z236200.book 49 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION STARTING AND STOPPING THE ENGINE with Bluetooth® ENABLED SMARTPHONE The engine can be started/stopped via a Bluetooth® enabled smartphone using a Bluetooth® application. Refer to the Bluetooth® application to check the connection, operation, and for help pairing a smartphone.
31Z236200.book 50 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION GFCI OPERATION CHECK Always check GFCI operation before using the generator. A faulty GFCI system will not provide proper protection against electric shock as designed. An electric shock can result in serious injury or death. Always perform the GFCI system inspection before using the generator. If the GFCI system fails the test, the generator must be repaired by an authorized Honda servicing dealer before use.
31Z236200.book 51 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION 1. Unplug all tools and appliances from the generator. 2. Start the engine (see page 44). 3. Turn OFF the auto throttle switch (see page 46). 4. Turn the AC circuit breaker to the ON position. When the GFCI is operating normally, the GFCI indicator will continuously light green.
31Z236200.book 52 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION 6. Press the GFCI RESET button: • The green GFCI indicator will light continuously. • If the red GFCI indicator starts to blink continuously, contact an authorized Honda Power Equipment dealer. GFCI INDICATOR GFCI RESET BUTTON When the GFCI RESET button pops out or the green GFCI indicator does not lit during operation: • Unplug all appliances from the GFCI protected receptacle. • Press the GFCI RESET button.
31Z236200.book 53 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION AC OPERATION If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is in the appliance or the rated load capacity of the generator has been exceeded. Substantial overloading may damage the generator. Marginal overloading may shorten the service life of the generator. 1. Turn the voltage selector switch to either position.
31Z236200.book 54 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION 3. Switch ON the AC circuit breaker. 4. Plug in the appliance. Most motorized appliances require more than their rated wattage for startup. AC CIRCUIT PROTECTORS AC CIRCUIT BREAKER ON PLUG 5. Turn on the appliance. Do not exceed the current limit specified for any of the receptacles.
31Z236200.book 55 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION AC Applications Before connecting an appliance or power cord to the generator: • Make sure that it is in good working order. A faulty appliance or power cord can create a potential for electrical shock. • If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is the appliance or the rated load capacity of the generator has been exceeded.
31Z236200.book 56 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION AC Receptacle Selection The control panel, shown below, has a voltage selector switch and four receptacles. Receptacle 4, the 240-volt receptacle, has two powered terminals, 4A and 4B.
31Z236200.book 57 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION Voltage Selector Switch The power available to each receptacle depends on the position of the voltage selector switch. Switch Position 120V ONLY Receptacle 120V/240V - Available Power EM5000SX EM6500SX 30A at 120V 30A at 120V 20A at 120V 20A at 120V 20A at 120V 20A at 120V 30A at 120V 30A at 120V None None 18.8A at 120V 22.9A at 120V 18.8A at 120V 20A at 120V 18.8A at 120V 20A at 120V 18.8A at 240V 22.
31Z236200.book 58 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION DC OPERATION The DC receptacle should ONLY be used for charging 12-volt automotive type batteries. The DC charging output is not regulated. Connecting the battery charging cable (optional equipment): 1. Before connecting the battery charging cable (optional equipment) to a battery that is installed in a vehicle, disconnect the vehicle battery ground cable from the negative (–) battery terminal.
31Z236200.book 59 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION 3. Connect the black lead of battery charging cable into the negative (–) DC terminal of the generator. 4. Connect the red lead of the battery charging cable to the positive (+) battery terminal and the black lead to the negative (–) battery terminal. 5. Start the generator. Do not start the vehicle while the battery charging cable is connected and the generator is running. The vehicle or the generator may be damaged.
31Z236200.book 60 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION AUTO THROTTLE® SYSTEM With the switch in the AUTO position, engine speed is automatically reduced when ALL loads are turned OFF or disconnected. When appliances are turned ON or reconnected, the engine returns to rated speed. In the OFF position, the Auto Throttle system does not operate. The Auto Throttle system will not respond to electrical loads of less than 1 ampere or intermittent loads such as a staple gun.
31Z236200.book 61 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION STANDBY POWER Connections to a Building’s Electrical System Connections for standby power to a building’s electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes. Improper connections to a building’s electrical system can allow current from the generator to backfeed into the utility lines.
31Z236200.book 62 ページ 2020年2月20日 木曜日 午後1時8分 OPERATION Special Requirements There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction. • In some areas, generators are required to be registered with local utility companies.
31Z236200.book 63 ページ 2020年2月20日 木曜日 午後1時8分 SERVICING YOUR GENERATOR THE IMPORTANCE OF MAINTENANCE Good maintenance is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. To help you properly care for your generator, the following pages include a maintenance schedule, routine inspection procedures, and simple maintenance procedures using basic hand tools.
31Z236200.book 64 ページ 2020年2月20日 木曜日 午後1時8分 SERVICING YOUR GENERATOR MAINTENANCE SAFETY Some of the most important safety precautions follow. However, we cannot warn you of every conceivable hazard that can arise in performing maintenance. Only you can decide whether or not you should perform a given task. Improper maintenance can cause an unsafe condition. Failure to properly follow maintenance instructions and precautions can cause serious injuries or death.
31Z236200.book 65 ページ 2020年2月20日 木曜日 午後1時8分 SERVICING YOUR GENERATOR MAINTENANCE SCHEDULE Failure to follow this maintenance schedule could result in non-warrantable failures. REGULAR SERVICE PERIOD (3) Perform at every indicated month or operating hour interval, whichever comes first.
31Z236200.book 66 ページ 2020年2月20日 木曜日 午後1時8分 SERVICING YOUR GENERATOR ENGINE OIL CHANGE Drain the oil while the engine is warm to assure rapid and complete draining. 1. Place a suitable container below the engine to catch the used oil, and then remove the oil filler cap/dipstick, 12×15 mm drain plug, and sealing washer. 2. Allow the used oil to drain completely, and then reinstall the 12×15 mm drain plug and a new sealing washer. Tighten the plug securely. Torque: 16.3 lbf·ft (22.1 N·m, 2.25 kgf·m) 3.
31Z236200.book 67 ページ 2020年2月20日 木曜日 午後1時8分 SERVICING YOUR GENERATOR AIR CLEANER SERVICE Foam Air Filter Cleaning A dirty air cleaner element will restrict air flow to the carburetor, reducing engine performance. If you operate the generator in very dusty areas, clean the air cleaner element more frequently than specified in the Maintenance Schedule. 1. Clean the foam air filter in warm soapy water, rinse, and allow to dry thoroughly, or clean in non-flammable solvent and allow to dry. 2.
31Z236200.book 68 ページ 2020年2月20日 木曜日 午後1時8分 SERVICING YOUR GENERATOR SPARK PLUG SERVICE In order to service the spark plug, you will need a spark plug wrench (commercially available). Required spark plug: BPR5ES (NGK) W16EPR-U (DENSO) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. An incorrect spark plug can cause engine damage. If the engine is hot, allow it to cool before servicing the spark plug. 1.
31Z236200.book 69 ページ 2020年2月20日 木曜日 午後1時8分 SERVICING YOUR GENERATOR 4. Measure the spark plug electrode gap with a wire-type feeler gauge. Correct the gap, if necessary, by carefully bending the side electrode. Spark plug gap: 0.028–0.031 in (0.7–0.8 mm) SIDE ELECTRODE 0.028–0.031 in (0.7–0.8 mm) SEALING WASHER 5. Make sure that the spark plug sealing washer is in good condition, and thread the spark plug in by hand to prevent cross-threading. 6.
31Z236200.book 70 ページ 2020年2月20日 木曜日 午後1時8分 SERVICING YOUR GENERATOR SPARK ARRESTER SERVICE The spark arrester must be serviced every 100 hours to keep it functioning as designed. If the engine has been running, the muffler will be very hot. Allow the muffler to cool before servicing the spark arrester. Clean the spark arrester as follows: 1. Remove the two 5 mm screws, and remove the spark arrester. 5 mm SCREWS SPARK ARRESTER 2. Use a brush to remove carbon deposits from the spark arrester screen.
31Z236200.book 71 ページ 2020年2月20日 木曜日 午後1時8分 SERVICING YOUR GENERATOR SEDIMENT CUP CLEANING The sediment cup prevents dirt or water that may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned. Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. • Stop the engine and let it cool before handling fuel. • Keep heat, sparks, and flame away. • Handle fuel only outdoors.
31Z236200.book 72 ページ 2020年2月20日 木曜日 午後1時8分 SERVICING YOUR GENERATOR BATTERY SERVICE Your generator’s engine charging system charges the battery while the engine is running. However, if the generator is only used periodically, the battery must be charged monthly to maintain the battery service life. The battery contains sulfuric acid (electrolyte), which is highly corrosive and poisonous. Getting electrolyte in your eyes or on your skin can cause serious burns.
31Z236200.book 73 ページ 2020年2月20日 木曜日 午後1時8分 SERVICING YOUR GENERATOR The battery gives off explosive hydrogen gas during normal operation. A spark or flame can cause the battery to explode with enough force to kill or seriously hurt you. Wear protective clothing and a face shield, or have a skilled mechanic perform the battery maintenance. Battery Removal WARNING: Battery posts, terminals, and related accessories contain lead and lead compounds. Wash your hands after handling. 1.
31Z236200.book 74 ページ 2020年2月20日 木曜日 午後1時8分 SERVICING YOUR GENERATOR 4. Remove the battery from the battery tray. BATTERY This symbol on the battery means that this product must not be treated as household waste. An improperly disposed of battery can be harmful to the environment and human health. Always confirm local regulations for battery disposal. Battery Charging The battery is rated at 11.2 Ah (ampere-hours). Charging current should equal 10% of the battery’s ampere-hour rating.
31Z236200.book 75 ページ 2020年2月20日 木曜日 午後1時8分 SERVICING YOUR GENERATOR 5. Install the battery holder band. 6. Install the battery cover in the reverse order of removal (see page 73). Never operate the generator without the battery cover in place, as poor engine and generator performance will result.
31Z236200.book 76 ページ 2020年2月20日 木曜日 午後1時8分 SERVICING YOUR GENERATOR FUSE If the fuse is blown, the starter motor won’t operate. In the event of fuse failure, locate the cause of failure and repair it before you continue operation. If the fuse continues to fail, discontinue generator use and consult an authorized Honda Power Equipment dealer. 1. Turn the engine switch to the OFF position and remove the key before checking or replacing the fuse. 2. Remove the fuse holder cover and pull the fuse out.
31Z236200.book 77 ページ 2020年2月20日 木曜日 午後1時8分 STORAGE STORAGE PREPARATION Proper storage preparation is essential for keeping your generator trouble-free and looking good. The following steps will help to keep rust and corrosion from impairing your generator’s function and appearance, and will make the engine easier to start when you use the generator again. Cleaning Wipe the generator with a moist cloth.
31Z236200.book 78 ページ 2020年2月20日 木曜日 午後1時8分 STORAGE Service according to the table below: STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required 1 to 2 months Fill with fresh gasoline and add gasoline stabilizer*. 2 months to 1 year Fill with fresh gasoline and add gasoline stabilizer*. Drain the carburetor float bowl (see page 79). Drain the fuel sediment cup (see page 71). 1 year or more Fill with fresh gasoline and add gasoline stabilizer*.
31Z236200.book 79 ページ 2020年2月20日 木曜日 午後1時8分 STORAGE DRAINING THE FUEL TANK AND CARBURETOR Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. • Stop the engine and let it cool before handling fuel. • Keep heat, sparks, and flame away. • Handle fuel only outdoors. • Keep away from your vehicle. • Wipe up spills immediately. 1. Turn the fuel valve lever to the OFF position. 2.
31Z236200.book 80 ページ 2020年2月20日 木曜日 午後1時8分 STORAGE 4. After all the gasoline has drained into the container, tighten the drain screw securely. 5. Place a suitable gasoline container below the sediment cup, and use a funnel to avoid spilling gasoline. 6. Remove the sediment cup (see page 71), and then turn the fuel valve lever to the ON position. 7. Allow the gasoline to drain completely, and then install the sediment cup and a new O-ring (see page 71).
31Z236200.book 81 ページ 2020年2月20日 木曜日 午後1時8分 STORAGE STORAGE PRECAUTIONS If your generator will be stored with gasoline in the fuel tank and carburetor, it is important to reduce the hazard of gasoline vapor ignition. Select a well ventilated storage area away from any appliance that operates with a flame, such as a furnace, water heater, or clothes dryer. Also avoid any area with a spark-producing electric motor, or where power tools are operated.
31Z236200.book 82 ページ 2020年2月20日 木曜日 午後1時8分 TRANSPORTING An engine that has been running will remain very hot for a period of time. A hot engine and exhaust system can burn you and ignite some material. If the generator has been used, allow it to cool for at least 15 minutes before loading the generator on the transport vehicle. To prevent spillage when transporting, the generator should be secured upright in its normal operating position, with the fuel valve OFF.
31Z236200.book 83 ページ 2020年2月20日 木曜日 午後1時8分 TRANSPORTING To lift the generator Lift the generator by the lifting hanger. Do not try to lift the generator by and other part.
31Z236200.book 84 ページ 2020年2月20日 木曜日 午後1時8分 TAKING CARE OF UNEXPECTED PROBLEMS ENGINE WILL NOT START Possible Cause Fuel valve lever OFF. Engine switch OFF. Out of fuel. Bad fuel; generator stored without treating or draining gasoline, or refueled with bad gasoline. Low oil level caused Oil Alert to stop engine. Spark plug faulty, fouled, or improperly gapped. Spark plug wet with fuel (flooded engine). Fuel strainer restricted, carburetor malfunction, ignition malfunction, valves stuck, etc.
31Z236200.book 85 ページ 2020年2月20日 木曜日 午後1時8分 TAKING CARE OF UNEXPECTED PROBLEMS ENGINE LACKS POWER Possible cause Air filter restricted. Bad fuel; generator stored without treating or draining gasoline, or refueled with bad gasoline. Fuel strainer restricted, carburetor malfunction, ignition malfunction, valves stuck, etc. Correction Clean or replace air filter (see pages 41, 67). Drain fuel tank and carburetor (see page 79). Refuel with fresh gasoline (see page 19).
31Z236200.book 86 ページ 2020年2月20日 木曜日 午後1時8分 TAKING CARE OF UNEXPECTED PROBLEMS NO POWER AT THE DC TERMINALS Possible Cause DC circuit protector OFF. Faulty generator. Correction Turn DC circuit protector ON (see page 32). Take the generator to an authorized Honda Power Equipment dealer, or refer to the shop manual. ENGINE AUTOMATICALLY STOP AND THE CO ALARM INDICATOR FLASHING Possible Cause CO concentration around the generator is high.
31Z236200.book 87 ページ 2020年2月20日 木曜日 午後1時8分 TECHNICAL INFORMATION SERIAL NUMBER LOCATION FRAME SERIAL NUMBER ENGINE SERIAL NUMBER QR CODE Record the frame serial number and date purchased in the spaces below. You will need this information when ordering parts and when making technical or warranty inquiries. Engine serial number: Frame serial number: Date purchased: Entering the frame serial number of the generator is required during the first Bluetooth® connection.
31Z236200.book 88 ページ 2020年2月20日 木曜日 午後1時8分 TECHNICAL INFORMATION CARBURETOR MODIFICATION FOR HIGH ALTITUDE OPERATION At high altitude, the standard carburetor air-fuel mixture will be too rich. Performance will decrease, and fuel consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting. Operation at an altitude that differs from that at which this engine was certified, for extended periods of time, may increase emissions.
31Z236200.book 89 ページ 2020年2月20日 木曜日 午後1時8分 TECHNICAL INFORMATION EMISSION CONTROL SYSTEM INFORMATION Source of Emissions The combustion process produces carbon monoxide, oxides of nitrogen, and hydrocarbons. Control of hydrocarbons and oxides of nitrogen is very important because, under certain conditions, they react to form photochemical smog when subjected to sunlight. Carbon monoxide does not react in the same way, but it is toxic.
31Z236200.book 90 ページ 2020年2月20日 木曜日 午後1時8分 TECHNICAL INFORMATION Problems That May Affect Emissions If you are aware of any of the following symptoms, have your engine inspected and repaired by your authorized Honda servicing dealer. • Hard starting or stalling after starting. • Rough idle. • Misfiring or backfiring under load. • Afterburning (backfiring). • Black exhaust smoke or high fuel consumption.
31Z236200.book 91 ページ 2020年2月20日 木曜日 午後1時8分 TECHNICAL INFORMATION AIR INDEX (Models sold in California) An Air Index Information label is applied to engines certified to an emission durability time period in accordance with the requirements of the California Air Resources Board. The bar graph is intended to provide you, our customer, the ability to compare the emissions performance of available engines. The lower the Air Index, the less pollution.
31Z236200.book 92 ページ 2020年2月20日 木曜日 午後1時8分 TECHNICAL INFORMATION SPECIFICATION Dimensions Model EM5000SXK3 EM6500SXK2 Type AG type Description code Length [Handle in up position] EBMC EBJC 28.7 in (728 mm) [41.1 in (1,043 mm)] 29.0 in (736 mm) [41.4 in (1,051 mm)] Width 27.8 in (706 mm) Height [Handle in up position] 30.4 in (771 mm) [28.3 in (719 mm)] Dry mass [weight] 226.4 lbs (102.7 kg) 231.7 lbs (105.
31Z236200.book 93 ページ 2020年2月20日 木曜日 午後1時8分 TECHNICAL INFORMATION Tuneup Specifications ITEM SPECIFICATION MAINTENANCE Spark plug gap 0.028–0.031 in (0.7–0.8 mm) Refer to page 68 Valve clearance (cold) IN: 0.15±0.02 mm EX: 0.20±0.02 mm See your authorized Honda dealer. Other specifications No other adjustments needed. Specifications may vary according to the types, and are subject to change without notice.
31Z236200.
Br W/R Br DC. W EARTH Bl/R Br Br W R + MW(V) MW(N2) DC DIODE FW EX W MW MW(U) MW(N1) Bu Br Bu Bu EARTH Bu Bu FRAME BLOCK G R W CT Y R R OIL LEVEL SW Bu D-CD1 S-PLUG Bu ECU D-AVR R R Bu MAIN BREAKER Bu BATTERY FUSE 20A Bl/W STARTER M W R W BREATHER HEATER (YOP) ENG BLOCK CHARGE POWER COIL COIL VOLT CHANGE SW Bu R Br Bu 11 Bu W Br 2 Bu Br 10 12 7 9 8 Bu R Bu Br 5 1 3 4 6 Bl R FUSE 0.
31Z236200.book 96 ページ 2020年2月20日 木曜日 午後1時8分 CONSUMER INFORMATION DEALER LOCATOR INFORMATION To find an authorized Honda Servicing Dealer anywhere in the United States, visit our website: http://powerequipment.honda.com/dealer-locator Honda PUBLICATIONS Shop Manual This manual covers complete maintenance and overhaul procedures. It is intended to be used by a skilled technician. Available through your Honda dealer or visit http://powerequipment.honda.
31Z236200.book 97 ページ 2020年2月20日 木曜日 午後1時8分 CONSUMER INFORMATION CUSTOMER SERVICE INFORMATION Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership’s management. The Service Manager or General Manager can help. Almost all problems are solved in this way.
31Z236200.book 98 ページ 2020年2月20日 木曜日 午後1時8分 CONSUMER INFORMATION Distributor’s Limited Warranty This warranty is limited to the following Honda Power Equipment products when distributed by American Honda Motor Co., Inc., Power Equipment Division, 4900 Marconi Drive, Alpharetta, Georgia 30005-8847. The following warranty applies to products purchased at retail or placed in rental service on or after January 1, 2010.
31Z236200.book 99 ページ 2020年2月20日 木曜日 午後1時8分 CONSUMER INFORMATION To Obtain Warranty Service: You must, at your expense, take the Honda Power Equipment product, accessory, replacement part, apparel, or the power equipment on which the accessory or replacement part is installed, and proof of purchase to any Honda Power Equipment dealer in the United States, Puerto Rico, or the U.S. Virgin Islands who is authorized to sell that product, during the dealer’s normal business hours.
31Z236200.book 100 ページ 2020年2月20日 木曜日 午後1時8分 CONSUMER INFORMATION Exclusions: 1.
31Z236200.book 101 ページ 2020年2月20日 木曜日 午後1時8分 CONSUMER INFORMATION Honda Accessories, Replacement Parts, And Apparel This warranty is limited to Honda Power Equipment parts, accessories, and apparel when distributed by American Honda Motor Co., Inc., 4900 Marconi Drive, Alpharetta, Georgia 30005-8847.
31Z236200.book 102 ページ 2020年2月20日 木曜日 午後1時8分 CONSUMER INFORMATION To Obtain Warranty Service: You must, at your expense, take the Honda Power Equipment accessory, replacement part, apparel, or the Honda Power Equipment on which the accessory or replacement part is installed, and proof of purchase to any Honda Power Equipment dealer, distributor, or distributor’s dealer in the United States, Puerto Rico, or the U.S.
31Z236200.book 103 ページ 2020年2月20日 木曜日 午後1時8分 CONSUMER INFORMATION Emission Control System Warranty Your new Honda Power Equipment engine complies with the U.S. EPA, Environment Canada, and State of California (models certified for sale in California only) emission regulations. American Honda Motor Co., Inc. provides the emission warranty coverage for engines in the United States and its territories. Honda Canada Inc.
31Z236200.book 104 ページ 2020年2月20日 木曜日 午後1時8分 CONSUMER INFORMATION OWNER'S WARRANTY RESPONSIBILITY: • As the power equipment engine owner, you are responsible for the performance of the required maintenance listed in your owner's manual. Honda recommends that you retain all receipts covering maintenance on your power equipment engine, but Honda cannot deny warranty coverage solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance.
31Z236200.book 105 ページ 2020年2月20日 木曜日 午後1時8分 CONSUMER INFORMATION YOUR WARRANTY RIGHTS AND OBLIGATIONS Other States, U.S. territories, and Canada: In other areas of the United States and in Canada, your engine must be designed, built, and equipped to meet the U.S. EPA and Environment Canada emission standards for spark-ignited engines at or below 19 kilowatts.
31Z236200.book 106 ページ 2020年2月20日 木曜日 午後1時8分 CONSUMER INFORMATION TO OBTAIN WARRANTY SERVICE: You must, at your own expense, take your Honda Power Equipment engine or the product on which it is installed, along with your sales registration card or other proof of original purchase date, to any Honda Power Equipment dealer who is authorized by Honda to sell and service that Honda product during their normal business hours.
31Z236200.book 107 ページ 2020年2月20日 木曜日 午後1時8分 CONSUMER INFORMATION DISCLAIMER OF CONSEQUENTIAL DAMAGE AND LIMITATION OF IMPLIED WARRANTIES: American Honda Motor Co., Inc. and Honda Canada Inc. disclaim any responsibility for incidental or consequential damages such as loss of time or the use of the power equipment, or any commercial loss due to the failure of the equipment; and any implied warranties are limited to the duration of this written warranty.
31Z236200.book 108 ページ 2020年2月20日 木曜日 午後1時8分 CONSUMER INFORMATION REGISTRATION Please Register Your Generator If your dealer did not collect registration information from you, please take a few minutes and register your purchase with Honda. This allows us to contact you with any important updates regarding your generator. Please note registration is not required to obtain warranty service. You can register your generator by visiting the Honda Power Equipment website, http://powerequipment.honda.
31Z236200.book 109 ページ 2020年2月20日 木曜日 午後1時8分 OPTIONAL PARTS REMOTE CONTROL KIT 1. Remove the plug from the 4-pin connector. 2. Connect the remote control cable to the back of the control panel and remote control box. 4-PIN CONNECTOR REMOTE CONTROL CABLE REMOTE CONTROL BOX • When the remote control is not being used, replace it with the plug on the connector.
31Z236200.book 110 ページ 2020年2月20日 木曜日 午後1時8分 OPTIONAL PARTS Remote Control Box ENGINE START BUTTON PILOT LAMP MAIN SWITCH ON OFF STARTING THE ENGINE WITH REMOTE CONTROL 1. Turn the fuel valve on the generator to the ON position. 2. Turn the Auto Throttle switch on the generator to the OFF position. 3. Turn the engine switch on the generator to the ON position. 4. Turn the MAIN switch of the remote control to the ON position. 5. Press the ENGINE START button for three seconds.
31Z236200.book 111 ページ 2020年2月20日 木曜日 午後1時8分 OPTIONAL PARTS HANGER KIT 1. Position the hanger at the generator’s balance point as shown below. 2. Fit the end tabs of the hanger through the bracket slots, and bolt the brackets to the hanger and tighten securely. Torque: 19.5 lbf·ft (26.5 N·m, 2.
31Z236200.book 112 ページ 2020年2月20日 木曜日 午後1時8分 REFERENCE INFORMATION “QR Code” is registered trademark of DENSO WAVE INCORPORATED. The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc., and any use of such marks by Honda Motor Co., Ltd., is under license. Other trademarks and trade names are those of their respective owners. FCC Compliance Statement This device complies with part 15 of the FCC Rules.
31Z236200.book 113 ページ 2020年2月20日 木曜日 午後1時8分 INDEX A AC Appliance and Power Cord........................................................................................ 39 AC Applications .................................................................................................................... 55 AC Circuit Breaker................................................................................................................ 29 AC Circuit Protectors ............................................
31Z236200.book 114 ページ 2020年2月20日 木曜日 午後1時8分 INDEX D DC Circuit Protector ............................................................................................................ 32 DC OPERATION ..................................................................................................................... 58 DC Terminals ......................................................................................................................... 32 DEALER LOCATOR INFORMATION .......................
31Z236200.book 115 ページ 2020年2月20日 木曜日 午後1時8分 INDEX G GENERATOR SAFETY ............................................................................................................. 7 GFCI OPERATION CHECK................................................................................................... 50 Ground Fault Circuit Interrupter (GFCI) Receptacle ................................................ 31 Ground Terminal.....................................................................................
31Z236200.book 116 ページ 2020年2月20日 木曜日 午後1時8分 INDEX Q QUICK REFERENCE INFORMATION ...................................................inside back cover R REFERENCE INFORMATION ........................................................................................... 112 Refuel With Care................................................................................................................... 10 REGISTRATION ..........................................................................................
31Z236200.book 117 ページ 2020年2月20日 木曜日 午後1時8分 INDEX U Unpacking .............................................................................................................................. 13 V Vehicles and Transportation Hazards........................................................................... 10 Voltage Selector Switch.............................................................................................. 28, 57 W Wheel Kit Installation..................................................
31Z236200.
31Z236200.
31Z236200.
31Z236200.book 121 ページ 2020年2月20日 木曜日 午後1時8分 QUICK REFERENCE INFORMATION Fuel Type Engine Oil Type Spark Plug Type Maintenance Electrode Gap Before each use First 20 hours Subsequent Regular unleaded gasoline with an ethanol content of no more than 10% and a pump octane rating of 86 or higher (see page 21) SAE 10W-30, API SJ or later (or equivalent), for general use (see page 18) Maximum oil capacity: 1.2 US qt (1.1 L) BPR5ES (NGK) W16EPR-U (DENSO) 0.028–0.031 in (0.7–0.
Owner’s Manual GENERATOR EM5000SX/EM6500SX See page 12 for instructions on assembling your generator. See page 17 for Initial Use Instructions. 31Z23620 00X31-Z23-6200 PANTONE 186C K 背幅3mm AH 英 N Hi FM Printed in China C 2020 Honda Motor Co., Ltd.