User Manual

Safety
SmartRadar FlexLine Part No.: 4417.762_Rev07
2 - 6 Service Manual
SmartView: KEMA 07ATEX0011X and IECEX KEM 07.0004 X.
SmartConn: KEMA 07ATEX0093 and IECEX KEM 07.0031.
Without SmartView: Ex d [ia] T6 Ta: -40 °C - +65 °C.
With SmartView: Ex d [ia] ia T4 Ta: -25 °C - +65 °C.
FM [including OneWireless option]
Without SmartView:
Class I DIV I group C,D T6 NEMA 4X Ta: -40 °C - +65 °C.
With SmartView:
Class I DIV I group C,D T4 NEMA 4X Ta: -25 °C - +65 °C.
CSA [pending for OneWireless option]
Without SmartView:
Class I DIV I group C,D T6 NEMA 4X Ta: -40 °C - +65 °C.
With SmartView:
Class I DIV I group C,D T4 NEMA 4X Ta: -25 °C - +65 °C.
2.9.2 Explosion Safety - With SmartConn
Type of protection:
ATEX / IEC Ex / CSA [pending for OneWireless option]
Without SmartView: Ex de [ia] T6 Ta: -40 °C - +65 °C.
With SmartView: Ex de [ia] ia T4 Ta: -25 °C - +65 °C.
2.9.3 Compliance to FCC, R&TTE, IC
This device complies with EN 302372 of the R&TTE Directive, Part 15
of the FCC Rules, and RSS-Gen of IC. The device does not cause
harmful interference and accepts any interference received.
WARNING! Changes or modifications made to this equipment
not approved by Enraf B.V. invalidate the R&TTE/
FCC/IC authorization to operate this equipment.
CAUTION! This equipment has been tested. It complies with a
Field disturbance sensor device, pursuant to Part 15
of the FCC Rules and FCC-Gen for IC. Operation is
subject to the following two conditions: (1) this device
may not cause interference, and (2) this device must
accept any interference, including interference that
may cause undesired operation of the device. These
limits are designed to provide reasonable protection
against harmful interference in a residential instal-
lation. This device generates, uses and radiates
radio frequency energy. If this device is not installed
and used in accordance with the instructions, it can
cause harmful interference to radio communications.
However, there is no guarantee that interference will
not occur in a particular installation.
NOTE: This device is certified to measure liquid levels in
metal, concrete or similar materials, enclosed tanks.
2.9.3 Compliance to radio communication equipment approvals
2.9.3.1 R&TTE (Radio & Telecommunication Terminal Equipment)
This device complies with EN 302372 of the R&TTE Directive
The device does not cause harmful interference and accepts any interference received.
WARNING! Changes or modifications made to this equipment not approved by Enraf B.V.
invalidate the R&TTE
2.9.3.2 FCC (Federal Communication Commission)
FCC information:
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1. This device may not cause harmful interference, and 2. This device must accept any
interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the
following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
--Consult the dealer or an experienced radio/TV technician for help.