Data Sheet
LINEAR MAGNETIC FIELD SENSORS
2
HMC1001/1002 SPECIFICATIONS
Characteristics Conditions* Min Typ Max Unit
Bridge Supply Vbridge referenced to GND 5 12 Volts
Bridge Resistance Bridge current = 10mA 600 850 1200 ohm
Operating Temperature (4) -55 150 °C
Storage Temperature (4) Unbiased -55 175 °C
Field Range (4) Full scale (FS), total applied field -2 +2 gauss
Linearity Error (4) Best fit straight line ±1 gauss 0.1 0.5 %FS
±2 gauss 1 2
Hysteresis Error (4) 3 sweeps across ±2 gauss 0.05 0.10 %FS
Repeatability Error (4) 3 sweeps across ±2 gauss 0.05 0.10 %FS
S/R Repeatability (1) 10
S/R Repeatability (2) Output variation after alternate S/R pulses 2 100 µV
Bridge Offset Offset = (OUT+) – (OUT-), Field=0 gauss -60 -15 30 mV
after Set pulse, Vbridge=8V
Sensitivity S/R Current = 3A 2.5 3.2 4.0 mV/V/gauss
Noise Density (4) Noise at 1 Hz, Vbridge=5V 29 nV/ Hz
Resolution (4) Bandwidth=10Hz, Vbridge=5V 27 µgauss
Bandwidth (4) Magnetic signal (lower limit = DC) 5 MHz
OFFSET Strap Measured from OFFSET+ to OFFSET- 2.5 3.5 ohm
OFFSET Strap Ω Tempco (4) T
A = -40 to 125° C 0.39 %/° C
OFFSET Field (4) Field applied in sensitive direction 46 51 56 mA/gauss
Set/Reset Strap Measured from S/R+ to S/R- 1.5 1.8 ohm
Set/Reset Current (2) (3) (4) 2 µs current pulse, 1% duty cycle 3.0 3.2 5 Amp
Set/Reset Ω Tempco (4) T
A = -40 to 125° C 0.37 %/° C
Disturbing Field (4) Sensitivity starts to degrade. 3 gauss
Use S/R pulse to restore sensitivity.
Sensitivity Tempco (4) T
A = -40 to 125° C Vbridge=8V -0.32 -0.3 -0.28 %/° C
Ibridge=5mA -0.06
Bridge Offset Tempco (4) T
A = -40 to 125° C no Set/Reset ±0.03 %/° C
Vbridge=5V with Set/Reset ±0.001
Resistance Tempco (4) T
A = -40 to 125° C 0.25 %/° C
Cross-Axis Effect (4) Cross field=1gauss no Set/Reset ±3 %FS
(see AN-205) with Set/Reset +0.5
Max. Exposed Field (4) No perming effect on zero reading 10000 gauss
Weight HMC1001 0.14 gram
HMC1002 0.53
(1) VBridge = 4.3V, IS/R = 3.2A, VOUT = VSET – VRESET
(2) If VBridge = 8.0V, IS/R = 2.0A, lower S/R current leads to greater output variation.
(3) Effective current from power supply is less than 1mA.
(4) Not tested in production, guaranteed by characterization.
(*) Tested at 25° C except otherwise stated.
Units: 1 gauss (g) = 1 Oersted (in air), = 79.58 A/m, 1G = 10E-4 Tesla, 1G = 10E5 gamma.