Data Sheet
4 www.honeywell.com/sensing
NOTICE
Stationary ferrous material often creates an initial offset upon installation. If the stationary ferrous material never moves in
relation to the sensor after the installation, and the environment remains ferrous-free, performance should be repeatable. Ensure
the sensor is tested in the application.
Figure 3. Assembly Tools
One Piece (SPS-AUX-AS100-1)
Two Piece (SPS-AUX-AS100-2)
5,00
[0.20]
17,00
[0.67]
25,400 DIA.
[1.0000]
5,00
[0.20]
40,00 DIA.
[1.57]
17,00
[0.67]
25,4 DIA.
[1.00]
NOTICE
ASSEMBLY TOOL
USE
Honeywell recommends
using an assembly tool
to help align the
magnetic axis of rotation
to the inside diameter of
the Sensor.
Assembly Tool Use
1. Place the sensor over the shaft with its epoxy side
facing the mating surface of the mounting plate.
2. Loosely assemble the mounting screws in the
sensor.
3. Install the assembly tool on the shaft.
4. Push the assembly tool into the rotary sensor to
center on the shaft.
5. Tighten the sensor mounting screws while
maintaining pressure on the assembly tool.
6. Remove the assembly tool.
Mounting plate
Assembly tool
Shaft
Sensor
Mounting Screws