USER INFORMATION SHEET
CATEGORY II : Intermediate risks
N° 102
EN
Version 06
PROTECTION GLOVES AGAINST RISKS :
MECHANICAL
THIS ITEM HAS BEEN DESIGNED IN
COMPLIANCE WITH THE STANDARDS:
EN 420:2010 : Protection Gloves General Requirements
EN 388:2003 : Gloves for the protection against mechanical risks
The CE marking on this glove means that it meets the essential requirements provided for in the European Directive EEC 89/686
concerning Individual Protection Equipment (PPE): Harmlessness - Comfort - Dexterity - Sturdiness
This IPE model is subjected to a CE test
carried out by a certified body:
CTC N° 0075- Parc Scientifique Tony Garnier
4, rue Hermann Frenkel - 69367 LYON Cedex
- FRANCE
THE FOLLOWING MARKING APPEARS ON THE BACK OF EACH GLOVE
Item reference and
size
CE Logo + symbol
RESULTS
Marking for compliance with the European directive 89/686 (minimum height 5mm)
REFERENCE TO
STANDARDS EXPRESSED
Mechanical Performances:
Abrasion resistance
(cycles)Cut resistance
(index)
Tear resistance (Newton)
Perforation resistance
(Newton)
0 : level <1
X : not tested
MECHANICAL RISKS EN 388 : 2003 :
XXXX
(abcd)
Performance level chart
Test
1
2
3
4
5
a) Abrasion resistance
100
500
2000
8000
/
b) Cut resistance (
index
)
1,2
2,5
5,0
10,0
20,0
c) Tear resistance (Newton)
10
25
50
75
/
d) Perforation resistance (
Newton)
20
60
100
150
/
DO NOT USE:
In hot atmospheres with effects comparable to those of a temperature higher than or equal to 50 C.
With infrared rays, flames and major ejections of materials in fusion.
In cold atmospheres with effects comparable to those of a temperature below than or equal to -5 C.
We would like to draw the users' attention to the fact that this glove, with ultra pulling re
sistance, must not be used when there is a risk
of entanglement with machines in motion.
In the case where the glove is only coated on part of its surface (side or palm), the protection levels are only guaranteed on this part.
In addition, some of these gloves are destined for use not requiring total wrist protection (lengths below the minimum requirements of
the EN 420 standard).
This PPE provides no protection of the metacarpal bones.
It is recommended to ensure that the item is clean and in good condition before using.
This IPE only offers protection against the risks indicated in this technical data sheet and only for the levels indicated. Any risk not
included in this technical data sheet is not covered.
The analysis of residual risks at the workstation and the choice of the suitable IPE (new or cleaned) is the responsibility of the user
(directive 89/656/EEC).
ANY MODIFICATION OF THIS IPE SHALL LEAD TO THE LOSS OF THE GUARANTEE OF ITS PROTECTION LEVELS.
CLEANING
Contact the glove division of
HONEYWELL SAFETY PRODUCTS
or your approved seller.
In the event of cleaning, the level
s
of performances cannot be guaranteed any more.
STORAGE Keep this item away from humidity / light.
102-V06-AN / 08/01/2014

Summary of content (1 pages)