Data Sheet
RTY Series
Sensing range
50° (±25°), 60° (±30°), 70° (±35°), 90° (±45°), 120° (±60°), 180° (±90°),
270° (±135°), 360° (±180°)
Redundant version no
Input voltage
low voltage: 5 Vdc ±0.5 Vdc
high voltage: 10 Vdc to 30 Vdc
Output
low voltage: 0.5 V to 4.5 V ratiometric
high voltage: 0.5 V to 4.5 V non-ratiometric
Input current
low voltage: 20 mA max.; during output to ground short, 25 mA max.
high voltage: 32 mA max.; during output to ground short, 47 mA max.
Operating temperature range -40 °C to 125 °C [-40 °F to 257 °F]
Connector AMP super seal
Life 35 M cycles
EMI/EMC
• EMI radiated immunity: 100 V/m from 200 MHz to 1000 MHz per ISO11452-2
• EMI conducted immunity:
- low voltage: 100 mA BCI per ISO11452-4 from 1 MHz to 200 MHz
- high voltage: 100 mA BCI per ISO11452-4 from 1 MHz to 400 MHz
• EMC: exceeds CE requirements
Housing material PBT plastic
Dimensions 55 mm L x 43 mm W x 41 mm H [2.17 in L x 1.69 in W x 1.61 in H]
Hall-Effect Rotary Position Sensors Line Guide
Hall-Effect Rotary
Position Sensors
2 www.honeywell.com/sensing
More are turning to
Honeywell, for more value.
Honeywell S&C RTY and
RPN Series Hall-effect rotary
position sensors respond
to the presence or to the
interruption of a magnetic
field, using a solid-state
Hall-effect IC to sense rotary
movement of the actuator
shaft and then producing a
proportional output. The IC,
circuitry and magnets are
galvanized with an integral
connector — more than a
match for the most unforgiving
conditions. The HRS100 Series
uses magnetically-coupled
technology in place of a
mechanical wiper assembly
which provides long life and
a cost-effective solution for
harsh environments.
These sensors are often ideal
for potential transportation
applications, such as throttle
and speed position and
control, inboard lever control,
foot pedal, gearshift, steering,
lever, linkage, seat, mirror, tilt
and manipulator arm position.
Other benefits include:
360-degree operating range
with multi-turn allowable
rotation, low torque actuation
and greatly reduced wear-
out mechanisms, enhanced
resistance to damage from
incorrect wiring and electrical
noise, wide operating
angle tolerant to overtravel,
integrated reverse polarity,
short circuit and EMC
protection.