Data Sheet

2 www.honeywell.com/sensing
POTENTIAL APPLICATIONS
Medical:
- Airflow monitors
- Anesthesia machines
- Blood analysis machines
- Gas chromatography
- Gas flow instrumentation
- Kidney dialysis machines
- Oxygen concentrators
- Pneumatic controls
- Respiratory machines
- Sleep apnea equipment
- Ventilators
Industrial:
- Barometry
- Flow calibrators
- Gas chromatography
- Gas flow instrumentation
- HVAC
- Life sciences
- Pneumatic controls
Table 1. Absolute Maximum Ratings
1
Parameter
Min.
Max.
Unit
Supply voltage (Vsupply)
-0.3
6.0
Vdc
Voltage on any pin
-0.3
Vsupply + 0.3
V
ESD susceptibility (human body model)
3
-
kV
Storage temperature
-40 [-40]
85 [185]
°C [°F]
Soldering time and temperature:
Lead solder (SIP, DIP)
Peak reflow (SMT)
4 s max. at 250 °C [482 °F]
15 s max. at 250 °C [482 °F]
Table 2. Operating Specifications
Parameter
Typ.
Max.
Unit
Supply voltage (Vsupply)
2
:
3.3 Vdc
5.0 Vdc
Sensors are either 3.3 Vdc or 5.0 Vdc based on listing selected.
3.3
3
5.0
3
3.6
5.25
Vdc
Supply current:
3.3 Vdc supply
5.0 Vdc supply
1.6
2
2.1
3
mA
Compensated temperature range
4
-
85 [185]
°C [°F]
Operating temperature range
5
-
85 [185]
°C [°F]
Startup time (power up to data ready)
-
5
ms
Response time
1
-
ms
Upper output clipping limit
-
97.5
%Vsupply
Lower output clipping limit
-
-
%Vsupply
Accuracy
6
-
±0.25
%FSS BFSL
Total error band
7
-
±2
%FSS
8
Output resolution
-
-
%FSS
8