Data Sheet

2 sensing.honeywell.com
Transportation
Aerial work lift platform, front end loader and
digger/excavator boom position
Scissor lift position
Refuse truck lift and automatic reach arm position
Mobile crane steering
Timber harvester/processor equipment cutter arm angle
On-board loader weighing system position
Industrial
Telescoping conveyor elevation
Power generation contact angle
Rail-road crossing arms position
Military
Remote weapon systems elevation
Chassis suspension systems position height
Military vehicle door position
Aerospace:
Ground-based solar panels elevation and azimuth
Ground-based satellite dish elevation and azimuth
Medical:
Robotically-assisted surgery equipment position
Patient bed elevation
For more information on these potential applications, please
see the application note SMART Position Sensor, 100 and
180 Arc Configurations”.
Table 1. Specifications
Component
Parameter
100 Arc
180 Arc
SPS-A100D-
HAMS
SPS-A100D-
VAMS
SPS-A100D-
HAWS
SPS-A100X-
LAAS0401
SPS-A180D-
HAMS
SPS-A180D-
VAMS
sensor
only
0 to 100
0 to 180
inside
outside
inside
0.06
0.11
6 Vdc
to 24 Vdc
18 Vdc
to 40 Vdc
6 Vdc
to 24 Vdc
5 Vdc
6 Vdc
to 24 Vdc
18 Vdc
to 40 Vdc
0.5 Vdc to 4.5 Vdc (10% to 90% of 5 Vdc)
45 mA max.
30 mA max.
45 mA max.
±0.4% full scale output
26.4 Vdc
40 Vdc
26.4 Vdc
N/A
26.4 Vdc
40 Vdc
40 mV/ ±4% FS
22.22 mV/ ±4% FS
312 Hz typ.
4-pin M12 connector
18 AWG
flying leads
Ampseal 16
connector
(p/n 776536)
4-pin M12 connector
sensor
and
magnet
actuator
-40 °C to 85 °C [-40 °F to 185 °F]
-40 °C to 150 °C [-40 °F to 302 °F]
7,8 ±2,5 mm
[0.307 ±0.098 in]
9,2 ±2,5 mm
[0.36 ±0.09 in]
8,58 ±2,5 mm
[0.338 ±0.098 in]
IP67, IP69K
50 G half sine wave with 11 ms duration
20 G from 10 Hz to 2000 Hz
thermoplastic
CE
M6 or 1/4-20
6 N m to 8 N m [53.1 in lb to 70.8 in lb]
magnet
actuator
only
neodymium
10,000 Gauss
Notes:
Tolerance applies for full sense range.
Device used to read analog output must have input impedance greater than 1 MOhm.
The output voltage outside of the valid measurement range will be indeterminate.
Percent linearity is the quotient of the measured output deviation from the best fit line at
the measured temperature to the full scale output span.
Mating connector: 776536-1.
NOTICE
Ferrous metal within a 100 mm [3.9 in]
radius of the magnet may affect sensor