Instructions
7 - 5
Select Require to prevent the scanner from decoding a single āDā Codabar 
symbol without its companion. This selection has no effect on Codabar 
symbols without Stop/Start D characters.
Concatenation Timeout
When searching for bar codes during concatenation, you may wish to 
set a delay used to find the next bar code. Set the length (in millisec-
onds) for this delay by scanning the following bar code, then setting the 
timeout (from 1-65535 milliseconds) by scanning digits from the 
Programming Chart, then scanning Save. 
Default = 750.
Codabar Redundancy
If you are encountering errors when reading Codabar bar codes, you may 
want to adjust the redundancy count.  Redundancy adjusts the number of 
times a bar code is decoded before transmission, which may reduce the 
number of errors. Note that the higher the redundancy count, the longer it 
will take to decode the bar code. To adjust the redundancy, scan the follow-
ing Codabar Redundancy bar code, then scan a redundancy count 
between 0 and 10 on the Programming Chart inside the back cover of this 
manual. Then scan the Save bar code. 
Default = 0.
On
* Off
Require
Concatenation Timeout
Codabar Redundancy