Service Manual 6 - 79
FIGURE 6-18 Verification pin compensation, example
6.5.2.7 Errors and Warnings
The status code of the [Primary value] or the [Secondary value] can display
an error (status =
<BAD>) or a warning (status = <UNCERTAIN>).
Most common error messages are:
6.5.2.8 Additional Information
Following information can be extracted from the TII-XR system:
Message Cause
Radar max safe fill not set error
[Maximum safe fill] still set to 0 (zero)
Radar max safe fill out of range
[Maximum safe fill] value too high
Entity Description
[DSP firmware version] Besides a generic processor, the TII-XR has a
Digital Signal Processor for algorithm
calculations. See also FIGURE 6-6.
[Production date] Production date of the complete SmartRadar
FlexConn system.
[ART2A serial number] The serial number of the high-frequency module.
This module does all measurements.
[Device serial number] Serial number of the complete SmartRadar
FlexConn system.
[Antenna serial number] Serial number of the measuring antenna.