CHECK EQUIPMENT FOR CORRECT OPERATION
HZ221 or HZ311 panels
Call for heat or cool from each zone individually. Verify the equipment comes on and dampers go to correct posi-
tion. Verify CPRD relief damper is adjusted correctly (see "Setting the Regulator" on page 7).
HZ322 or HZ432 panels
From the home mode, press mode button twice to enter 
checkout mode on zone panel. In checkout mode you 
can:
1  Test every heat stage.
2  Test every cool stage.
3  Test emergency heat operation (if zone panel is con-
figured for a heat pump with aux heat).
4  Open and close each zone damper.
After checkout mode you should make a call for heat or cool from each thermostat to verify correct communication 
to the zone panel. Also, verify CPRD relief damper is adjusted correctly (see "Setting the Regulator" on page 7).
HOME
MODE
BACK NEXT
CONFIG
CHECK OUT
ADJUST SETTING
M28194