RESTARTING THE ENGINE
When the engine is stopped automatically by CO-MINDER, press the CO-
MINDER reset button to restart the engine.
If the engine is restarted without pressing the CO-MINDER reset button, the
engine will automatically stop immediately after restarting and the CO ALARM
indicator will flash for approximately five minutes.
Resetting the CO-MINDER is possible only after the CO ALARM indicator is
turned off.
CO-MINDER MALFUNCTION DETECTION
If the CO-MINDER detects a system malfunction, the engine will stop
automatically and the FAULT/CO SENSOR LIFE indicator will flash for
approximately five minutes. Press the CO-MINDER reset button to turn off the
FAULT/CO SENSOR LIFE indicator. If the engine will not remain running after
attempting to restart it and the FAULT/CO SENSOR LIFE indicator comes on
again, there may be a system malfunction. If this occurs, do not attempt to
restart the generator more than two times. If the CO-MINDER system is
malfunctioning, it cannot warn you of potential high concentrations of carbon
monoxide. Move the generator to a well-ventilated location and consult an
authorized Honda Power Equipment dealer.
CO SENSOR LIFE
If the FAULT/CO SENSOR LIFE indicator flashes when operating the generator,
the CO-MINDER may be reaching the end of its useful lifespan and will
eventually need replacement.
If the indicator flashes once every four seconds, this means there is
approximately six months to one year of life left in the CO-MINDER.
If the indicator flashes once every two seconds, this means there is
approximately six months of life or less left in the CO-MINDER.
The FAULT/CO SENSOR LIFE indicator indicates the estimated life left in the CO-
MINDER.
The generator stopping period and storage period are also included in the useful
lifespan of the CO-MINDER.
Contact an authorized Honda Power Equipment dealer for CO-MINDER
replacement.