Installation Sheet

MOUNTING
STEP THREE: Congure Humidier Bypass
Congure the humidier bypass outlet to the side that
best ts the application.
If the bypass needs to be on the other side, remove
the top and bottom covers.
Unplug the damper wire and plug in on the other side
(HE150/HE250 only).
Pull the bypass clamps apart from center to remove
the bypass; snap it back into place with the outlet on
the desired side.
Ensure that the pad is accessible. The handle of the
pad holder and side panel of the humidier can be
switched so the pad holder can be removed (opposite
side of the bypass duct opening).
To remove the handle for the pad holder, slide it
toward the back of the humidier, then pull it away
from the humidier.
To remove the opposite side panel, place a
screwdriver into the two slots on the back of the
humidier, and pop the panel off.
Snap the pad holder handle and side panel back into
place in the desired conguration.
MCR29875
If you are installing HE300 Fan model, proceed to page 10.
Bypass Model Installation
MCR29876
1
1
2
2
3
3
MCR29946
4
5
Humidier 69-2413EF—17
7