Product Manual

16
OPERATION
SUCTION HOSE INSTALLATION
HOSE CONNECTOR
SUCTION HOSE
HOSE COUPLER
STRAINER
HOSE CLAMP
HOSE
HOSE CLAMP RING
HOSE CLAMP
HOSE CONNECTOR
SEALING WASHER
HOSE CLAMP
To SUCTION PORT
Use the hose, hose connector and hose clamp provided with the pump.
The suction hose must be reinforced with a noncollapsible wall or
braided wire construction to prevent suction hose collapse.
The suction hose should be no longer than necessary. Pump
performance is best when the pump is near the water level, and the
hoses are short.
Never use a suction hose with an inside diameter less than 25 mm
(1 inch).
Use a hose clamp to securely fasten the hose connector to the suction
hose in order to prevent air leakage and loss of suction. Verify that the
hose connector sealing washer is in good condition.
Install the strainer (provided with the pump) on the other end of the
suction hose, and secure it with a hose clamp. The strainer will help to
prevent the pump from becoming clogged or damaged by debris.
Securely tighten the hose connector on the pump suction port.
09/03/16 18:59:03 31YE9603_017