Data Sheet
Hall-Effect Rotary Position Sensors
Honeywell Sensing and Control 3
Figure 1. Mounting Dimensions (For Reference Only: mm/[in].)
22,0
[0.87]
26,0
[1.02]
9,5
[0.37]
5,35 DIA.
[0.21]
37
[1.46]
55
[2.17]
5,9
[0.23]
8,3
[0.33]
15,50 DIA.
[0.61]
4,60
[0.18]
13,8
[0.54]
15,6
[0.61]
4,12
[0.16]
25
[0.98]
36,4
[1.43]
0
A
C
B
Pin 1
Pin 2
Pin 3
2,0 DIA.
[0.078]
6 DIA.
[0.24]
32,0 DIA.
[1.25]
0
/2
0
/2
RTYXXXXXXXX
YYDDMMSSSS
A = Left output: 0.5 Vdc
B = Zero reference
C = Right output: 4.5 Vdc
Pinout
N
(North
American)
E
(European)
Pin 1 = VCC
Pin 2 = GND
Pin 3 = Output
Pin 1 = GND
Pin 2 = VCC
Pin 3 = Output
NOTICE
Ferrous or magnetic material
within a 75 mm [2.95 in] radius
from sensor center may affect
sensor performance.
Figure 2. Functional Characteristics
Sensing Angle
Linearity
Error
1
Accuracy
Error
2
Output Voltage (Vdc)
Actuator Position (°)
0.5
2.5
4.5
-25
-30
-35
-45
-60
-90
-135
+25
+30
+35
+45
+60
+90
+135
0
0
0
0
0
0
0
0.0
A
B C
Clamp High
Clamp Low
Notes:
1. The linearity error is the
deviation of the measured
value from the best fit line
and is the quotient of the
measured output ratio
deviation from the best fit
line at the measured
temperature to the best fit
line output ratio span at the
measured temperature.
2. Accuracy is measured as a
deviation from the index line,
where the index line is
defined as the line with the
ideal slope and sensor
output voltage corrected at
0º position for its ideal value
at 25 °C ±5 °C. Accuracy is
valid only when the sensor
output is correct at 0º
position for its ideal value in
the application.
50° (±25°)
±1.0%
±1.6%
60° (±30°)
70° (±35°)
90° (±45°)
120° (±60°)
180° (±90°)
270° (±135°)
360° (±180°)
Output Voltage (Vdc)
Actuator Position (°)
0.5
2.5
4.5
-180 +180
0
0.0
A
B C