TAKING CARE OF UNEXPECTED PROBLEMS
85
ENGINE LACKS POWER
NO POWER AT THE AC RECEPTACLES
Possible cause Correction
Air filter restricted. Clean or replace air filter
(see pages 41, 67).
Bad fuel; generator stored without
treating or draining gasoline, or
refueled with bad gasoline.
Drain fuel tank and carburetor
(see page 79).
Refuel with fresh gasoline
(see page 19).
Fuel strainer restricted, carburetor
malfunction, ignition malfunction,
valves stuck, etc.
Take the generator to an authorized
Honda Power Equipment dealer, or
refer to the shop manual.
Possible Cause Correction
AC circuit breaker left in the OFF
position after starting.
Switch AC circuit breaker ON (see
page 53).
GFCI system activated. • GFCI receptacle
(120 V 20 A duplex receptacle): Test
GFCI and press the GFCI RESET
button (see page 50).
• Replace or repair power tool or
appliance.
AC circuit protector tripped. Check AC load and reset AC circuit
protector (see page 30).
Faulty power tool or appliance. Replace or repair power tool or
appliance.
Stop and restart the engine.
Internal circuit overheated. Stop the engine. Reduce the electrical
load. Wait a few minutes for the
internal circuit to cool down. Restart
the engine.
Faulty generator. Take the generator to an authorized
Honda Power Equipment dealer, or
refer to the shop manual.