User Manual

Commissioning
Part No.: 4417.762_Rev07 SmartRadar FlexLine
Service Manual 6 - 11
A changeover is done by the protocol switch.
Protocol switching is bound to the following:
Engauge only supports GPU-FlexConn to Modbus switching.
Once the HCI-GPU is in Modbus mode, Engauge cannot execute
any modifications as Engauge does NOT support Modbus communi-
cation.
This scenario may be found at a first-time installation or during
servicing issues.
SmartView supports both GPU-FlexConn to Modbus and Modbus to
GPU-FlexConn switching at any time, the actual protocol type being
visible real time.
Suitable on issues in the field.
Along with data monitoring the Modbus host can issue certain
commands such as Overfill test, Reset, Alarm Test, and Modbus to
GPU-FlexConn switching.
It is recommended to disconnect the SmartRadar FlexLine from the
Modbus communication link when using Engauge with the GPU-
FlexConn protocol.
Example (with ModTest screen example of Daniel Europe Ltd. below):
To switch from Modbus to GPU-FlexConn, the following must be done:
Set Function = 5; Address = 1; Value = 1.
Activate by pressing the Poll button.
Using ... Switching possible from ...
Engauge GPU-FlexConn --> Modbus
SmartView GPU-FlexConn --> Modbus
Modbus --> GPU-FlexConn
Modbus command Modbus --> GPU-FlexConn