User Manual

Commissioning
SmartRadar FlexLine Part No.: 4417.762_Rev07
6 - 144 Service Manual
RTD 3 spots (see FIGURE 6-37 left side)
Multi RTD probe (see FIGURE 6-37 right side)
Name Explanation Value Range Default
[Element type] The supported element
type is: SPL
3 characters
<SPL>
<--->
[Number of elements]
The number of elements a
RTD probe has
<1 .. 3> <0>
[Lowest element offset]
The distance from tank zero
till the lowest position of the
multi-RTD probe.
So not used for the 3-wire
version and it must be 0.
floating point number:
<-x.x .. +x.x>
MUST BE <0.0>
<80.0>
[RTD element positions] The positions of the RTDs
from tank zero level
3 floating point numbers:
<-x.x .. +x.x>
Note: Only actually used
elements to be entered.
<0,0,0>
Name Explanation Value Range Default
[Element type] The supported element
type is : SPL
3 characters
<SPL>
<--->
[Number of elements]
The number of elements a
RTD probe has
<1 .. 14> <0>
[Lowest element offset]
The distance from tank zero
till the lowest position of the
multi-RTD probe
floating point number:
<-x.x .. +x.x>
<80.0>
[RTD element positions]
The positions of the RTDs
from the lowest position of
the probe.
So not tank zero level!
14 floating point numbers:
<-x.x .. +x.x>
Note: Only actually used
elements to be entered.
<0,0,0,0,0,0,0,0,0,0,0,0,0,0>