Installation Sheet

PLUMBING
Water Supply and Drain Connections
STEP ONE: Connect the Water Supply
Use hot or cold water.
Cut the water line so it reaches from the humidier to
the main water supply tap.
Insert the water line into the gray quick connect
tting. Insert it fully, and apply modest pull pressure to
ensure a tight t.
Note: The quick connect tting can be removed if you
prefer to use a standard 1/4-in. brass compression nut
plumbing connection. Do not remove the lter if you
select this option.
STEP TWO: Tap into a Water Line
Consult local codes for proper plumbing.
Use the saddle valve provided or a T-tting and
manual shutoff valve to tap into the water line.
Refer to the literature included with the valve you
chose and the local plumbing codes. Use proper
technique for the valve.
Connect the other end of the humidier water line
to the water valve.
MCR32931A
Saddle Valve
T-fitting
Water Supply
Line
Manual Shutoff
Valve
M29605
2
1
3
Humidier 69-2413EF—17
11